Cerabar S PMP71 诊断代码
共 60 条诊断代码 · 来源手册 BA00274PZH_1413.pdf
对应产品:Cerabar S PMP71 (查看参数与选型)
| 代码 | 信号 | 简述 | 行为 | 页码 |
|---|---|---|---|---|
| 101 | F | Sensor electronic EEPROM error | Alarm | P139 |
| 102 | M | Checksum error in EEPROM: peakhold segment | Warning | P139 |
| 106 | C | Downloading - please wait | Warning | P139 |
| 110 | F | Checksum error in EEPROM: configuration segment /EEPROM 错误:组态字段 | Alarm | P139 |
| 113 | F | ROM failure in transmitter electronic | Alarm | P139 |
| 115 | S | Sensor overpressure | Warning | P140 |
| 116 | M | Download error, repeat download | Warning | P140 |
| 120 | S | Sensor low pressure | Warning | P140 |
| 121 | F | Checksum error in factory segment of EEPROM | Alarm | P140 |
| 122 | F | Sensor not connected | Alarm | P140 |
| 130 | F | EEPROM is defect. | Alarm | P140 |
| 131 | F | Checksum error in EEPROM: min/max segment | Alarm | P140 |
| 132 | F | Checksum error in totalizer EEPROM | Alarm | P140 |
| 133 | F | Checksum error in History EEPROM | Alarm | P140 |
| 602 | C | Linearisation curve not monotone | Warning | P140 |
| 604 | C | Linearisation table not valid. Less than 2 points or points too close | Warning | P141 |
| 613 | C | Simulation is active | Warning | P141 |
| 620 | S | Current output out of range | Warning | P141 |
| 700 | M | Last configuration not stored | Warning | P141 |
| 701 | C | Measuring chain config. exceeds sensor range | Warning | P141 |
| 702 | M | HistoROM data not consistent. | Warning | P141 |
| 703 | F | Measurement error | Alarm | P141 |
| 704 | C | Measurement error | Alarm | P141 |
| 705 | F | Measurement error | Alarm | P141 |
| 706 | M | Configuration in HistoROM and device not identical | Warning | P142 |
| 707 | C | X-VAL. of lin. table out of edit limits. | Alarm | P142 |
| 710 | C | Set span too small. Not allowed. | Warning | P142 |
| 711 | C | LRV or URV out of edit limits | Alarm | P142 |
| 713 | C | 100% POINT level out of edit limits | Alarm | P142 |
| 715 | S | Sensor over temperature | Warning | P142 |
| 716 | F | Process isolating diaphragm broken | Alarm | P142 |
| 717 | S | Transmitter over temperature | Alarm | P142 |
| 718 | S | Transmitter under temperature | Alarm | P143 |
| 719 | C | Y-VAL of lin. table out of edit limits | Alarm | P143 |
| 720 | S | Sensor under temperature | Warning | P143 |
| 721 | C | ZERO POSITION level out of edit limits | Alarm | P143 |
| 722 | C | EMPTY CALIB. | Alarm | P143 |
| 723 | C | MAX. FLOW out of edit limits | Alarm | P143 |
| 725 | F | Sensor connection error, cycle disturbance | Alarm | P143 |
| 726 | S | Sensor temperature error - overrange | Warning | P143 |
| 727 | S | Sensor pressure error - overrange | Warning | P144 |
| 728 | F | RAM error | Alarm | P144 |
| 729 | F | RAM error | Alarm | P144 |
| 730 | S | LRV user limits exceeded | Warning | P144 |
| 731 | S | URV user limits exceeded | Warning | P144 |
| 732 | S | LRV Temp. User limits exceeded | Warning | P144 |
| 733 | S | URV Temp. User limits exceeded | Warning | P144 |
| 736 | F | RAM error | Alarm | P144 |
| 737 | F | Measurement error | Alarm | P144 |
| 738 | F | Measurement error | Alarm | P144 |
| 739 | F | Measurement error | Alarm | P145 |
| 740 | M | Calculation overflow, bad configuration | Warning | P145 |
| 741 | C | TANK HEIGHT out of edit limits | Alarm | P145 |
| 742 | F | Sensor connection error | Alarm | P145 |
| 743 | F | Electronic PCB error during initialisation | Alarm | P145 |
| 744 | F | Main electronic PCB error | Alarm | P145 |
| 745 | M | Sensor data unknown | Warning | P145 |
| 746 | C | Sensor connection error - initialising | Warning | P145 |
| 747 | F | Sensor software not compatible to electronics | Alarm | P145 |
| 748 | F | Memory failure in signal processor | Alarm | P146 |