Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CPS71 Analog pH sensor

CPS71  Analog pH sensor

模拟式PH电极

Configurable Models 12 models
Glass electrode for food and life sciences industries
Compare

pH

Measuring Principle Potentiometric
Application Hygienic and sterile applications, process
Characteristic - resistant against reference poisoning - CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside - version upside-down installation available - pressurized reference (6 bar) available
Measuring range pH 0-14
Measuring principle - ceramic diaphragm - ion-trap
Design - All shaft lengths with temperature sensor - Memosens - advanced gel technology
Material glass / ceramic
Dimension Diameter: 12mm (0.46inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature -15°C ... 140°C
(5°F - 284°F)
Process pressure max. 13 bar
(188 psi)
Temperature sensor optional with integrated Pt100 or Pt1000
Ex certification Simple operational equipment, no certification necessary.
Connection TOP68 connection head
Ingress protection IP 68
Certificates, declarations and approvals 3A, biocompatibility

Field of application
Ceragel CPS71 is the analog specialist for pH measurement in sterile and hygienic applications. Its state-of-the-art gel is poison resistant and guarantees stable measurement even in flowing media or low conductivity. The sensor is sterilizable, autoclavable and non-toxic assuring highest safety of your products.
Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
- Food industry
Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas

 

Benefits
Suitable for CIP/SIP and autoclaving maintaining high accuracy
Sensor resists strong acids and bases and high organic loads
Certified biocompatibility, no cytotoxicity
Free from animal-based materials and from acrylamide

 

 

Measuring Principle Potentiometric
Application Hygienic and sterile applications, process
Characteristic - resistant against reference poisoning - CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside - version upside-down installation available - pressurized reference (6 bar) available
Measuring range pH 0-14
Measuring principle - ceramic diaphragm - ion-trap
Design - All shaft lengths with temperature sensor - Memosens - advanced gel technology
Material glass / ceramic
Dimension Diameter: 12mm (0.46inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature -15°C ... 140°C
(5°F - 284°F)
Process pressure max. 13 bar
(188 psi)
Temperature sensor optional with integrated Pt100 or Pt1000
Ex certification Simple operational equipment, no certification necessary.
Connection TOP68 connection head
Ingress protection IP 68
Additional certifications 3A, biocompatibility
Model Name
CPS71-1TB2ESA 模拟式pH电极
CPS71-1TB2GSA 模拟式pH电极
CPS71-1TC2ESA 模拟式pH电极
CPS71-1TC2GSA 模拟式pH电极
CPS71-2TB2ESA 模拟式pH电极
CPS71-2TC2ESA 模拟式pH电极
CPS71-2TP2ESA 模拟式pH电极
CPS71-2TU2ESA 模拟式pH电极
CPS71-3TB2ESA 模拟式pH电极
CPS71-3TC2ESA 模拟式pH电极
CPS71-3TP2ESA 模拟式pH电极
CPS71-3TU2ESA 模拟式pH电极
市政污水处理

市政污水处理污水处理厂 · PH应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · PH应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · PH应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · PH应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。