技术参数
加入对比温度计
| 测量原理 | Thermocouple |
| 特性 / 应用 | Industrial 美国样式模块化温度组件法兰式过程连接带加长含 保护套管 |
| 保护套管 | bar stock (drilled) |
| 芯子 / 探头 | 矿物绝缘 (MI), 柔性 |
| 保护套管外径 / 芯子 | 3/4'' (19,05 mm) 7/8'' (22,23 mm) 17/16'' (26,99 mm) |
| 最大插入深度(按需) | 高达 24'' (609 mm) others 按需 |
| 保护套管材质 | 316/316L others 按需 |
| 可选涂层 | 可选按需 |
| 过程连接 | 法兰: ASME 1" 150 RF (B16.5) ASME 1" 300 RF (B16.5) ASME 1" 600 RF (B16.5) ASME 1" 900/1500 RF (B16.5) ASME 1.5" 150 RF (B16.5) ASME 1.5" 300 RF (B16.5) ASME 1.5" 600 RF (B16.5) ASME 1.5" 900/1500 RF (B16.5) ASME 2" 150 RF (B16.5) ASME 2" 300 RF (B16.5) ASME 2" 600 RF (B16.5) ASME 2" 900/1500 RF (B16.5) ASME 3" 150 RF (B16.5) ASME 3" 300 RF (B16.5) ASME 3" 600 RF (B16.5) ASME 3" 900/1500 RF (B16.5) |
| 端部形状 | 直形锥形 |
| 表面粗糙度 Ra | 1,6 μm (63,0 μ内.) |
| 工作温度范围 | 类型 T: -270 °C ...400 °C (-454 °F ...752 °F) 类型 J: -210 °C ... 1.200 °C (-346 °F ...2.192 °F) 类型 E: -270 °C ... 1.000 °C (-454 °F ...1.832 °F) 类型 K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) 类型 N: -270 °C ... 1.300 °C (-454 °F ...2.372 °F) |
| 最大过程压力(静压) | 在 20°C: 500 bar (7252 psi) depends 在配置 |
| 测量精度 | 标准符合 ASTM E-230 特殊符合 ASTM E-230 |
| 响应时间 | 取决于配置 63% rt = 15,0 s |
| 一体化表头变送器 | 是 (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| 防爆认证 | 变送器仅 FM 是 CSA 是 FM/CSA 是 |
| 认证 | SIL (变送器仅) |
高度模块化温度计,适用于恶劣工况中的许多应用,例如:电厂、炼油厂、化工或石化行业。坚固耐用的温度计采用棒材热保护套管、带法兰连接,与不同型号的模块化变送器配套使用,组成完整测量单元,可以直接测量,具有高测量精度和可靠性。提供多种过程连接、外形尺寸和材料,例如:SS316、INCONEL600、HastelloyC276合金、钛或蒙乃尔,使用灵活。
优势
-
一站式温度测量解决方案。内置传感器的一流变送器,适用于苛刻工业过程应用。
-
拆箱后直接安装使用
-
安装在大多数设备上均能提升电气隔离性能(2 kV)
-
简单的模块化结构:性价比高。 订购和重新订购简单。包含传感器、热保护套管和变送器的整体单元提供完整测量点解决方案
-
所有iTEMP®变送器的长期稳定性均≤ 0.05 % /年
应用领域
-
TH54是热电偶(TC)温度计,安装在热保护套管中,结构坚固,适用于各种工业过程,包括恶劣工况。由氧化镁绝缘热电偶测量探头和棒材热保护套管组成。
-
传感器适用于下列过程行业:化工行业
-
石化行业
-
电厂
-
炼油厂
-
海上平台
附件 / 备件 41
共 41 项备件 · 点击收起
| 订货号 | 名称 / 说明 | |
|---|---|---|
| TA30H- | 接线盒 TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing). | 询价 |
| 71182606 | 密封5x O-ring 57x2.5 5x O-ring 64.3x1.8 blau | 查看详情 |
| XPT0004- | Spare Parts Kit Cover TA30Rcover of connecting head | 询价 |
| TA30R- | 接线盒 TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight. | 询价 |
| FXA195- | 通讯接口 FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | 询价 |
