产品概述
Rugged and portable, the HQ4100 delivers precise Conductivity measurements with a single probe input and reliable performance in any environment.
The HQ4100 Portable pH Meter and Multi-Parameter Water Quality Meter is expertly crafted to handle complex water analysis needs, making it a reliable solution for both laboratory and field environments.
Equipped with a single probe input, the HQ4100 allows professionals to measure a wide variety of parameters with precision and ease. Whether you're testing pH, conductivity, dissolved oxygen, ORP, salinity, TDS (Total Dissolved Solids), or using ion-selective electrodes (ISEs), the HQ4100 consistently delivers accurate, dependable results for every application. Its large, full-color display enhances usability by providing clear, detailed readings, enabling efficient and informed decision-making.
The HQ4100’s rugged, IP67-rated construction ensures durability and peak performance even in tough environments. Its intuitive interface includes easy-to-follow, on-screen step-by-step instructions for operations, calibration, and troubleshooting, minimizing training needs while maintaining precision at every step. Built to adapt to the unique demands of professionals, it combines durability, ease of use, and accuracy into one reliable instrument.
Need greater flexibility or the ability to measure even more parameters simultaneously? Consider upgrading to the HQ4200 (Part Number: LEV015.53.4200A), which features two probe inputs, allowing you to monitor more parameters without switching probes. Or take it a step further with the HQ4300 (Part Number: LEV015.53.4300A), offering three probe inputs for simultaneous measurements and ultimate efficiency. Both advanced models maintain the trusted accuracy and durability of the HQ Series, with the flexibility to streamline your most demanding workflows.
The HQ Series is a versatile family of water quality meters designed to meet a wide range of needs. Each model offers the same renowned reliability and performance, tailored with unique features to fit specific applications. From the HQ4100's streamlined single-probe design to the HQ4200's enhanced dual-probe input, and the HQ4300's advanced three-probe system, you can find the perfect tool to match your workflow, whether in the lab or the field.
主要特点
- Performing a successful calibration has never been so simple:Most measuring issues are due to incorrect calibration procedures. With our illustrated, step-by-step on-screen calibration and troubleshooting procedures, water quality professionals can succeed every time.
- Deliver your daily activity in just a few clicks:Whether you are at your facility or working in the field, the Hach® HQ Series portable meter ensures your data will be safely transferred via USB.
- Sensors designed for every application:We offer standard laboratory and rugged field IntelliCALⓇ smart sensors available with the HQ Series to measure a wide variety of parameters including Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature, Conductivity, and pH. IntelliCAL smart probes are automatically recognized by HQ meters, retain calibration history and method settings to minimize errors and setup time. They incorporate proven technology to deliver superior accuracy and response times – even when measuring challenging samples or challenging operating environments.
- Peace of mind: Hach service and support will be there for you:Our Technical Support, Field Service, and Central Service Teams work together with over 80 years of electrochemistry expertise to help you maximize instrument uptime, ensure data integrity, maintain operational stability, and reduce compliance risk. Never feel alone when you need support.
