Приборы · Инжиниринг · Комплектация · ПЛК
0755-82221901 sales@ainstru.com
TNT810
Семейство продуктов: TOC TNTplus Vial Tests
TOC TNTplus Vial Test, LR (1.5-30.0 mg/L C), 25 Tests
HACH TNT810
TOC TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. TNT810 has a range of 1.5 - 30.0 mg/L C and is designed for wastewater

产品概述

Expert Low Range TOC test made simple.

TOC TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. TNT810 has a range of 1.5 - 30.0 mg/L C and is designed for wastewater, surface water, process waters, and is USEPA approved for total organic carbon in drinking water. For determination of Total Organic Carbon (TOC) by the Direct Method which follows an acid persulfate digestion to oxidize TOC to carbon dioxide (CO2). The generated CO2 passes through a gas-permeable membrane into an indicator solution is measured spectrophotometrically.

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
  • Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.

技术参数

参数名称说明
Digestion RequiredYes
EPA compliantYes
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NameDirect Method
Method Number10267
Number of tests25
ParameterTOC (Total Organic Carbon)
PlatformTNT plus™
Range1.5 - 30.0 mg/L C
Sample RequirementsThe pH of the water sample must be between pH 3 - 10. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F).