| TR13 | ||||||
| Order Number | Description | recommend | Tk | Location | group | effective |
| 71249291 | heat transfer oil FDA certification 30g | A | not classified. | |||
| 71312729 | heat transfer oil HSC 340, 100g | A | not classified. | |||
| 71367427 | Gasket Packing unit: 10 pieces | S | not classified. | |||
| 71111513 | ceramic terminal | A | C | Terminal Module | ||
| 71111514 | ceramic terminal | A | C | Terminal Module | ||
| 71111515 | ceramic terminal | A | C | Terminal Module | ||
| 52028179 | Washer Profile gasket for coverStainless steel housing F15 | S | not classified. | |||
| 60017971 | Display Display LC for TA20J | S | not classified. | |||
| 71043745 | Air Compensated Filter Consists of:filter plug plastic,Pressure compensation filter, O-ring.Usage: housing F15.Non Ex. | S | not classified. | |||
| 71044061 | device pack 2x screws, 2x springs, 2x spring rings,1x sealing CDI-connector | S | not classified. | |||
| 71313382 | Connector | S | not classified. | |||
| 71142762 | O-ring | S | not classified. | |||
| TS111- | iTHERM TS111 Core Replaceable.Metric version according DIN43735. | S | A | sensor | ||
| TPR100- | thermal resistance core TPR100 Mineral insulated cable (MgO)Replaceable insert acc.EN60751.max. measuring range: -200...600 oC(depending on configuration) | S | A | sensor | ||
| TA730- | Protective Sleeve TA730 In PTFE, PVDF, Tantalum or Titanium forthermowells **TW13, TR13 and TC13according to DIN Form F.Formula for calculating the totallength:Titanium or Tantalum:TL = U 3mm (0.12in)PTFE:TL = U 15mm (0.6in)PVDF:TL = U 18mm (0.71in) | S | F | Assembly/Armored Accessories | ||
| TW13- | **Protective sleeve TW13 with flange connection.Protection tube acc. DIN 43772 /2F 3Fwelded version. | S | E | Assembly/Armored | ||
| TR88- | **Thermal Resistors TR88 to screw-in. Neck DIN43772.Replaceable insert, MgO.max. measuring range: -200...600 oC(depending on configuration) | S | not classified. | |||
| TA20A- | **junction box TA20A Product being phased out,limited availability.Connection head to mount a measuringinsert with head transmitter or aconnection socket. To be mounted on anarmature or protective sleeve.Material: Aluminium epoxy resin coatingArea temperature : max. 100 oC;ATEX: 95 oC. | S | D | Housing/Housing Accessories | ||
| TA20B- | junction box TA20B Connecting head to mount a measuringinsert with head transmitter or aconnection socket. To be mounted on anarmature or protective sleeve.Material:Polyamid blackAmbient temperature: max. 80 oCProtection: IP65 | S | D | Housing/Housing Accessories | ||
| TA20D- | **junction box TA20D Product Phased Out.Connection head to mount a measuringinsert with up to two head transmittersor a connection socket and one headtransmitter. For mounting on armatureor protection sleeve.Material: Aluminium, varnishedAmbient temperature: max. 100 oC;ATEX: 95 oC. Protection: IP66 | S | D | Housing/Housing Accessories | ||
| TA20R- | **Junction Box TA20R Stainless steel AISI 316LW 1.4404. Max temperature 100 oC,ATEX: 95 oC. Protection class IP66/IP67 | S | D | Housing/Housing Accessories | ||
| TA20W- | **junction box TA20W Product PhasedOut. Connection head ameasuring to mount insert with head transmitteror connection socket. To be mounted onan armature or a protection sleeve.Material: AluminiumArea temperature: max. 100 oC;ATEX: 95 oCProtection: IP66 | S | D | Housing/Housing Accessories | ||
| TA21E- | Junction Box TA21E Retainer for terminal block or headtransmitter.Cover: srewable.Material: Aluminum.Max. temp.: 100 oC; ATEX 95 oC.Protection: IP65. | S | D | Housing/Housing Accessories | ||
