Expert Ultra Low Range Ammonia test made simple
Ammonia TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, every time. For determination of Ammonia Nitrogen by the Salicylate Method using TNTplus vials. Hach Method 10205. Scope and Application Robust ammonia reagents can be used to determine ammonia levels in a variety of samples including drinking water and wastewater, as well as environmental waters and watershed protection monitoring. Product Details • Ultra Low Range: 0.015 - 2.00 mg/L NH₃-N • 25 tests/package • EPA compliant Easy to Use Simply add sample to the Ammonia reagent vial, invert the cap, and read in your Hach spectrophotometer. No more dealing with traditional mercury-based chemistry and large amounts of waste and glassware! Please note: for regulatory reporting, the EPA formatted Hach Approved Method 10205 must be followed.
主要特点
- Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
- Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
- Documented shelf life and COA:The 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.
技术参数
| 参数名称 | 说明 |
|---|---|
| According to standard | EPA 350.1, EPA 351.1, EPA 351.2 |
| EPA compliant | Yes |
| Instrument | DR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000 |
| Method Name | Salicylate |
| Method Number | 10205 |
| Number of tests | 25 |
| Parameter | Ammonia, Nitrogen |
| Platform | TNT plus™ |
| Range | 0.015 - 2.00 mg/L NH₃-N |
| Storage Conditions | 2 - 8 °C (keep refrigerated) |
| Truecal | Yes |
应用领域
Industrial Wastewater · Influent for Wastewater · Nutrient Monitoring · Primary Treatment · QA/QC Lab · Secondary Treatment · Source Water · Tertiary Treatment
同系列其他配置
| 型号 | |
|---|---|
| TNT832 | Ammonia TNTplus Vial Test, HR (2-47 mg/L NH₃-N), 25 Tests |
| TNT834 | Ammonia TNTplus Vial Test, UHR+ (100-1800 mg/L NH₃-N), 25 Tests |
| TNT829 | Ammonia TNTplus Vial Test, ULR+ (0.50 - 5.00 mg/L NH₃-N), 25 Tests |
| TNT837 | Ammonia TNTplus Vial Test, HR+ (10 - 100 mg/L NH₃-N), 25 Tests |
| TNT831 | Ammonia TNTplus Vial Test, LR (1-12 mg/L NH₃-N), 25 Tests |
| TNT833 | Ammonia TNTplus Vial Test, UHR (47-130 mg/L NH₃-N), 25 Tests |
资料下载
- Complete Water Analysis for the Food Industry
- Determination of Ammonia TNTplus
- TNTplus Vial Tests: Expert testing made simple
- Recognized Results Based on Quality Assurance and Quality Control
- How temperature affects measurement results
- Selecting the Right Ammonia Method for Your Lab: Choosing between Colorimetric and Gas Sensing Ion Selective Electrode Methodologies
- TNTplus 830 Ammonia Measuring Range Exceedance
- TNTplus Brochure - Vietnamese
Похожие
HACHPhosphoric Acid Solution, 1.0 Molar 5 Gallon
HACHAmino acid reagent powder pillows for LR silica, 25 mL, pk/1000
Nutrients Basic Reagent Set, TNTplus
HACHRapid Silver Reagent Powder Pillows, pk/100
HACHRochelle Salt-PVA Reagent, 500 mL
HACHToluene, 4 L
HACHSodium carbonate solution, 500 mL
HACH