Experience Unmatched Efficiency and Reliability with the NH6000sc Ammonia Analyzer: High-Quality Measurements and Predictive Diagnostics for Optimal Performance
Discover the NH6000sc Ammonia Analyzer, an advanced online ammonia analyzer that combines transparent, high-quality measurement technology with exceptional reliability and a swift response time. Designed to handle a wide range of wastewater applications, this analyzer ensures precise and rapid results, including efficient sample preparation. The NH6000sc ammonia analyzer utilizes the gas sensing ammonium Electrode (GSE) measurement procedure, providing highly accurate and reliable ammonia readings. The NH6000sc is the new and improved replacement for the Amtax sc ammonia analyzer, offering enhanced performance and reliability for your ammonia analysis needs.
Environmentally controlled for rugged, outdoor installations, the NH6000sc ammonia analyzer is specifically designed for easy installation at the measurement point. Its gas sensing electrode is equipped with a self-cleaning membrane, minimizing maintenance requirements. The analyzer also features easy access to reagents and wear parts, making it incredibly user-friendly and efficient.
To ensure optimal performance and reliability, the NH6000sc ammonia analyzer must be connected to a digital Hach SC controller. These controllers provide seamless integration and enhanced operational efficiency, making your water analysis processes more streamlined and effective. Additionally, Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance by alerting you to upcoming instrument issues, giving you unwavering confidence in your measurements.
The sample needs to be prepared and filtered before analysis, filtration system is sold separately. Please note that reagents are not included and need to be ordered separately.
主要特点
- Maximize uptime and accuracy with trusted technology:The NH6000sc ammonia analyzer from Hach® uses fast, accurate and trusted GSE technology. The NH6000sc provides reliable measurements with automatic calibration, validation, and cleaning. A verification grab sample improves consistency between online and lab data through an automatic sampling process. Predictive diagnostics and supportive maintenance workflows help you maximize uptime.
- Save time with biannual maintenance:The NH6000sc ammonia analyzer reduced routine user maintenance frequency to only twice per year. Engineered with efficiency in mind, the instrument's streamlined design and optimized reagents make operation simple and user-friendly. With a standard cleaning cycle, the reagents have an extended replacement time of every 6-months.
- Robust and lightweight integrated filtration options:The integrated FX610 filtration system and the more rugged FX620 feature lightweight construction with improved air cleaning and innovative flow detection. These features ensure reliable functionality and reduced operational touchpoints. Plus, you’ll have the ability to remotely check that your sample is consistently supplied to your analyzer to increase confidence in your results.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | With Standard Solution: Measuring range 1: ≤ 1 mg/L: 3% of the measured value + 0.02 mg/L > 1 mg/L: 5% of the measured value + 0.02 mg/L Measuring range 2: 3% of the measured value + 0.05 mg/L Measuring range 3: 3% of the measured value + 1.0 mg/L Measuring range 4: 4.5% of the measured value + 10 mg/L |
| Altitude | 2000 m (6562 ft.) maximum |
| Cable Length | Data cable length: < 50 m (164 ft) Power cable length: < 5 m (16.4 ft) |
| Certifications | CE, UKCA, CMIM, FCC, ISED, certified to UL and CSA safety standards by TÜV |
| Controller Compatibility | Digital SC Controller. Controllers are sold separately. |
| Dimensions | 575 x 991 x 425 mm (22.63 x 39.01 x 16.73 in.) |
| Enclosure Rating | Rating: IP55, NEMA UL50E 3R Material: PUR 66 |
| Filter Configuration | Use e.g. Filtrax |
