产品概述
Lower Maintenance, Less Downtime
The 5500sc Phosphate Analyzer needs only two liters of reagent to perform unattended for up to 90 days; twice as long as the Series 5000. The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps. Prognosys which is a predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime. No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently. Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the online silica analyzer to verify in a lab test.
主要特点
- 90 Days of Continuous Run Time:Two liters of reagent are required for the silica analyzer to perform unattended for up to 90 days; twice as long as the Series 5000.
- Save Time on Maintenance:The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps.
- Avoid Downtime:Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime.
- Clean, Fast and Easy Reagent Change:No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently.
- Verify Easily with Hach Lab Products so you don't Waste Time Second-guessing:Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | LR model: ±4 µg/L or ±4% of reading, whichever is greater; HR model: ±500 µg/L or ±5% of reading, whichever is greater |
| Alarm | Four relays output; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum Connection: 18 to 14 AWG wire, 18 AWG stranded recommended |
| Application | Pure water / Power |
| Certifications | CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 ) KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012) |
| Controller Compatibility | SC200, SC1000 |
| Enclosure Rating | IP56 / NEMA 4X |
| Fitting Type | Sample line and sample bypass drain: 6 mm (¼-in.) Air purge inlet: 6 mm (¼-in.) Chemical and case drains: 9.5 mm (3/8-in.) |
| Grab Sample | Grab Sample In and Grab Sample Out capability |
| Light Source | Class 1M LED (light emitting diode) with a peak wavelength of 810 nm |
| Lower Limit of Detection (LOD) | LR model: 4 µg/L HR model: 200 µg/L |
| Manual Languages | English French Spanish B. Portuguese Chinese Japanese Korean Thai German Italian C. Portuguese Czech Danish Dutch Polish Swedish Finnish Bulgarian Hungarian Romanian Lithuanian Russian Turkish Slovak Slovenian Croatian Greek Estonian |
| Measuring Principle | Colorimetric |
| Mounting | Wall, panel or table |
| Number of Channels | 2 |
| Operating Humidity | 5 - 95 % non-condensing (indoor use only) |
| Operating Temperature Range | 5 - 45 °C |
| Outputs | 4 - 20 mA |
| Parameter | High Range Phosphate |
| Pollution Degree | 2/II |
| Power Requirements (Voltage) | 24 VDC |
| Protection Class | I |
| Range | 200 - 50000 µg/L as PO₄ |
| Reagent Consumption | 2 L of each reagent every 90 days with 15 minute cycle time |
| Relays | Four; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum |
| Repeatability | LR model: ±1% HR model: ±500 µg/L or ±5% of reading, whichever is greater |
| Response Time | Typically, 9.5 minutes at 25 °C (77 °F); changes with temperature |
| Sample Flow Rate | 55 - 300 mL/min |
| Sample Pressure | 2 - 87 psi (to Preset Pressure Regulator) |
| Sample Temperature | 5 - 50°C (41 - 122°F) |
| Storage Conditions | -20 - 60 °C |
| Warranty | 12 months |
| Weight | 20 kg (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents |
| What's included? | List of content: 5500sc analyzer, reagents set for up to 90 days of use, installation kit, Hach user manuals |
应用领域
Boiler Water · Steam Cycle · Water Cycle
同系列其他配置
| 型号 | |
|---|---|
| 5500.KTO.PL.A2U | 5500sc Phosphate Low Range Analyzer, 2 Channels, Reagents Included |
| 5500.KTO.PL.A1U | 5500sc Phosphate Low Range Analyzer, 1 Channel, Reagents Included |
| 5500.KTO.PL.A4U | 5500sc Phosphate Low Range Analyzer, 4 Channels, Reagents Included |
| 5500.KTO.PH.A1U | 5500sc Phosphate High Range Analyzer, 1 Channel, Reagents Included |
| 5500.KTO.PH.A2U | 5500sc Phosphate High Range Analyzer, 2 Channels, Reagents Included |
| 5500.KTO.PH.A4U | 5500sc Phosphate High Range Analyzer, 4 Channels, Reagents Included |
| 5500.KTO.PH.D1U | 5500sc Phosphate High Range Analyzer, DC Powered, 1 Channel, Reagents |
| 5500.KTO.PL.D1U | 5500sc Phosphate Low Range Analyzer, DC Powered, 1 Channel, Reagents I |
| 5500.KTO.PL.D2U | 5500sc Phosphate Low Range Analyzer, DC Powered, 2 Channels, Reagents |
| 5500.KTO.PL.D4U | 5500sc Phosphate Low Range Analyzer, DC Powered, 4 Channels, Reagents |
| 5500.KTO.PH.D4U | 5500sc Phosphate High Range Analyzer, DC Powered, 4 Channels, Reagents |
资料下载
- Sensor Maintenance Made Easy With Predictive Diagnosys Reprint from Water Online, Dec 2012
- Understanding the Different Phosphorus Tests
- Introduction to Hach Services
- Service Data Sheet : 5500sc Silica and Phosphate
- 5500sc Phosphate CSI Engineering Specifications
- Maintenance and Troubleshooting : 5500sc Analyzer
- Unpacking Guide : 5500sc, Phosphate LR Analyzer
- Unpacking Guide : 5500sc Phosphate HR Analyzer
Похожие
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
CPVC Insertion Mounting Hardware 2", pHD Series
COVER-SERVICE REPLACEMENT
HACH