Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CCS51E digital residual chlorine sensor

CCS51E digital residual chlorine sensor

数字式余氯传感器

Configurable Models 45 models
CCS51E digital sensor, suitable for drinking water, pool water, process water, and utility applications in various industries
Compare

Disinfection

Measuring Principle Free chlorine
Application Ensuring reliable disinfection in drinking water
Process water
Dosing disinfectant efficiently in pool water
Detect the absence or presence of free chlorine in Utilities
Guarantee food safety and provide hygienic packaging and bottling
Characteristic Amperometric measurement of dissolved free chlorine
Measuring range Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl
Measuring method Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode
Design Closed amperometric 2-electrode measuring cell with PVDF membrane
Material Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF
Sealing ring: FKM
Dimension Diameter: 25 mm (0.98 inch)
Length: 161 mm (6.34 inch)
Process temperature 0 to 55 °C (32 to 130 °F), non-freezing
Process pressure Max. 1 bar (max. 14.5 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens

The Memosens CCS51E digital free chlorine sensor quickly outputs stable measured values in drinking water, pool water, process water and utility applications. The sensor quickly outputs free chlorine measured values and requires only a small water sample. This ensures efficient process control and safe plant operation. The CCS51E uses Memosens 2.0 digital technology, guaranteeing high process safety and data integrity with simple device operation. It genuinely supports the implementation of predictive maintenance and IIoT applications.

Advantages

Compared to the colorimetric measuring principle, membrane-covered sensors have lower maintenance requirements, significantly reducing operating costs.

Extended uptime: allows laboratory pre-calibration of the sensor, true plug-and-play in the field, and effectively shortens the polarization time with Memosens 2.0 digital technology.

Fast response (t90 < 25 seconds), precise display of the process status, allowing the user to take timely measures in response to process changes and implement process control efficiently.

High process safety and efficient disinfectant dosing: long-term stable output of high-precision measured values, supports continuous process monitoring and flexible adjustment of the disinfectant dosage on demand.

Wide range of applications and broad measuring range: from trace free chlorine measurement to applications with free chlorine concentrations up to 200 mg/l.

Used with Liquiline multiparameter transmitters to simultaneously measure other relevant water analysis parameters such as pH and ORP.

Field of application

The Memosens CCS51E digital free chlorine sensor is suitable for measurement applications in all kinds of water quality:

Drinking water: guarantees the disinfection effect

Utilities: detecting the free chlorine concentration to avoid losses

Process water: ensures safe and hygienic food packaging and bottling processes

Pool water: ensures proper dosing of disinfectant
 

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

 

Source:Endress+Hauserpublic information from the website

Model Name
CCS51E-AA11ADN0 数字式余氯传感器
CCS51E-AA11ADNA 数字式余氯传感器
CCS51E-AA11ADNB 数字式余氯传感器
CCS51E-AA11ADNC 数字式余氯传感器
CCS51E-AA11ADND 数字式余氯传感器
CCS51E-AA11BFN0 数字式余氯传感器
CCS51E-AA11BFNA 数字式余氯传感器
CCS51E-AA11BFNB 数字式余氯传感器
CCS51E-AA11BFNC 数字式余氯传感器
CCS51E-AA11BFND 数字式余氯传感器
CCS51E-AA11CJN0 数字式余氯传感器
CCS51E-AA11CJNA 数字式余氯传感器
CCS51E-AA11CJNB 数字式余氯传感器
CCS51E-AA11CJNC 数字式余氯传感器
CCS51E-AA11CJND 数字式余氯传感器
CCS51E-CD11ADN0 数字式余氯传感器
CCS51E-CD11ADNA 数字式余氯传感器
CCS51E-CD11ADNB 数字式余氯传感器
CCS51E-CD11ADNC 数字式余氯传感器
CCS51E-CD11ADND 数字式余氯传感器
CCS51E-CD11BFN0 数字式余氯传感器
CCS51E-CD11BFNA 数字式余氯传感器
CCS51E-CD11BFNB 数字式余氯传感器
CCS51E-CD11BFNC 数字式余氯传感器
CCS51E-CD11BFND 数字式余氯传感器
CCS51E-CD11CJN0 数字式余氯传感器
CCS51E-CD11CJNA 数字式余氯传感器
CCS51E-CD11CJNB 数字式余氯传感器
CCS51E-CD11CJNC 数字式余氯传感器
CCS51E-CD11CJND 数字式余氯传感器
CCS51E-UR11ADN0 数字式余氯传感器
CCS51E-UR11ADNA 数字式余氯传感器
CCS51E-UR11ADNB 数字式余氯传感器
CCS51E-UR11ADNC 数字式余氯传感器
CCS51E-UR11ADND 数字式余氯传感器
CCS51E-UR11BFN0 数字式余氯传感器
CCS51E-UR11BFNA 数字式余氯传感器
CCS51E-UR11BFNB 数字式余氯传感器
CCS51E-UR11BFNC 数字式余氯传感器
CCS51E-UR11BFND 数字式余氯传感器
CCS51E-UR11CJN0 数字式余氯传感器
CCS51E-UR11CJNA 数字式余氯传感器
CCS51E-UR11CJNB 数字式余氯传感器
CCS51E-UR11CJNC 数字式余氯传感器
CCS51E-UR11CJND 数字式余氯传感器
市政污水处理

市政污水处理污水处理厂 · 消毒应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 消毒应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 消毒应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 消毒应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。