| TID10- | 温度变送器显示器TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84. | 询价 |
| 71044062 | 设备包2x screws, 1x sealing CDI-connector | 查看详情 |
| TMT82- | 温度变送器 TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | 询价 |
| TMT84- | 温度变送器 TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | 询价 |
| TMT85- | 温度变送器 TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | 询价 |
| TMT86- | 温度变送器 TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive. | 询价 |
| 51004948 | 面盖插销Screw, washer, spring washer | 查看详情 |
| 51006845 | 缆塞Cable gland NPT 1/2, D4-8.5, IP68 | 查看详情 |
| TMT142E- | 电子模块 TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | 询价 |
| TMT142G- | 外壳 TMT142GHousing TMT142G | 询价 |
| TMT142X- | 备件 TMT142XSpare parts TMT142X | 询价 |
| TMT142E- | 电子模块 TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | 询价 |
| TMT142G- | 外壳 TMT142GHousing TMT142G | 询价 |
| TMT142X- | 备件 TMT142XSpare parts TMT142X | 询价 |
| 51007995 | 安装支架Mounting bracket SS316L, tube 1,5-3" | 查看详情 |
型号配置 / 参数对比
来源:Endress+Hauser网站公开信息
服务案例
市政污水处理 · 热电偶应用案例
项目背景
城市污水处理厂的进水、生化与出水工段。本次项目围绕热电偶展开,要解决的核心问题是:以热电偶测量高温工况温度。
工况挑战
现场介质与工况的特点是污水中含固率高、含腐蚀性组分,昼夜水量波动大,而且出水指标波动、探头易被污泥与生物膜覆盖。因此热电偶不能照搬通用配置,按温度上限、气氛与响应速度选分度号。
解决方案
阿仪科技技术团队按温度测量的方式推进:按测温点位置与响应要求做温度方案。配置上按温度上限、气氛与响应速度选分度号,并同步对照:出水须稳定达到一级 A 标准并联网上传数据。
实施效果
投运后系统运行稳定,实际效果是:耐高温能力强,炉窑温度可直接测。
食品饮料 · 热电偶应用案例
项目概况
项目现场在配料、杀菌、灌装与 CIP 清洗工段。客户希望在既有装置上完善热电偶配置,核心诉求是以热电偶测量高温工况温度。
技术难点
真正麻烦的是:介质多为糖浆、乳品与饮料等易结垢物料,卫生级要求高,并且清洗频繁,仪表必须耐受 CIP/SIP 高温碱洗。这些都要求热电偶在配置时按温度上限、气氛与响应速度选分度号。
配置方案
按温度测量组织供货与实施:按测温点位置与响应要求做温度方案。现场按温度上限、气氛与响应速度选分度号,并逐条核对:须满足食品安全与卫生级(3-A / EHEDG)要求。
投运表现
完成调试后,耐高温能力强,炉窑温度可直接测,测量数据可直接用于工艺调整与考核。
化工制药 · 热电偶应用案例
现场工况
该客户属于化工制药行业,生产装置位于反应釜、计量罐与成品储罐区。项目的主要任务就是以热电偶测量高温工况温度。
需要解决的问题
难点在于介质腐蚀性强、常带溶剂与结晶,部分区域为爆炸性环境;与此同时强腐蚀与防爆双重约束,仪表寿命短、停机维护成本高。选型上必须按温度上限、气氛与响应速度选分度号。
我们的做法
我们采用温度测量的交付思路 — 按测温点位置与响应要求做温度方案。实施时按温度上限、气氛与响应速度选分度号,同时逐项校验:需满足防爆认证与 GMP 数据可追溯要求。
运行结果
系统投运以来表现稳定,日常维护量明显减少 — 耐高温能力强,炉窑温度可直接测。
电力能源 · 热电偶应用案例
应用背景
锅炉给水、汽机凝结水与脱硫脱硝系统是电力能源行业的典型工况。项目以热电偶为切入点,重点是以热电偶测量高温工况温度。
工况约束
高温高压下测量漂移,非计划停机代价极高,而高温高压,蒸汽与含盐水并存的条件又进一步放大了这一点。因此热电偶必须按温度上限、气氛与响应速度选分度号。
交付方案
交付按温度测量来组织 — 按测温点位置与响应要求做温度方案。实施中按温度上限、气氛与响应速度选分度号,同时满足需满足电力行业规程与机组可用率指标。
使用效果
运行结果表明:耐高温能力强,炉窑温度可直接测,该测点的测量置信度明显提高。