Семейство продуктов: Orbisphere 312xx Hydrogen Sensors
Orbisphere High Pressure Hydrogen (H₂) TC sensor with nitrogen purge, protection cap, ext. temp. sensor (170 bar)
HACH 31290HP
Allows you to monitor hydrogen in the power production process.

产品概述

Allows you to monitor hydrogen in the power production process.

High Pressure Hydrogen TC sensor with nitrogen purge and protection cap. With external temperature sensor adapter. Sensor cable to be ordered: 32505.03. Maximum pressure: 170 bar

This sensor is the successor model for 31260HP.

主要特点

  • Patented thermal conductivity (TC) sensor design:
  • Selective and precise measurement of hydrogen in gaseous or liquid samples:
  • No specific sample preparation required, the gas concentration is measured directly in the sample:
  • Rugged construction can handle harsh plant conditions and high sample pressures:
  • Flexibility of installation for better process control and very low maintenance:

技术参数

参数名称说明
Accuracy(Sample temp. 20 - 50°C within ± 5°C of calibration temperature) The greater of Membrane 29561A: ±1% of reading, or ±2 ppb, or ±0.03 cc/kg, or ±1.5 bar Membrane 2952A: ±1% of reading, or ±8 ppb, or ±0.1 cc/kg, or ±6 mbar Membrane 2935A: ±1% of reading, or ±25 ppb, or ±0.4 cc/kg, or ±20 mbar
Accuracy 2(Sample temp. 0 - 50°C independent of calibration temperature) The greater of Membrane 2952A: ±3% of reading, or ±60 ppb, or ±0.6 cc/kg, or ±20 mbar Membrane 2935A: ±3% of reading, or ±150 ppb, or ±2.5 cc/kg, or ±50 mbar
ApplicationPower
Certifications2004/108/EC - EN 61326-1
Cycle Time17 s
Flow RateTypical Flow Rate Membrane 29561A: 220 mL/min Membrane 2952A: 200 mL/min Membrane 2935A: 100 mL/min
ParameterHydrogen (H₂)
Protection ClassIP65
Purge connectionNitrogen Purge
Radiation Resistance LevelMembrane 29561A: 105 rad Membrane 2952A: 108 rad Membrane 2935A: 108 rad
RangeRange at 25 °C Membrane 29561A: 0 - 2 ppm, or 0 - 25 cc/kg, or 0 - 1.5 bar Membrane 2952A: 0 - 10 ppm, or 0 - 120 cc/kg, or 0 - 6 bar Membrane 2935A: 0 - 20 ppm, or 0 - 220 cc/kg, or 0 - 12 bar
Response Time17 s
Sample Pressure0 - 170 bar
Temperature Range-5 - 50 °C
Warranty6 months
Weight0.95 kg
What's included?Sensor only. Controller, sensor cable, flow-chamber or process connection must be ordered separately.

同系列其他配置

型号
31230.01Orbisphere Hydrogen (H₂) EC Sensor in stainless steel with EPDM O-rin
31292HPOrbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti
31292TCOrbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti
31290TCOrbisphere Hydrogen (H₂) TC Sensor with nitrogen purge, protection cap

资料下载

Моделей: 5 · свернуть