Nr Order Number Specifications
71249291 heat conduction oil FDA certification 30g
71312729 heat transfer oil HSC 340, 100g
C 71111513 ceramic terminal
C 71111514 ceramic terminal
C 71111515 ceramic terminal
71044061 Equipment Package
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector
A TPR100- thermal resistance core TPR100
Mineral insulated cable (MgO)
Replaceable insert acc.EN60751.
max. measuring range: -200...600 oC
(depending on configuration)
3
A
G
H
J
P
U
V
XX
YY
1
2
C
F
3
7
A
B
C
D
F
G
H
P
Y
0
0
0
A TPR300- thermal resistance core TPR300
Replaceable insert (MgO) to use
TR6x line.
max. measuring range: -200...600 oC
(depending on configuration)
X
Y
1
3
9
C
F
2
3
6
7
A
B
C
D
F
G
Y
0
0
0
E TW10- **Protective Sleeve TW10
screw in, Protection tube acc.
DIN 43772 /2G 3G, welded version.
2
A
B
D
E
F
G
H
Y
1
2
3
4
8
9
BG
BH
BJ
BK
BM
CA
CB
CC
CD
CE
HD
HH
JA
JB
JC
M
R
S
T
W
Y
5
6
7
A
C
R
S
X
Y
0
1
0
E TW11- **Protective Sleeve TW11
to screw in
Pipe-version, welded
DIN 43772 / 2G 3G
2
A
B
D
E
F
Y
BG
BH
BK
CA
CB
CD
CE
JA
JB
JC
M
R
S
T
W
Y
3
5
6
7
S
U
X
Y
0
1
0
E TW12- **Protective Sleeve TW12
screw in, Protection tube acc.
DIN 43772 /2 3, without neck
welded version.
2
A
B
D
E
F
Y
1
2
3
4
A
B
C
E
F
M
R
S
T
W
Y
I
J
O
S
U
V
W
X
Y
0
1
0
E TW13- **Protective Sleeve TW13
with flange connection.
Protection tube acc. DIN 43772 /2F 3F
welded version.
2
A
B
D
E
F
G
H
Y
1
2
3
4
8
9
A1
AD
E1
EA
EB
EC
FA
FB
FC
HA
HC
JE
JF
M
R
S
T
W
Y
2
B
C
S
T
U
W
X
Y
0
1
0
F TA50- Mounting Mount Sleeve Fitting TA50
Screw in.
HE
HF
HL
HM
HN
HQ
JC
JD
JE
JF
JK
JM
JN
JQ
JR
JS
JT
UL
UM
UN
UP
UR
US
B TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
A1
B1
B2
B4
D1
D2
D3
E1
GA
GD
GR
A
1
2
A
A2
B1
B3
C1
B TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
A1
B1
B2
B4
D1
D2
D3
E1
GA
GD
GR
A
1
2
A
A2
B1
B3
C1
B TID10- temperature transmitter display TID10
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84.
A1
B1
B2
B4
D1
D2
E1
GA
GR
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
TXU10- Instrument debugging package TXU10
for PC-programmable devices
The program sets the connection line for a PC with USB interface
AA
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
D TA30H- junction box TA30H
Retainer for terminal block or head
transmitter optional display.
Design: explosion proof
Cover: screwed, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50#150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
Protection Ex d/XP: IP66/67 (housing).
A1
B1
I1
1
2
A
B
C
D
E
F
G
Y
1
2
NA
B TMT180- **Module temperature transmitter TMT180
Temperature transmitter,PC-programable.
Application: RTD.
2-wire 4-20mA.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
1
2
1
2
2
3
4
XX
A
B TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
AA
B2
BA
GA
GD
GR
IA
NA
NN
A
1
2
A
B1
B3
C1
A1
A1
AA
A1
A2
LA
DIENST- Services
F
T
A
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
IA
1
TM131- industrial thermometer TM131
Modular thermometer with resistance
sensor or thermocouple.
Metrical version with exchangeable
insert for demanding applications in
chemical, oil/gas and power industry.
With thermowell or to be installed
into thermowell.
Measuring range: -200... 1.100oC/
-328...2.012oF
(depending on the configuration).
::Fastest response times for optimal
process control through iTHERM QuickSens
insert and fast response thermowell
options.
::Maximum robustness for highest process
safety through iTHERM StrongSens insert.
::Cost savings with recalibrations
through iTHERM QuickNeck coupling
::Material selection for a wide range
of applications.
AA
TS111- iTHERM TS111 core
Replaceable insert acc. IEC 60751.
Metric version acc. DIN 43735.
::Fastest response times for optimal
process control through iTHERM
QuickSens.
::Maximum robustness for highest process
safety through iTHERM StrongSens.
8A
AA
BA
BN
GA
GR
IA
NA
1
1B
C
1
1
2
212
222
AC1
AC2
X1
0A
1A