| Indoor/Outdoor | Indoor or outdoor use |
| Lower Limit of Detection (LOD) | Measuring range 1: 0.02 mg/L NH₄-N Measuring range 2: 0.05 mg/L NH₄-N Measuring range 3: 1 mg/L NH₄-N Measuring range 4: 10 mg/L NH₄-N |
| Material | PUR 66 UV-resistant |
| Measurement Method | Gas sensing electrode (GSE) |
| Measuring Interval | 5, 10, 15, 20 or 30 min. (user adjustable) |
| Number of Channels | 2 |
| Operating Temperature Range | -20 - 45 °C (-4 - 113 °F); 95% relative humidity, non-condensing |
| Options | Flow detection |
| Outputs | Relay, analog outputs, network interface through SC Controller |
| Parameter | Ammonia |
| Permissible Chloride Range | ≤ 1000 mg/L Cl- |
| pH Range | 5 - 9 pH |
| Pollution Degree | 2 |
| Power Supply | Power supplied by the SC controller. With the SC4500, an additional power box is needed. Analyzer and heated drain tubing (powered by analyzer): 115 VAC or 230 VAC |
| Protection Class | Class 1 |
| Range | Measuring range 1: 0.02 - 5.0 mg/L NH₄-N Measuring range 2: 0.05 - 20 mg/L NH₄-N Measuring range 3: 1 - 100 mg/L NH₄-N Measuring range 4: 10 - 1000 mg/L NH₄-N |
| Repeatability | With Standard Solution: Measuring range 1: 3% of the measured value + 0.02 mg/L Measuring range 2: 2% of the measured value + 0.05 mg/L Measuring range 3: 2% of the measured value + 1.0 mg/L Measuring range 4: 2% of the measured value + 10 mg/L |
| Response Time T90 | Measuring range 1: ≤ 0.2 mg/L: 3 measurements required (15 total minutes minimum); > 0.2 mg/L: 1 measurement required (5 total minutes) Measuring range 2: < 5 minutes Measuring range 3: < 5 minutes Measuring range 4: < 5 minutes |
| Sample Flow Rate | 1.0 - 20.0 L/h to the analyzer from the external sample filtration |
| Sample Pressure | 2.5 bar (0.25 mPa) (36.3 psi) maximum |
| Sample Quality | Ultra filtrated or comparable (FX6x0 < 0.45 µm) |
| Sample Temperature | 4 - 40 °C (39 - 104 °F) |
| Special Remarks | The liquid level in the basin must be below the bottom of the analyzer |
| Storage Conditions | -20 - 60 °C (-4 - 140 °F); 95% relative humidity, non-condensing |
| Weight | Approximately 45 kg (99.21 lbs.) without chemicals |
| What's included? | NH6000sc Ammonia Analyzer, Mounting Hardware, User Manual |
应用领域
Industrial Wastewater · Municipal Water · Nutrient Monitoring · Primary Treatment · Secondary Treatment · Tertiary Treatment
同系列其他配置
| 型号 | |
|---|---|
| LXV461.99.00221 | NH6000sc Ammonia Analyzer, 1 channel, for use with 1 external filtrati |
| LXV461.99.00321 | NH6000sc Ammonia Analyzer, 1 channel, for use with 1 external filtrati |
| LXV461.99.01221 | NH6000sc Ammonia Analyzer, 1 channel, includes integrated sample suppl |
| LXV461.99.01321 | NH6000sc Ammonia Analyzer, 1 channel, includes sample supply pump for |
| LXV461.99.02221 | NH6000sc Ammonia Analyzer, 1 channel, includes sample supply pump for |
| LXV461.99.02321 | NH6000sc Ammonia Analyzer, 1 channel, includes sample supply pump for |
| LXV461.99.05221 | NH6000sc Ammonia Analyzer, 2 channels, use 1 external sample filtratio |
| LXV461.99.04221 | NH6000sc Ammonia Analyzer, 2 channels, use 1 external sample filtratio |
资料下载
- Nitrification Optimization in the Real World at Grapevine, TX, WWTP
- Advanced Ammonium/Nitrate-Based Control for Carousel/Oxidation Ditch Activated Sludge Plants
- Geavanceerde regeling op basis van ammonium/ nitraat voor carrousel-/oxidatieslootinstallaties met actief slib
- Control avanzado basado en amonio/nitrato para plantas de lodos activados tipo carrusel/ canal de oxidación
- Fortschrittliche Ammonium-und Nitrat-Überwachung für Belebtschlammanlagen
- Contrôle avancé de l’ammonium et des nitrates dans les stations à boues activées de type carrousel/fossé d’oxydation
- Comparison : NH6000sc Ammonia Analyzer vs. Amtax sc Ammonia Analyzer
- Comparison: FX6 vs. Filtrax Robust and lightweight filtration options
Похожие
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
CPVC Insertion Mounting Hardware 2", pHD Series
COVER-SERVICE REPLACEMENT
HACH