PH电极
Technical Data
ComparepH
| Measuring Principle | |
| Application | Chemical industry, pulp and paper, primaries and metal, mining, minerals & metals |
| Characteristic | Unbreakable Useable in highliest clogging media, e.g. suspended solides, dispersion, precipitation reaction Needs min. conductivity of >500µS/cm |
| Reference | Stabilized gel reference system |
| Measuring range | pH 0 to 14 |
| Material | Sensor shaft: PEEK Sealing: FFKM |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.72, 8.86, 14.2 and 16.7 inch) |
| Process temperature | -15 to 110 °C (5 to 230 °F) |
| Process pressure | Max. 11 bar abs. at 100 °C (Max. 159.5 psi at 212 °F) |
| Temperature sensor | Pt1000 |
| Connection | Inductive, digital connection head with Memosens technology |
| Ingress protection | IP 68 (10 m (33 ft) water column, 25 °C (77 °F), 45 days) |
The Memosens CPS97D is the specialist for measuring fibrous media or media with high suspended solids concentration (e.g. dispersions, precipitants, emulsions). The electrode shaft does not break and has a long service life; the open aperture enables reliable measurement under harsh conditions. In addition, the Memosens digital technology offers maximum process and data integrity with simple operation. The electrode is moisture- and corrosion-resistant, allows laboratory calibration and enables predictive maintenance.
Advantages
The sensor does not break, guaranteeing maximum product safety
Open aperture design, suitable for measuring heavily contaminated media
Chemically stable reference gel for long-term stable measurement results
Allows measurement at low temperatures
Long calibration intervals, low maintenance effort
Non-contact inductive signal transmission with maximum process safety
Stores sensor and process parameters, allowing predictive maintenance
Field of application
• Chemical processes
• Pulp and paper industry
• Contaminated media and suspended solids
- dispersions
- precipitants
- emulsions
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products you wish to compare in the fields below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
A
Source:Endress+Hauserpublic information from the website
Case Studies
市政污水处理污水处理厂 · PH应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · PH应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · PH应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · PH应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。