Fluoride measurement in wastewater and industrial process water can be distorted by matrix effects from ions such as calcium and aluminum. The EZ3508sc uses a standard addition method to compensate for these interferences, delivering accurate, repeatable fluoride results while minimizing reagent consumption.
Designed for reliable operation, gel-filled ISE electrodes eliminate electrolyte refilling and automated cleaning and calibration reduce hands-on maintenance. Digital communication protocols integrate the analyzer into your network for immediate access to results, diagnostics and status.
Benefits: - Standard addition compensates for matrix effects in complex samples - Accurate, repeatable fluoride results with low reagent consumption - Gel-filled ISE electrodes eliminate electrolyte refilling - Automated cleaning and calibration reduce manual service - Digital connectivity for fast access to results, diagnostics and status
主要特点
- Consistent Results in Challenging Conditions:Fluctuating water quality often compromises conventional monitoring, leading to unstable readings. The EZ3508sc uses discontinuous and standard addition modes to compensate for these matrix interferences. You get accurate, continuous fluoride data for stable process control, even as conditions change.
- Reduced Maintenance and Manual Effort:Gel-filled ion selective electrodes eliminate electrolyte refilling, while automated cleaning and calibration reduce routine service needs. Discontinuous standard addition method optimizes buffer and reagent consumption; lowering site visits, operating costs, and overall maintenance effort.
- Seamless Integration and Connectivity:Isolated data makes process control and reporting difficult. The integrated controller platform supports standard digital communication protocols for easy connection to your existing network. You gain immediate access to critical insights, supporting faster decision-making and remote troubleshooting.
- Streamlined Operation and Usability:Complex instrumentation often leads to training bottlenecks and operational errors. The unified controller interface simplifies setup and daily interaction. Operators of any experience level can easily manage the system, reducing training requirements and preventing errors during routine checks.
技术参数
| 参数名称 | 说明 |
|---|---|
| Ambient Temperature | 50 - 86 °F (10 - 30 °C) ± 4 °C deviation at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard 4, optional: 8 |
| Automatic cleaning | Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Calibration | Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced |
| Certifications | CE, ETL certified to UL and CSA safety standards, UKCA |
| Cycle Time | No dilution Default: 5 minutes Continuous: 5 minutes Internal dilution Default: 10 minutes Continuous: 8 minutes |
| Demineralized Water | Internal dilution option: Rinse water and Dilution water |
| Digital Outputs | Relays: 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150) Ethernet Connections: Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP RS485 communication: Profibus DP or Modbus RTU |
| Dimensions (H x W x D) | 688 mm x 460 mm x 340 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Earth connection Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar |
| Interferences | Metal ions like aluminium [(Al)³+] > 72 mg/L, calcium [(Ca)²+] > 108 mg/L and iron [(Fe)²+/(Fe)³+] > 150 mg/L. Fats, oil, proteins, surfactants and tar. |
| Lower Limit of Detection (LOD) | No dilution 0.2 - 10 mg/L F-: 0.2 mg/L 0.5 - 25 mg/L F-: 0.5 mg/L 1 - 50 mg/L F-: 1 mg/L 2 - 100 mg/L F-: 2 mg/L Internal dilution 10 - 500 mg/L F-: 10 mg/L 20 - 1000 mg/L F-: 20 mg/L |
| Material | Hinged part: Thermoform ABS, Door: PMMA Wall section: Galvanized steel, powder coated |
| Measurement method | Discontinuous measurement by combined Ion-Selective Electrode with standard addition |
| Measurement Method | Ion-Selective Electrode (standard addition) |
| Number of sample streams | Standard: 1 Optional accessory for 2, 4, or 8 sample streams |
| Parameter | Fluoride |
| Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
| Precision | Better than 2% full scale range for standard test solutions |
| Protection Class | IP44 |
| Range | No dilution 0.2 - 10 mg/L F- 0.5 - 25 mg/L F- 1 - 50 mg/L F- 2 - 100 mg/L F- Internal dilution 10 - 500 mg/L F- 20 - 1000 mg/L F- |
| Reagent Requirements | Keep between 50 - 86 °F (10 - 30 °C) |
| Sample Flow Rate | 100 - 300 mL/min |
| Sample Pressure | By external overflow vessel (open to atmospheric pressure) |
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Sample Temperature | 50 - 86 °F (10 - 30 °C) |
| Validation | Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Warranty | 12 months |
| Weight | Max. 77 lb (35 kg) |
| What's included? | EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Analyzer, 1 stream, 4x mA, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode, 1 x empty 5L Reagent Container with Fittings (for F Standard Solution) and 1 x empty 10L Reagent Container with Fittings (for Buffer Solution) |
应用领域
Municipal Water
同系列其他配置
| 型号 | |
|---|---|
| EZ1012.9700140T | EZ1012sc Cyanide Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1035.9700140T | EZ1035sc Silica Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1036.9700140T | EZ1036sc Sulfate Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1037.9700140T | EZ1037sc Sulfide Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ3005.9700140T | EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyzer, 1 stream, 4x |
| EZ3008.9700140T | EZ3008sc Fluoride Ion-Selective Electrode (ISE) Analyzer, 1 stream, 4x |
| EZ3505.9700140T | EZ3505sc Chloride Ion-Selective Electrode (ISE) Standard Addition Anal |
| EZ1016.9700140T | EZ1016sc Hardness, total Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1017.9700140T | EZ1017sc Hardness, calcium Colorimetric Analyzer, 1 stream, 4x mA Outp |
资料下载
- Brochure EZ Series Online Analysers
- EZ Series Online Analyzers
- Analizadores en continuo de la serie EZ
- Analisadores on-line da série EZ
- Analyseurs en ligne série EZ
- EZ 시리즈 온라인 분석기 완벽한 솔루션 제공
- EZ Series: Accurate Fluoride Monitoring for Regulatory Confidence
- EZ3000sc/EZ3500sc Series Analyzers Service Data Sheet
Похожие
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
Accu4 Spare Chamber with Plumbing, High Pressure
HACH