产品概述
Designed for water quality experts, the Hach HQ430D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart IntelliCALⓇ electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate. The IntelliCAL CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications.
主要特点
- Flexible Laboratory bench Conductivity/TDS Meter for efficient water quality parameters testing:Single input channel for flexible measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx), Temperature, Ion Selective Electrode (ISE) direct concentration reading for Ammonia, Ammonium, Fluoride, Chloride, Sodium - connect any IntelliCAL smart probe.
- Intuitive user interface for simple operation, reliable and accurate results:Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.
- Trust your measurements - IntelliCAL smart probes store all calibrations in the probe:Calibration history allows quick and easy change out of probes without re-calibrating. The HQD smart system records serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log for complete Good Laboratory Practice (GLP) traceability.
- Enhance data connectivity with easy to read results:Internal USB ports simplify data transfer, peripherals, and software updates and connection to PCs printer and keyboards, with a large ultra-bright backlit LCD screen with large font size for convenient reading.
- Complete convenient kit:Package content includes everything you need to start testing. Details below
技术参数
| 参数名称 | 说明 |
|---|---|
| Temperature correction | None; Linear; NaCl Non-Linear Natural Water. |
| Automatic Buffer Recognition | Yes |
| Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
| Calibration | Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); Standard sea water; User defined |
| Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
| Communication | Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC) |
| Compliance Certifications | CE.WEEE |
| Conductivity measurement | Yes |
| Conductivity Measurement Range | 0.01 µS/cm - 200.0 mS/cm |
| Conductivity resolution | 0.01 µS/cm - 0.1 mS/cm upon selected measuring range |
| Contents | Meter + Probe(s) + Lab. Accessories + Reagents |
| Custom Calibration Standards | Yes |
| Data Export | Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken. |
| Data Memory | 500 records/FIFO |
| Data Storage | Automatic, GLP ISO compliant reading data stored with calibration details. |
| Dimensions | (H x W x D) 86 x 175 x 235 mm (3.38 x 6.88 x 9.25 in.) |
| Display | Detailed mode/Large mode |
| Display Type | 440 x 160 pixel LCD with backlight illumination |
| DO Measurement Range | 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation |
| DO Resolution | 0.1 |
| DO sensor calibration | • 100% (water-saturated air (100%) calibration • 100% with 0 (water-saturated air (100%) calibration with 0 point • mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution) • mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point) • Factory (calibration with the default LDO calibration) |
| Electrode stand | Included |
| GLP Features | Date; Time; Sample ID; Operator ID |
| Instrument | Benchtop |
| IP Rating | IP54 (Resistant to spray of water; Dust-proof) |
| ISE Direct Measurement Range | Yes |
| ISE Electrode Calibration | 2 - 5 points |
| Kit? | Yes |
| Languages | English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian |
| Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
| Measurement Method | Probe specific programmed method settings |
| Model | HQ430D – Multi/1 Channel |
| mV Measurement at Stable Reading | Yes |
| mV Measurement Range | -1500 - 1500 |
| mV Resolution | 0.1 mV |
| Needed Cable Length | 1 |
| Operating Error Messages | Clear text error messages displayed |
| Operating Humidity | 90 % relative humidity (non-condensing) |
| Operating Interface | Soft Touch Keypad |
| Operating Temperature | 0 - +60 °C (32 - 140 °F) |
| ORP Electrode Calibration | Predefined ORP standards (including Zobell's solution) |
| Parameter | pH/Oxydo Reduction Potential (ORP) Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity Dissolved Oxygen (DO) Biochemical Oxygen Demand (BOD) Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium |
| PC Data Transfer Software | HQD Series Meter Data Transfer Utility |
