Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

Technical Information

50103475(71039686) Vortex Flowmeter Amplifier Board Correct Use, Configuration, Replacement, Selection, Application and Precautions Maintenance
2024-02-01Ainstru

50103475(71039686) Vortex Flowmeter Amplifier Board Correct Use, Configuration, Replacement, Selection, Application and Precautions Maintenance

50103475(71039686) vortex flowmeter amplifier plate in posit…

TMT80-AA | TMT80-1014/0 Correct Use Configuration Replacement Selection Application and Precautions Maintenance
2024-02-01Ainstru

TMT80-AA | TMT80-1014/0 Correct Use Configuration Replacement Selection Application and Precautions Maintenance

TMT80-AA | TMT80-1014/0 E H The most commonly used 4-20ma ou…

51501218 board transmitter Inductive modular display Proper use Configuration Replacement Selection Application and precautions Maintenance
2024-02-01Ainstru

51501218 board transmitter Inductive modular display Proper use Configuration Replacement Selection Application and precautions Maintenance

51501218 transmitter inductive module display in position 50…

Correct use, configuration, replacement, selection, application and precautions for maintenance of the power board of the 71161133 transmitter
2024-02-01Ainstru

Correct use, configuration, replacement, selection, application and precautions for maintenance of the power board of the 71161133 transmitter

71161133 transmitter power board in stock for CPM223 CLM223 …

TMT182-BBAAAZ Selection Application Scenarios and Precautions Maintenance Details
2024-01-31Ainstru

TMT182-BBAAAZ Selection Application Scenarios and Precautions Maintenance Details

TMT182-BBAAAZ selection application scenarios and precaution…

Plug-in Thermowell Selection G1/2 M20 * 1.5
2024-01-25Ainstru

Plug-in Thermowell Selection G1/2 M20 * 1.5

Plug-in Thermowell Selection G1/2 M20 * 1.5

E H Flowmeter to turn red. Successful Case Chart of Instrument Maintenance, Inspection, Setting and Debugging at Customer's Requirements
2024-01-19Ainstru

E H Flowmeter to turn red. Successful Case Chart of Instrument Maintenance, Inspection, Setting and Debugging at Customer's Requirements

E H Flowmeter Turning Red According to Customer's Requiremen…

CDC40103 Hash Conductivity Electrode
2024-01-18Ainstru

CDC40103 Hash Conductivity Electrode

CDC40103 Hash Conductivity Electrode

PHC10103 HQ11D Hash PH Meter Electrode
2024-01-18Ainstru

PHC10103 HQ11D Hash PH Meter Electrode

PHC10103 Hash PH Electrode Parameter Range: pH: 0~14pH ORP:-…

LDO10103 standard electrode: (3 m cable) rugged electrode
2024-01-18Ainstru

LDO10103 standard electrode: (3 m cable) rugged electrode

LDO10103 standard electrode: (3 m cable) rugged electrode