TNT830
Семейство продуктов: Ammonia TNTplus Vial Tests
Ammonia TNTplus Vial Test, ULR (0.015 - 2.00 mg/L NH₃-N), 25 Tests
HACH TNT830
Expert Ultra Low Range Ammonia test made simple

产品概述

Expert Ultra Low Range Ammonia test made simple

Ammonia TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, every time. For determination of Ammonia Nitrogen by the Salicylate Method using TNTplus vials. Hach Method 10205. Scope and Application Robust ammonia reagents can be used to determine ammonia levels in a variety of samples including drinking water and wastewater, as well as environmental waters and watershed protection monitoring. Product Details • Ultra Low Range: 0.015 - 2.00 mg/L NH₃-N • 25 tests/package • EPA compliant Easy to Use Simply add sample to the Ammonia reagent vial, invert the cap, and read in your Hach spectrophotometer. No more dealing with traditional mercury-based chemistry and large amounts of waste and glassware! Please note: for regulatory reporting, the EPA formatted Hach Approved Method 10205 must be followed.

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
  • Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
  • Documented shelf life and COA:The 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.

技术参数

参数名称说明
According to standardEPA 350.1, EPA 351.1, EPA 351.2
EPA compliantYes
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NameSalicylate
Method Number10205
Number of tests25
ParameterAmmonia, Nitrogen
PlatformTNT plus™
Range0.015 - 2.00 mg/L NH₃-N
Storage Conditions2 - 8 °C (keep refrigerated)
TruecalYes

应用领域

Industrial Wastewater · Influent for Wastewater · Nutrient Monitoring · Primary Treatment · QA/QC Lab · Secondary Treatment · Source Water · Tertiary Treatment

同系列其他配置

型号
TNT832Ammonia TNTplus Vial Test, HR (2-47 mg/L NH₃-N), 25 Tests
TNT834Ammonia TNTplus Vial Test, UHR+ (100-1800 mg/L NH₃-N), 25 Tests
TNT829Ammonia TNTplus Vial Test, ULR+ (0.50 - 5.00 mg/L NH₃-N), 25 Tests
TNT837Ammonia TNTplus Vial Test, HR+ (10 - 100 mg/L NH₃-N), 25 Tests
TNT831Ammonia TNTplus Vial Test, LR (1-12 mg/L NH₃-N), 25 Tests
TNT833Ammonia TNTplus Vial Test, UHR (47-130 mg/L NH₃-N), 25 Tests