| TMT84- | module temperature transmitter TMT84 Dual sensor input.Advanced diagnostics: sensor monitoring.Galvanic isolation 2kV.Application: RTC, TC, Ohm, mV.Current consumption: 11 mA.Mounting: head form B, DIN43729.Factory setup:CH1: Pt100, 3-wire, oCCH2: inactiveDiffering configuration optionalselectable. | S | B | electronic (sensor) | ||
| TMT85- | module temperature transmitter TMT85 Temperature transmitter with dualsensor input and advanced diagnosticsfor sensor monitoring.FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV(sensor input to the output). Application: RTC, TC, Ohm, mV.Current consumption: 11 mA.Mounting: head form B, DIN43729.UL listed, CSA General Purpose. | S | B | electronic (sensor) | ||
| TID10- | temperature transmitter display TID10 to plug on.Dot-Matrix measured value display. 12 DIP-switches buttom side.Settings:FF: Simulation, Write Lock.PA: Bus address, Write Lock.Compatible: TMT85, TMT84. | S | B | electronic (sensor) | ||
| READWIN- | Readwin 2000 Debug Package READWIN Readwin 2000 Operation Read. software | T | not classified. | |||
| TXU10- | instrument debugging package TXU10 is used to set the connection line for PC with USB interface for the device program that can be programmed and debugged by PC. | A | not classified. | |||
| FXA195- | Communication Interface FXA195 Modem to connect HART field devicesto a computer via USB. Commissioning offield devices with software tool.:: To connect to a intrinsically safesignal circuit.:: SIL2, IEC61508. | T | not classified. | |||
| TA30A- | connector TA30A Retainer for terminal block or headtransmitter optional display.Cover: low, optional window.Material: aluminium.Coating: polyester powder-coating. Colour: body blue, cover grey.Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | S | D | Housing/Housing Accessories | ||
| TA30D- | connector TA30D Retainer for 2 head transmitters orterminal blocks.Cover: high, Material: aluminium.Coating: polyester powder-coating. Colour: body blue, cover grey.Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | S | D | Housing/Housing Accessories | ||
| TA30P- | Junction Box TA30P Retainer for 2 head transmitters orterminal blocks.Cover: high, Material: Polyamid PA12 antistatic.Colour: black.Ambient temp.: -40...120oC (housing). Protection: IP65 (housing). | S | D | Housing/Housing Accessories | ||
| TMT180- | module temperature transmitter TMT180 Temperature transmitter,PC-programable.Application: RTD.2-wire 4-20mA.Fault reaction: NAMUR NE 43.Mounting: head form B, DIN EN50446.UL listed. | S | B | electronic (sensor) | ||
| TMT181- | **Module temperature transmitter TMT181 Product being phared out,limited availability.Temperature transmitter,PC-programmable.Application: RTD, TC, Ohm, mV.2-wire 4-20mA, galvanic isolation.Fault reaction: NAMUR NE 43.Mounting: head form B, DIN EN50446.UL listed. | S | B | electronic (sensor) | ||
| TMT182- | **Module temperature transmitter TMT182 Temperature transmitter, Protocol HART.Application: RTD, TC, Ohm, mV.2-wire 4-20mA, SIL2, galvanic isolationFault reaction: NAMUR NE 43.Mounting: head form B, DIN43729.UL listed.GL (German Llyod) Marine. | S | B | electronic (sensor) | ||
| TMT82- | module temperature transmitter TMT82 2-wire temperature transmitter.Dual universal sensor input.Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV.::Highly reliable due to driftdetection and sensor back up.::Optional also for safety criticalapplications by means of SIL 2/3acc. to IEC61508. | S | B | electronic (sensor) | ||
| DIENST- | Services | A | not classified. | |||
| TR13- | **TR13 with flange connection.Thermowell acc. DIN43772/2F 3F.Replaceable insert, MgO.max. measuring range: -200...600 oC.(depending on configuration). | S | not classified. | |||
| XPRFID- | RFID TAG as spare part available onlyfor instruments with option TZD, marking RFID TAG Spare RFID TAG Consists of:RFID TAG, fixing wire, crimp sleeve. | S | not classified. | |||