Nr Order Number Specifications
34 71108602 I/O Modules
Non-Ex, Ex.
Current output, 4-20mA HART 4-20mA
analog.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
71128617 Overvoltage protector
4-20mA HART.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
71128619 Overvoltage protector
4-20mA HART, PROFIBUS PA, FOUNDATION
Fieldbus, Imp./Freq./Switch output.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
71197334 transmitter FHX50
Consists:
electronics, ribbon cable.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass200, Prowirl 200
Promag 200, Prosonic Flow 200.
71296840 Plug M12, VA
To connect FHX50.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Not for dust Ex.
Usage: Prowirl 200, Promass 200
Promag 200, Prosonic Flow 200.
30 XPD0002- Ultrasonic Flowmeter Electronic Plug-in 200
Main electronic module
A
2
75
76
71206552 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71206554 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71206555 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
34 XPD0015- I/O Modules 2-wire, 4-20mA, HART, Ex
Non-Ex, Ex.
1x current output HART.
A
A
00
71206556 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
37 71110280 Terminal Kit 2-Wiring, I/O Modules
Consists:
4x terminal 2-pole, green.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
34 XPD0016- I/O Module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex.
1x current output HART.
1x PFS= pulse/freq./switch output.
A
B
00
34 XPD0018- input and output module
Non-Ex, Ex.
1x current output HART.
1x PFS= pulse/freq./switch output.
1x current input.
A
D
00
40 XPD0024- Display Module
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
t-mass 150, Promag 200, Prowirl 200.
Consists:
Display SD02, helix cable
ribbon cable, connector cover.
A
C
00
40 XPD0025- Display Module
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
Promag 200, Prowirl 200.
Consists:
Display SD03 illuminated, ribbon cable
connector cover.
A
E
00
20 71110281 aluminum cover
Material: 316L.
O-ring, EPDM, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
20 71110282 aluminum cover
Material: 316L.
O-ring NBR, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67, FHX50.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110291 aluminum cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110284 aluminum cover
Material: 316L.
O-ring EPDM /PTFE coated.
Usage: terminal compartment Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71185516 Cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMP54/FMP56/FMP57, FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Prowirl 200.
20 71110299 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
20 71110297 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71110301 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71110302 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71185517 aluminum cover
Material: aluminium.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
15 50103658 cable plug
15 50098036 explosion-proof cable plug
Kit 10 cable glands M20x1.5 Ex
15 71069285 Cable Plug Assembly
15 50098041 Adapter
Kit 10 extension M20x1.5/G 1/2"
15 71115505 M20x1.5/G 1/2 "adapter
15 50098042 Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15 71115509 M20x1,5/NPT1/2 "adapter
65 71110303 Enclosure Seal Kit
Consists:
O-ring 88.5x3.53 EPDM/PTFE
cover electronics compartment
housing GT19.
O-Ring 88.5x3.53 NBR
cover electronics compartment
housing GT18, GT20.
O-ring 91.67x3.53 EPDM/PTFE
cover terminal compartment
housing GT19.
O-Ring 91.67x3.53 NBR
cover terminal compartment
housing GT18, GT20.
O-ring 50.39x3.53 EPDM/PTFE
housing/sensor.
FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
19 71115174 housing filter plug 316L, GT18, 1 group
Consists:
2x filter plug metall 316L.
1x pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
19 71115175 Housing Filter Plug (Brass/Nickel)
Consists:
2x filter plug brass nickel
pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
17 71115176 Housing Set Clips
Usage: housing GT18/GT19/GT20
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
71162242 Cover | GT18/GT19/GT 20,316L
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/
FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200, Prowirl
200.
9B2BXX- transmitter ultrasonic flow meter Flow B 200, 9B2BXX
AA
BJ
BK
C2
C3
C4
IJ
IK
JK
MJ
MK
NF
NJ
UJ
UK
UR
9
A
B
C
D
9
A
C
E
L
M
9
C
S
6
9
A
B
C
D
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AQ
AR
E9
EA
EB
I7
K9
N9
NA
P9
PB
75
76
Z1
Z2
53 XPD0003- Ultrasonic Flowmeter Sensor Cable Plug B
Sensor cable set / Cable gland set
1
2
3
4
5
6
A
B
C
D
E
51 XPD0004- US Transducer, tools, Prosonic Flow B
Ultrasonic transducer
Sensor seal
Hot swap tool
1
2
3
A
B
1
2
3
4
DK7ST- Flow Equalizer DK7ST
-200oC... 400oC / -330... 750oF
1F
1H
2H
50
80
9
A
B
K
0
1
9
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
CA
IA
MA
NA
UA
UR
1