Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FQG62 Gamma射线仪表源盒

FQG62 Gamma射线仪表源盒

射线仪表源盒

The FQG62 source container is designed to hold the radioactive source during radiometric point level detection, continuous level and density measurement. The radiation is emitted almost unattenuated in one direction only, and is damped in all other directions. This guarantees highest safety for the personnel and a reliable measurement.
Compare

Continuous / Liquids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
Approximately 87kg
Specialities Manual or pneumatic switch-on/ switch-off
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Continuous / Solids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
Approximately 87kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F ...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Density

Measuring Principle Radiometric Density
Characteristic / Application Source container
Emission angle: 5/ 20/ 40 degrees
87kg
Ambient temperature -20 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure Any
Wetted parts Non-contact
Hygienic Non-contact
Specialities Control area calculation with Applicator

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
Approximately 87kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
Approximately 87kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

The FQG62 source capsule contains the radiation source and is used for radiometric limit detection as well as continuous level and density measurement. The radiation is emitted almost without attenuation in only one direction and is shielded in all other directions, ensuring maximum personnel safety and reliable measurement.

Benefits
Lightweight source capsule with near-spherical design for excellent shielding
Safe and convenient source replacement.
Meets the highest safety class (DIN 25426/ISO 2919, typical category C66646).
One-piece source capsule, simple installation.
Various radiation angles for optimum application results
Manual or pneumatic opening and closing
Switch position fixed by padlock, cylinder lock or safety bolt

Applications
The FQG62 source capsule is used to house the radiation source during radiometric limit detection as well as continuous level and density measurement. The radiation is emitted almost without attenuation in only one direction and is shielded in all other directions, ensuring maximum personnel safety and reliable measurement.

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: Endress+Hauserpublic information from the website

市政污水处理

市政污水处理污水处理厂 · 放射性应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 放射性应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 放射性应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 放射性应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。