Семейство продуктов:
Контактный датчик электропроводности
Sanitary Flange-Style Conductivity Sensor, Cell Constant 10.0, 2 inch CIP Flange, Digital Gateway, 1m Extension CableСнято с производства
Nominal Cell Constant (K) = 10.0, Sanitary (CIP) 2 inch Flange, 6m (20 ft) Analog Cable, 316 Stainless Steel Electrode, Includes Digital Gateway and 1m (3.3 ft) Digital Extension Cable
产品概述
Nominal Cell Constant (K) = 10.0, Sanitary (CIP) 2 inch Flange, 6m (20 ft) Analog Cable, 316 Stainless Steel Electrode, Includes Digital Gateway and 1m (3.3 ft) Digital Extension Cable
主要特点
- High Performance Design:These enhanced performance sensors are manufactured to exacting tolerances using high quality, rugged materials for demanding applications including ultra-pure water, clean-in-place (CIP), and boiler/condensate monitoring. Each sensor is tested to determine its unique, absolute four-digit cell constant. Also, each sensor has a Pt 1000 RTD temperature element built into its tip for exceptionally fast response to changes in temperature with ±0.1ºC accuracy.
- Resistivity and Conductivity Measurement Capability:These enhanced performance sensors measure from theoretically pure water (0.057 µS/cm or 18.2 MΩ) up to 200,000 µS/cm. Hach’s sc Digital Controllers accept multiple digital sensor inputs, and can be user-set to measure conductivity, resistivity,TDS, salinity, or one of six calculated measurements.
- Versatile Mounting Styles:Sanitary clean in place (CIP) style sensors have 316 stainless steel electrodes and an integral 1-1/2-inch or 2-inch flange. These sensors can be installed using standard sanitary mounting hardware.
- Full-Featured "Plug and Play" Hach sc Digital Controllers:There are no complicated wiring or set up procedures with any Hach sc controller. Just plug in any combination of Hach digital sensors and it's ready to use—it’s “plug and play.”
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ± 2 % of reading above 200 µS/cm |
| Cable Length | 7 m (23 ft.) |
| Cell Constant k | 10 cm-1 |
| Digital Gateway | External Digital Gateway |
| Electrode Material | 316 Stainless Steel |
| Flow | 0 - 3 m/s |
| Installation Kit | 2" Flange |
| Installation Requirement | 316 Stainless Steel |
| Installation style | Sanitary flange |
| Operating Temperature Range | -20 - 200 °C |
| Pressure Range | 0 - 300 psi (20.7 BAR) |
| Range | 0 - 200000 µS/cm |
| Repeatability | ± 0.5 % of reading |
| Response Time T90 | 30 s of step change |
| Sensitivity | ± 0.5 % of reading |
| Sensor Thread | 0.75" |
| Sensor Type | Digital |
| Transmission Distance | 100 m |
| Transmission Distance | 1000 m |
| Warranty | 12 months |
| What's included? | Includes: sensor with cable, digital gateway, extension cable and manual |
应用领域
Membrane Protection · Nutrient Monitoring · Nutrient Monitoring · Secondary Treatment · Secondary Treatment · Ultrapure Water
同系列其他配置
| 型号 | |
|---|---|
| D3422B3 | Contacting Conductivity Digital Sensor, 0.50 Cell Constant, Compressio |
| D3422D3 | Digital Contacting Conductivity Sensor, Compression Fitting Style, Cel |
| D3422E3 | Contacting Conductivity Digital Sensor, Compression Style, 10 Cell Con |
| D3433B8 | PPS Body General Purpose Digital Contacting Conductivity Sensor for lo |
| D3444B8 | Stainless Steel Digital Contacting Conductivity Sensor for Low Conduct |
| D3444D8 | Digital Stainless Steel Digital Contacting Conductivity Sensor for Hig |
| D3422A2 | Digital Contacting Conductivity Sensor for low conductivity (k=0.05) w |
| D3422C3 | Digital Contacting Conductivity Sensor, Compression Fitting Style, Cel |
| D3455A6 | Digital Sanitary (CIP) Contacting Conductivity Sensor for Low Conducti |
| D3455C7 | Digital Sanitary Flange Style Sensor, Stainless Steel Electrode, 1.0 C |
| D3422A1 | Contacting Conductivity Digital Sensor, 0.05 Cell Constant, Compressio |
| D3433E8 | Digital Contacting Conductivity Sensor, General Purpose, PPS Body, Cel |
资料下载
- Introduction to Hach Services
- Complete Water Analysis Solutions for the Food Industry
- Soluciones completas de análisis de agua INDUSTRIA ALIMENTARIA
- Contacting Conductivity/Resistivity Sensors
- User Instructions: sc Sensors Class 1, Division 2 Safety Precautions
- Digital Contacting Conductivity Sensor User Manual
- Basic User Manual : Contacting Conductivity Analog Sensor
Похожие
A
HACHSolution, Conductivity Assembly
Далее →
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
Далее →
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
Далее →
HACHRadiometer Conductivity Cells
Далее →
HACHConductivity Solution, 1000-2000 µS/cm, 1 L
Далее →
HACHConductivity Solution, 2000-150,000 µS/cm, 1 L
Далее →
HACHConductivity Solution, 200,000-300,000 µS/cm, 1 L
Далее →
HACHConductivity Solution, 300,000-800,000 µS/cm, 1 L
Далее →