技术参数
| 参数名称 | 说明 |
|---|---|
| Temperature correction | None; Linear; NaCl Non-Linear Natural Water. |
| Accessories Included | USB charger, power cable, and clips |
| Automatic Buffer Recognition | Yes |
| Backlight | Yes |
| Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
| Calibration | Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); Standard sea water; User defined |
| Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
| Certifications | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
| Conductivity Measurement Range | Yes |
| Custom Calibration Standards | Yes |
| Data Export | USB connection to PC or USB storage device (limited to the storage device capacity). |
| Data Memory | 100,000 data points |
| Data Storage | Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. |
| Dimensions (H x W x D) | 63 mm x 97 mm x 220 mm |
| Display | Up to 3 parameters at a time, dependent on HQ model |
| Display Type | 640x480 Color TFT |
| DO Measurement Range | 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation |
| DO Resolution | 0.1 |
| Enclosure Rating | IP67 (with battery compartment installed) |
| GLP Features | Date; Time; Sample ID; Operator ID, Calibration |
| Inputs | 1 |
| Instrument | Portable |
| ISE Direct Measurement Range | Yes |
| ISE Electrode Calibration | Yes |
| Kit? | Meter only |
| Languages | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
| Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
| Measurement Method | Probe specific programmed method settings |
| Model | HQ4100 Multi/ISE/1 Channel |
| mV Measurement at Stable Reading | Yes |
| mV Measurement Range | Yes |
| mV Resolution | 0.1 mV |
| Operating Error Messages | Clear text error messages displayed |
| Operating Humidity | 90% (non-condensing) |
| Operating Interface | Soft Touch Keypad |
| Operating Temperature | 14 - 140 °F (-10 - 60 °C) |
| ORP Electrode Calibration | Predefined ORP standards (including Zobell's solution) |
| Parameter | pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP, ISE |
| pH Buffer Sets | Colour-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 DIN: 1.09, 4.65, 9.23 User-defined custom buffer sets |
| pH Electrode calibration | 1 - 3 Calibration points Calibration summary data logged and displayed |
| pH Measurement Range | 0 - 14 pH |
| pH Resolution | Selectable: 0.001/0.01/0.1 pH |
| Power Supply | Rechargeable lithium-ion battery 18650 (internal) Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external) |
| Probe Type | Intellical Standard Laboratory or Rugged Field |
| Protection Class | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
| Range | 14 - 212 °F (-10 - 100 °C) |
| Salinity Measurement Range | 0 - 42 (ppt) (‰) |
| Salinity Resolution | 0.01 (ppt) (‰) |
| Storage Conditions | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
| TDS Measurement Range | 0.00 mg/L - 50.0 g/L NaCl |
| TDS Resolution | 0.01 mg/L - 0.1 g/L upon measuring range |
| Temperature Compensation | Automatic Temperature compensation for pH |
| Temperature Measurement | °C or °F |
| Temperature Resolution | 0.1 °C |
| Type of measurement | Field Measurements |
| Warranty | 36 months |
| Weight | 530 g (Meter only) |
| What's included? | HQ4100 Portable pH/ORP/EC/TDS/DO/ISE Multi-Meter, 1 channel, includes manuals, Li-Ion batteries, USB charger with cable for USA. |
应用领域
Groundwater · Influent for Wastewater · Municipal Water · Primary Treatment · Secondary Treatment · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| LEV015.53.1110A | HQ1110 Portable pH/ORP/mV Meter, w/o electrode |
| LEV015.53.1130A | HQ1130 Portable Dissolved Oxygen Meter, w/o electrode. |
| LEV015.53.1140A | HQ1140 Portable Conductivity/TDS Meter, w/o electrode |
| LEV015.53.2100A | HQ2100 Portable Multi-Meter pH, Conductivity, TDS, Salinity, Dissolved |
| LEV015.53.2200A | HQ2200 Portable Multi-Meter pH, Conductivity, TDS, Salinity, Dissolved |
| LEV015.53.4200A | HQ4200 Portable Multi-Meter, pH, Conductivity, TDS, Salinity, Dissolve |
| LEV015.53.4300A | HQ4300 Portable Multi-Meter, pH, Conductivity, TDS, Salinity, Dissolve |
资料下载
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- HQ Series Portable Meters
- Medidores portátiles de la serie HQ
- Appareils de mesures portatifs HQ Series
- Medidores portáteis da série HQ
- มิเตอร์วัดคุณภาพน้ำแบบ พกพา HQ Series
Похожие
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
HACHConductivity Solution, 1000-2000 µS/cm, 1 L
HACHConductivity Solution, 2000-150,000 µS/cm, 1 L
HACHConductivity Solution, 200,000-300,000 µS/cm, 1 L
HACHConductivity Solution, 300,000-800,000 µS/cm, 1 L
HACH