Приборы · Инжиниринг · Комплектация · ПЛК
0755-82221901 sales@ainstru.com
MTC10103
Семейство продуктов: IntelliCAL ORP Probes
IntelliCAL MTC101 Laboratory Low Maintenance Gel Filled ORP/RedOx Electrode, 3 m Cable
HACH MTC10103
IntelliCALⓇ MTC101 is a digital, combination oxidation reduction potential (ORP/Redox) electrode with a non-refillable, gel-electrolyte reference and built-in temperature sensor. MTC101 has low mainte

产品概述

IntelliCALⓇ MTC101 is a digital, combination oxidation reduction potential (ORP/Redox) electrode with a non-refillable, gel-electrolyte reference and built-in temperature sensor. MTC101 has low maintenance needs thanks to a non-refillable gel-filled single open reference junction. The laboratory version of this metallic electrode is shockproof with its epoxy plastic body protecting down to the platinum sensing element. The Electrode is available with a 3 or 1 m cable. The MTC101 electrode is ideal for measuring ORP/RedOx absolute mV values in wastewater, drinking water and aqueous media applications. The MTC101 is not suitable for use with organic solvents.

主要特点

  • Provides fast, stable response in a variety of applications:IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large open reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
  • Ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
  • User alerted when re-calibration is needed:No guesswork needed to provide most reliable and accurate results with each measurement.
  • Can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters

技术参数

参数名称说明
Accuracy±0.02 mV or 0.05%, whichever is greater
Cable Length3 m (9.84 ft)
Electrode TypeNon-Refillable Gel Reference Element
InstrumentSensor & Electrodes
JunctionOpen Junction
Kit?No
Length175 mm (6.89 in.)
Method TypeLaboratory: Non-Refillable Gel Reference Element
ParameterORP
Probe TypeStandard
Product KitModel: MTC301 Accessories Included: None
Range±1200 mV
Reference TypeAg/AgCl
Resolution±0.1 mV
Sample depth20 mm (0.79 in.)
Sensor materialEpoxy
Sensor TypePlatinum disc
Special FeaturesFlat disc sensor for easy cleaning.
Temperature Accuracy±0.3 °C (±0.54 °F)
Temperature Range0 - 80 °C (32 - 176 °F)
Temperature Resolution0.1 °C (0.18 °F)
Test requirementsParameter Needed: ORP Minimum Sample Depth (mm): 20
ThermistorATC
Warranty6 months
Weight0.15 kg
What's included?IntelliCAL MTC101 Laboratory ORP/RedOx electrode with storage soaker bottle, 3 m cable, Test certificate, and Basic User Manual.

应用领域

Municipal Water · Potable Water · Production Water · Surface Water

同系列其他配置

型号
MTC10105IntelliCAL MTC101 Field Low Maintenance Gel Filled ORP/RedOx Electrode
MTC10110IntelliCAL MTC101 Field Low Maintenance Gel Filled ORP/RedOx Electrode
MTC10115IntelliCAL MTC101 Field Low Maintenance Gel Filled ORP/RedOx Electrode
MTC10130IntelliCAL MTC101 Field Low Maintenance Gel Filled ORP/RedOx Electrode
MTC10101IntelliCAL MTC101 Laboratory Low Maintenance Gel Filled ORP/RedOx Elec
MTC30101IntelliCAL MTC301 Laboratory General Purpose Refillable ORP/RedOx Elec
MTC30103IntelliCAL MTC301 Laboratory General Purpose Refillable ORP/RedOx Elec

资料下载

Моделей: 8 · свернуть