| pH Buffer Sets | Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH DIN: 1.09, 4.65, 9.23 pH User-defined custom buffer sets |
| pH Electrode calibration | 1 - 3 Calibration points Calibration summary data logged and displayed |
| pH Measurement Range | 0 - 14 pH |
| pH Resolution | Selectable: 0.001/0.01/0.1 pH |
| Printer | Yes, Optional |
| Probes included | CDC40101 |
| Resistivity Measurement | 2.5 Ω.cm - 49 MΩ.cm |
| Resistivity Resolution | 0.1 |
| Salinity Measurement Range | 0 - 42 (ppt) (‰) |
| Salinity Resolution | 0.01 (ppt) (‰) |
| Sensor | CDC40101 |
| Sensors | Sensor A: CDC40101 Sensor B: NA Sensor C: NA |
| TDS Measurement Range | 0.00 mg/L - 50.0 g/L as NaCl |
| TDS Resolution | 0.01 mg/L - 0.1 g/L upon measuring range. |
| Temperature Compensation | Automatic Temperature compensation for pH |
| Temperature Measurement | °C or °F |
| Temperature Range | -10°C - 110 °C |
| Temperature Resolution | 0.1 |
| Type of measurement | Lab Water Quality applications. |
| Warranty | 36 months |
| Weight | 750 g (1.65 lb) without batterie; 850 g (1.87 lb) with batteries |
| What's included? | Meter package includes HQ430D Laboratory Multi Meter, Universal electrode Stand with electrode holder, CDC401 conductivity/TDS/salinity cell with 1 m cable, NaCl conductivity standard (1000 µS/cm, 491 mg/L, 100 mL), 4 Alkaline 1,5V AA batteries, Power Supply Adapter, Power Cord, USB cable for data transfer, and Operating Documentation. |
应用领域
Municipal Water · Production Water · QA/QC Lab · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| 8507800 | HQD HQ440D Laboratory Ammonium (NH₄⁺) Ion Meter Package with ISENH4181 |
| 8507900 | HQD HQ440D Laboratory Chloride (Cl⁻) Ion Meter Package with ISECL181 I |
| 8508000 | HQD HQ440D Laboratory Fluoride (F⁻) Ion Meter Package with ISEF121 Ion |
| 8508100 | HQD HQ440D Laboratory Nitrate (NO₃⁻) Ion Meter Package with ISENO3181 |
| 8508200 | HQD HQ440D Water Quality Laboratory pH and ISE Fluoride (F⁻) Ion Meter |
| 8508400 | HQD HQ440D Water Quality Laboratory ISE Ammonia (NH₃) and Nitrate (NO₃ |
| 8508700 | HQD HQ440D Water Quality Laboratory pH, Conductivity and Dissolved Oxy |
| 8510200 | HQD HQ440D Water Quality Laboratory pH and Conductivity Meter Package |
| 8510100 | HQD HQ440D Water Quality Laboratory Biochemical Oxygen Demand (BOD) an |
| 8507570 | HQD HQ440D General Purposes Water Laboratory pH and Conductivity/TDS M |
| 8507000 | HQD HQ440D Laboratory Sodium (Na⁺) Ion Meter Package with ISENA381 Ion |
| 8507600 | HQD HQ440D Laboratory Ammonia (NH₃) Ion Meter Package with ISENH3181 I |
| 8509500 | HQD HQ411D Laboratory Starter pH Meter Package with PHC101 Low Mainten |
| 8508600 | HQD HQ440D Water Quality Laboratory pH Meter Package with PHC281 pH El |
| 8508500 | HQD HQ440D Water Quality Laboratory Biochemical Oxygen Demand (BOD) Me |
| 8505350 | HQD HQ440D General Purpose Water Laboratory pH Meter Package with Stan |
| 8507560 | HQD HQ411D Laboratory Starter pH Meter Package with PHC201 General Pur |
| 8505450 | HQD HQ440D Laboratory pH Meter Package for Dirty Samples with Fast Res |
| 8505850 | HQD HQ440D Water Laboratory Meter Package for Low Ionic Strength Sampl |
| 8506050 | HQD HQ440D High Performance Water Laboratory pH Meter Package for Exte |
| 8506250 | HQD HQ440D Laboratory pH Meter Package for Semi-Solid Samples with Sta |
| 8506450 | HQD HQ440D Laboratory pH Meter Package for High Alkalinity Samples wit |
| 8507450 | HQD HQ440D Laboratory pH Meter Package for Flat Surface Measurements w |
| 8508300 | HQ440D Water Quality Lab pH & ISE NH₃ Ion Meter Package, PHC281 pH Ele |
25 更多配置.
资料下载
- Technical Note pH Trace Analysis
- Technical note pH measurement system
- Calibration of the High Purity 8362sc pH Electrode
- Calibración del electrodo de pH de alta pureza 8362sc
- Measuring Scale Forming Potential in Cooling Water
- Electrochemistry Theory and Practice
- Introduction to Hach Services
- A melhor solução para resultados precisos em todas as aplicações
Похожие
HACHConductivity Standard Solutions, 1000 µS/cm (491 mg/L NaCl)
HACHPolymetron Conductivity Module for SC200 Ultra Pure Controller
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
HACHCDW97-K10, Conductivity probe for salinity and brackish water
Solution, Conductivity Assembly
HACHRadiometer Conductivity Cells
HACH