产品概述
The first maintenance-free optical oxygen sensor for power plants.
High accuracy Luminescent Dissolved Oxygen (LDO) Sensor optimised for power industry application. The absence of membrane and electrolyte means that the sensor accuracy is unaffected by process changes such as changes in flow. Maintenance and operating costs are significantly reduced. The sensor has been designed to ensure mechanical robustness to extend operational lifetime and optimise its total cost of ownership.
The quick response time comes from the Orbisphere K1100 two second measurement frequency. Capable of measuring accurately at this frequency over a 12 month period. With no calibration required, the K1100 surpasses other optical and electrochemical sensors that display significant drift after only a few months in the same conditions. This optical sensor is designed for minimal drift, resulting in it being the most stable sensor with the longest calibration intervals achievable in the market. This is possible by its long-life spot and optimised controller software.
Maintenance intervention is limited to 2 minutes and a zero point calibration, offering significant cost benefits compared with traditional electrochemical sensors and other luminescent sensors. Using gas phase calibration means chemicals are not required, and therefore the task is easier and safer without reducing measurement precision.
主要特点
- One calibration per year:One zero point calibration per year is all that is needed with the K1100 sensor. Designed for minimal drift, luminescent technology makes the K1100 sensor the most stable sensor with the longest calibration interval in the industry.
- No membranes = two minutes of maintenance:With no membranes to replace and no electrolyte solution to replenish, the K1100 requires only two minutes of maintenance per year. Corrosive or hazardous chemicals are not required, making the annual task faster, easier and safer without reducing measurement precision.
- Low cost retrofit:The complete system consists of a Controller, a flow chamber, and the K1100 Luminescent Dissolved Oxygen Sensor. The sensor is compatible with Hach Orbisphere 28 mm flow chambers, eliminating the need for engineering changes. Installation is fast and easy and does not require special preparation.
- A new level of confidence:The K1100 optical sensor is the first to use luminescent measurement technology to measure both ppb and ppm oxygen levels in power plants. Since 1978, Hach Orbisphere sensors have set the industry standard for oxygen measurement by delivering confidence to every water chemistry manager. The K1100 maintains this tradition and offers significant operating and cost benefits.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ± 0.02 ppm or 3 % whichever is greater |
| Ambient Temperature | -5 - 50 °C (23 - 122°F) |
| Analog Outputs | 3 Smart 0/4 to 20 mA (500 Ohms) programmable as linear or tri-linear, configurable to send diagnostics or alarm informations. |
| Application | In-line |
| Calibration | Two points at cap replacement (zero and air), one during use (air) |
| Certifications | 2004/108/EC - EN 61326-1 |
| Communication Capabilities | 3 x 0/4-20 mA; RS485; Ethernet |
| Display Resolution | 0.1 ppb |
| Lower Limit of Detection (LOD) | 0.015 ppm |
| Mounting | 28 mm Orbisphere fitting |
| Parameter | Oxygen |
| Power Requirements (Voltage) | 100 - 230 VAC |
| Range | 0 - 40 ppm dissolved O2 (DO) |
| Relays | Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC). |
| Repeatability | ± 0.015 ppm or 2 % whichever is greater |
| Reproducibility | ± 0.02 ppm or 3 % whichever is greater |
| Response Time | (90%) <10 s (gas phase); <50 s (liquid phase) |
| Sample Flow Rate | 50 - 300 mL/min |
| Sample Pressure | 1 - 20 bar absolute (14.5 - 290 psi) |
| Sample Temperature | -5 - 50°C (23 - 122°F) |
| Sensors | K1100 LDO |
| Storage Conditions | -5 °C - 100 °C |
| Temperature Range | Accurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F) |
| Warranty | 12 months |
| Weight Sensor | 0.6 |
| What's included? | K1100 Sensor only Controller, sensor cable, flow-chamber or process connection must be ordered separately |
应用领域
Boiler Water · Steam Cycle · Ultrapure Water
资料下载
- Optical Dissolved Oxygen Measurement in Power and Boiler Applications
- Practice report: Dissolved Oxygen Measurement in Power Plants
- Mesure de l’oxygène dissous dans les centrales électriques
- Medición de oxígeno disuelto en centrales de energía
- Connah's Quay Opts for Almost Zero Maintenance DO Monitors
- Connah’s Quay opta por monitores de OD que casi no necesitan mantenimiento
- Application Note: Increasing LDO Longevity in Brewing
- Practice report: Dissolved Oxygen Measurement in Power Plants
Похожие
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
Replacement Protector for Clark DO sensor
HACHField Service Partnership, 3100 LDO, 1 Service/Year
HACHBench Service Partnership, 3100 LDO, 1 Service/Year
HACHPocket Dissolved Oxygen (DO) Meter
HACHField Service Partnership, 2586sc Oxygen Scavenger Analyzer, 2 Services/Year
HACHOrbisphere 510 Controller O₂ (EC), CO₂ (TC), Wall Mount, 100-240 VAC, 0/4-20mA, Ext. Press.
HACH