Nr Order Number Specifications
A 50104751 PCB Main Board
A 50104752 PMAG10 Motherboard
A 71098237 PCB Main Board
HE = harsh environment
A 71098239 PCB Main Board
HE = harsh environment
3 50104749 Fuse
3 50104750 Fuse
B 50104745 10/91W display module with press keyboard
C 50104754 Terminal
C 71098240 Junction Module
HE = harsh environment
D 50098018 Sensor Part Terminal
Usage:
10/50/51/53/55/400/800
D 71039497 Sensor Part Terminal
Usage:
10/50/53/55
HE = harsh environment
1 50108138 10/91W wiring block
Kit Terminal Block 10/91W
13 50094038 wiring chamber cover
10/5X/40/8X/93/65/92F
13 71247838 service cover, detached
Usage:
10/5X/8X/8DF/8CN/92F/65/400/800
acc. service info SI01351D-1/06
Consists:
Cover Rep.kit for G14
O-Ring 110.00 x 4.50 HNBR, Grease
9 50094038 wiring chamber cover
10/5X/40/8X/93/65/92F
5 50104746 cover with glass window
6 50104747 blind meter cover
10 50103658 cable gland
10 50096840 10 M20x1,5 cable plugs
Kit 10 cable glands M20x1,5
10 50098041 M20x1.5/G 1/2 "adapter
Kit 10 extension M20x1.5/G 1/2"
10 50098042 M20x1.5/NPT 1/2 "Adapter
Kit 10 extension M20x1.5/NPT 1/2"
4 50104748 display module carrier board 10/91W
7 50104753 cover sealing ring
8 50097147 Ground strap/lid locking buckle
10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM
2 50099102 cast aluminum/stainless steel housing sleeve
15 50098019 mounting screws and mounting accessories
Usage:
10/50/51/53/55/400/800
Sensor: D/E/H/L/P/S/W
12 50098020 mounting screws and mounting accessories
Usage:
10/23/50/51/53/55
Sensor: D/E/H/L/P/S/W
14 50098023 Washer
Usage:
10/50/51/53/55/400/800
Sensor: D/E/L/P/S/W
11 50098024 Washer
Usage:
10/23/50/51/53/55
Sensor: D/E/L/P/S/W
10XXX- Promag 10 Transmitter 10XXX
electromagnetic flowmeter
Application:
XXX Promag 10W, 10P, 10H, 10D, 10L, 10E
Version:
XX Transmitter only
Approval:
A Non-hazardous area
R FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
Housing:
A Compact Alu, IP67 NEMA4X
G Field Alu, IP67 NEMA4X
P Compact Alu, IP67 NEMA4X, HE HE= harsh environment
T Field Alu, IP67 NEMA4X, HE HE= harsh environment
Cable, Remote Version:
0 Not used
2 10m/30ft coil and signal cable
4 ..... m coil and signal cable
5 ..... ft coil and signal cable
Cable Entry:
A Gland M20
B Thread NPT 1/2
C Thread G 1/2
Power Supply; Display:
0 85-250VAC; w/o display, Remote configuration
1 20-28VAC / 11-40VDC; w/o display Remote configuration
4 85-250VAC; 2-line, push buttons
5 20-28VAC / 11-40VDC; 2-line, push buttons
Adjustment; Software Feature:
A Factory setup; basic version
Output, Input:
A 4-20mA HART pulse passive
DK5CA- Promag 10/50/51/53/55 Split Cable DK5CA
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
Cable, Remote Version:
2 10m/30ft
4 ..... m
5 ..... ft
Approval:
A Non-hazardous area ATEX II 3G, FM/CSA
DK5WM- Promag10/50/51/53/55 Transmitter Mounting Assembly DK5WM
10/50/51/53/800
Application:
B Remote, field Tube 3/4 - 3inch
DK5GC- Ground wire DK5GC
A kit includes 2 cables
Nominal Diameter:
15 DN15 1/2"
1F DN150 6"
1H DN100 4"
1Z DN125
25 DN25 1"
2F DN250 10"
2H DN200 8"
32 DN32
3F DN350-DN2000
3H DN300 12"
40 DN40 1-1/2"
50 DN50 2"
65 DN65
80 DN80 3"
Process Connection:
5 PN16, AS4087
7 Table E, AS2129
A PN40 EN1092-1(DIN2501)
B PN25 EN1092-1(DIN2501)
C PN16 EN1092-1(DIN2501)
D PN1016 EN1092-1(DIN2501)
L Cl. 150 ANSI B16.5
M Cl. 300 ANSI B16.5
T 10K JIS B2220
U 20K JIS B2220
DK5GD- grounding ring DK5GD
Includes 1 grounding disc/protection
disc
Nominal Diameter:
15A DN15 1/2 ", 1.4435/316L
15B DN15 1/2", Alloy C- 22
1FA DN150 6 ", 1.4435/316L
1FB DN150 6", Alloy C- 22
1HA DN100 4 ", 1.4435/316L
1HB DN100 4", Alloy C- 22
1ZA DN125, 1.4435/316L
1ZB DN125, Alloy C- 22
25A DN25 1 ", 1.4435/316L
25B DN25 1", Alloy C- 22
2FA DN250 10 ", 1.4435/316L
2FB DN250 10", Alloy C- 22
2HA DN200 8 ", 1.4435/316L
2HB DN200 8", Alloy C- 22
32A DN32, 1.4435/316L
32B DN32, Alloy C- 22
3FA DN350 14 ", 1.4435/316L
3FB DN350 14", Alloy C- 22
3HA DN300 12 ", 1.4435/316L
3HB DN300 12", Alloy C- 22
40A DN40 1 1/2 ", 1.4435/316L
40B DN40 1 1/2", Alloy C- 22
4FA DN450 18 ", 1.4435/316L
4FB DN450 18", Alloy C- 22
4HA DN400 16 ", 1.4435/316L
4HB DN400 16", Alloy C- 22
50A DN50 2 ", 1.4435/316L
50B DN50 2", Alloy C- 22
5HA DN500 20 ", 1.4435/316L
5HB DN500 20", Alloy C- 22
65A DN65, 1.4435/316L
65B DN65, Alloy C- 22
6HA DN600 24 ", 4435/316L
6HB DN600 24", Alloy C- 22
80A DN80 3 ", 1.4435/316L
80B DN80 3", Alloy C- 22
Liner:
9 Special version, TSP-no. to be spec.
E PTFE
Process Connection:
5 PN16, AS4087
7 Table E, AS2129
9 Special version, TSP-no. to be spec.
A PN40 EN1092-1(DIN2501)
B PN25 EN1092-1(DIN2501)
C PN16 EN1092-1(DIN2501)
D PN10 EN1092-1(DIN2501)
L Cl. 150 ANSI B16.5
M Cl. 300 ANSI B16.5
T 10K JIS B2220
U 20K JIS B2220
FXA193- communication interface FXA193
The service interface connects
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
-Serviceinterface with RS 232C
connection cable (9 pin.)
-FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
-Service Softw.ToF Tool-Fieldtool
Package
Approval:
9 Special version, TSP-no. to be spec.
A For use in non-hazardous area
B ATEX II (1) GD
C CSA/FM Class I Div. 1
D ATEX, CSA, FM
Connection Cable:
9 Special version, TSP-no. to be spec.
A Proline device
B ToF device
E Proline and ToF device
F Ex two-wire device
G Proline device and Ex two-wire device
H Proline, ToF and Ex two-wire device
X Without connection cable