LPV444.99.00310

LPV444.99.00310
Семейство продуктов: Лабораторный измеритель мутности
TL2350 Tungsten Lamp Turbidimeter, EPA, 0 - 10000 NTU
HACH LPV444.99.00310
Trust the TL2350 Turbidimeter for dependable, precise measurements and accurate turbidity testing

产品概述

Trust the TL2350 Turbidimeter for dependable, precise measurements and accurate turbidity testing

The TL2350 Tungsten Lamp Laboratory Turbidimeter delivers precise, reliable turbidity measurements for a broad range of sample types and meets the requirements of EPA Method 180.1. Engineered for accuracy and simplicity, this benchtop turbidimeter streamlines water quality testing in fast-paced laboratory settings. Its robust tungsten lamp light source provides dependable readings across a wide measurement range of 0–10.000 NTU.

• Reduce errors and eliminate uncertainty with automatic sample stability detection that ensures every data point is accurate and reliable. • Minimize mistakes and ensure quality results with the intuitive color touchscreen and guided, step-by-step instructions—helping every user follow best practices and achieve consistent, dependable measurements. • Boost efficiency and reduce downtime with rapid USB data export and integrated self-diagnostics, keeping your workflow on track and your instrument ready for operation. • Rely on consistent performance and sturdy construction designed to deliver repeatable, trustworthy results—even during high sample volumes and demanding schedules.

With the TL2350 Laboratory Turbidimeter, your laboratory can count on precise and reliable turbidity measurements that align with compliance goals. This instrument empowers your team to reach quality benchmarks, supporting consistent results day after day.

主要特点

  • Improved and intuitive design:The TL23 Series’ large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
  • A smart device for more reliable measurements:The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
  • Easy to use. Easy to Be Right:The TL23 Series provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach® makes it easy to Be Right.

技术参数

参数名称说明
AccuracyRatio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU ±10 % of reading from 4000 - 10000 NTU Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Accuracy 3Absorbance: ±0.01 Abs from 0 - 0.5 Abs at 455 nm, ±2% Abs from 0.5 - 1 Abs at 455 nm Transmittance: 2% T from 10 - 100% T at 455 nm
Air PurgeDry nitrogen or instrument grade air (ANSI MC 11.1, 1975) 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max Hose barb connection for 1/8-inch tubing
CertificationsCE, KC, RCM
CommunicationUSB
ComplianceEPA
Data Logging2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D)153 mm x 395 mm x 305 mm
Display17.8 mm (7 in.) color touch screen
Interface2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
Light SourceTungsten filament lamp
Measurement MethodNephelometric
ModelTL2350 EPA
Operating Temperature Range0 - 40 °C
Power Requirements (Amps)3.4 A
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
Range0 - 10000 NTU (EPA)
RangeNTU (Ratio on): 0 - 10000 auto decimal NTU (Ratio off): 0 - 40 EBC (Ratio on): 0 - 2450 auto decimal EBC (Ratio off): 0 - 9.8 Absorbance (auto range): 0 - 1.0 Transmittance (%): 1.0 - 100 Degree (mg /L): 1 - 100
Reading ModesSingle, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
RegulatoryMeets EPA Method 180.1
Repeatability±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Response TimeSignal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample Cell CompatibilityRound cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
Sample Requirements25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F)
Source LampTungsten Lamp
Stabilization TimeRatio on: 30 minutes after start-up Ratio off: 60 minutes after start-up
Storage Conditions-20 to 60 °C
UnitsNTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L
Warranty12 months
Weight3.0 kg
What's included?TL2350 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover

应用领域

Groundwater · Membrane Protection · Municipal Water · QA/QC Lab · Surface Water

同系列其他配置

型号
LPV444.99.00120TL2310 LED Turbidimeter, ISO, 0 - 1000 NTU
LPV444.99.00210TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU
LPV444.99.00320TL2360 LED Turbidimeter, ISO, 0-10000 NTU