产品概述
IntelliCALⓇ ISENH3181 is a digital, combination gas-sensing, ammonia ion selective electrode (ISE) with a with a replaceable membrane module, refillable outer body, a non-refillable gel 3M KCl reference with a double junction porous PTFE annular ring and built-in temperature sensor. The electrode measures ammonia concentration in water samples. A 50 mL bottle of 0,1 M NH4Cl Electrode Filling Solution is included with the probe.The laboratory version of this ISE is shockproff with its Epoxy plastic body.The IntelliCAL ISENH3181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISENH3181 is ideal for measuring ammonia concentrations in wastewater, drinking water and general water quality applications.
主要特点
- Provides fast, stable, and accurate results:Refillable outer body, an easy to maintain modular membrane design, and a large annular reference junction for maximum surface area between sample and reference electrolyte provide great measurement stability. IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number.
- Ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
- User alerted when re-calibration is needed:No guesswork needed to provide most reliable and accurate results with each measurement.
- Can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±0.02 mV or 0.05%, whichever is greater |
| Cable Length | 3 m (9.84 ft) |
| Electrode Type | Non-Refillable Gel Reference Element, Replaceable membrane |
| Filling Solution | 0.1 M NH4Cl (#4447226) |
| ISA Required | Ammonia ISA (#4447169) |
| Junction | Double Annular Junction |
| Kit? | No |
| Length | 175 mm (6.89 in.) |
| Method Type | Field: Non-Refillable Gel Reference Element, Replaceable membrane |
| Parameter | Ammonia |
| Probe Type | Standard |
| Product Kit | Model: ISENH381 Accessories Included: None |
| Range | 0.01 mg/L (5 x 10-7 M) - 14 g/L (1 M) NH3-N |
| Reference Type | Ag/AgCl |
| Resolution | Selectable up to 4 significant digits |
| Sample depth | 25.4 mm (1 in.) |
| Sample Volume | 15 mL |
| Sensor material | Epoxy |
| Sensor Type | pH Glass with replaceable NH₃ sensitive membrane |
| Special Features | Easy-to-replace membrane modules. |
| Temperature Accuracy | ±0.3 °C (±0.54 °F) |
| Temperature Range | 5 - 50 °C (41 - 122 °F) |
| Temperature Resolution | 0.1 °C (0.18 °F) |
| Test requirements | Parameter Needed: Ammonia Minimum Sample Depth (mm): 26 |
| Thermistor | ATC |
| Warranty | 6 months |
| Weight | 0.15 kg |
| What's included? | IntelliCAL ISENH3181 combination Ammonia ISE, 3 m cable (ISENH318101), 3-pack of replacement IntelliCAL ammonia membrane modules (no. 5812711), a 50 mL bottle of electrode fill solution (no. 4447226), Test certificate, and Basic User Manual. |
应用领域
Municipal Water · Potable Water · Production Water · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| ISENH418101 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 1 |
| ISENH418103 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 3 |
| ISENO318101 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 1 m |
| ISENO318103 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 3 m |
| ISENH4181AP | IntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) w |
| ISENO3181AP | IntelliCAL ISENO318101 Nitrate (NO₃⁻) Ion Selective Electrode (ISE) wi |
| ISENA38103 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 3 m ca |
| ISENA38101 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 1 m ca |
| ISENH318101 | IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m |
| ISECL18101 | IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 1 m |
| ISECL18103 | IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m |
| ISEF12103 | IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 3 m ca |
| ISEF12101 | IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 1 m ca |
| ISENH3181AP | IntelliCAL ISENH318101 Ammonia (NH₃) Ion Selective Electrode (ISE) wit |
| ISECL181AP | IntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) wit |
| ISEF121AP | IntelliCAL ISEF12101 Fluoride (F⁻) Ion Selective Electrode (ISE) with |
| ISENA381AP | IntelliCAL ISENA38101 Sodium (Na⁺) Ion Selective Electrode (ISE) with |
资料下载
- Brine Analysis Package
- Introduction to Ion-Selective Measurement
- Electrochemistry Theory and Practice
- Introduction to Hach Services
- A melhor solução para resultados precisos em todas as aplicações
- Una sólución prfec para obtener resultados precisos en todas las aplicaciones
- โซลูชันที่ มอบผลลัพธ์ที่ แม่นยำสูงสุด สำหรับทุกการใช้งาน
- Care Advantage Flyer : Complete service solution for all your instruments
Похожие
HACHТермореактор (быстрый реактор COD)
HACHМногоканальный электрохимический анализатор
HACHКарманный анализатор воды Pro/Pro+
HACHСерия тест-полосок для анализа качества воды
HACHИзмеритель цветности жидкости
HACHПортативный анализатор токсичности воды
HACHСпециальный Сервис / Прочие TSS
HACH