Configurable Models 15 models
Trend-setting, highly modular and intrinsically safe temperature sensor iTHERM ModuLine TM131 – for a wide range of industrial applications.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
with neck or iTHERM QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with iTHERM StrongSens, iTHERM QuickSens insert
for fast response times
Thermowell / protection tube welded protection tube or to be used with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert Thermowell:
9x1,25 mm
11x2 mm
12x2,5 mm
14x2 mm
16x3,5
1/4" SCH80
1/2" SCH80
1/2" SCH40
Max. immersion length on request up to 4.500,0 mm (177'')
Material protection tube/ thermowell 316 (1.4401)
316L (1.4404)
316Ti (1.4571)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Alloy 446 (1.4749)
Alloy 321 (1.4541)
Sheath PTFE
Sheath Tantal
Process connection Male thread:
G3/8, G1/2", G3/4", G1"
NPT1/2", NPT3/4", NPT 1"
M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
R1/2", R3/4"
Female thread:
M20x1.5, M24x1.5
NPT1/2"
Cap-nut:
M20x1.5, G1/2", G3/4"
Compression fitting:
NPT1/2", G1/2", G1"
Flange:
DN15 PN40 B1, C
DN25 PN20, PN40, PN100 B1, B2, C
DN40 PN40 B1
DN50 PN40 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1 1/2" 150 RF
ASME 2" 150 RF
ASME 2" 300 RF
Tip shape straight
reduced
tapered
optimized for quick response times
Surface roughness Ra < 0.76 μm (0.03 μin)
Operating temperature range PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 TF iTHERM QuickSens:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration up to 100 bar
Accuracy Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response time fastest response time with thermowell t90 starting at below 10 s
depending on configuration
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ec, Ex tc
ATEX IECEx Ex ta/tb, Ex ia, Ex db
CSA C/US IS, NI, XP, DIP
INMETRO Ex ia, Ex d, Ex tb
NEPSI Ex ia, Ex d, Ex tD , Ex DB,
EAC Ex d, Ex ta/tb, Ex ia
UKCA Ex ia, Ex nA, Ex tc
KC Ex ia
IND Ex
Certification SIL, MID, DNV/GL

Resistance thermometers or thermocouples with integral thermowell, or for use in field-installed thermowells. Optionally installed in modular transmitters supporting common communication protocols - Bluetooth® technology, especially with iTHERM QuickNeck, tool-free recalibration, vibration-resistant, short sensor response time, with thermowell technology (iTHERM StrongSens, QuickSens), explosion-protection certified, higher measuring accuracy and higher reliability.

Benefits
Second process barrier with fault indication provides useful health status information
iTHERM armored insert: unique worldwide, fully automated production. Fully traceable, consistently high product quality for reliable measured values
iTHERM QuickSens: fastest response time of only 1.5 seconds for optimized process control
iTHERM StrongSens: extremely high vibration resistance (> 60 g) for permanent plant safety
iTHERM QuickNeck: extremely simple recalibration without additional tools, saving cost and time
iTHERM TA30x: various terminal head models for simpler operation and lower installation and maintenance costs
International approvals: ATEX, IECEx, CSA C US and NEPSI explosion protection

Application areas
Wide range of applications
Measuring range: –200...+1100 °C (–328...+2012 °F)
Maximum pressure: 100 bar (1450 psi)
Highest degree of protection: IP 68
Maximum vibration resistance of 60 g.
Simpler maintenance (sensor replacement without interrupting the process), simple and safe recalibration of the measuring point

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
TM131-8JBBJDB1BX1AGAC1AA1AA1 热电阻温度计
TM131-AAADCCA2AA4CAAB2AA1AA1 热电阻温度计
TM131-AABBCCB2BX1AKBD3CA1AA1 热电阻温度计
TM131-AABBCCB2BX1AKBD3DA1AA1 热电阻温度计
TM131-AABBCCB2BX1AKNG3CA1AA1 热电阻温度计
TM131-AABBCCC1BX1AFAC2BA1AA1NQ 热电阻温度计
TM131-AABBCCC4BX2AXBC2AA1AA1 热电阻温度计
TM131-AABBCEB2BX1AKOG3DD1AA1+GFZ1 热电阻温度计
TM131-AABBJDB2BB2AGCB3DD1AA1GFLANQ 热电阻温度计
TM131-AABBJHB2DB1AGEC3CA2AA1 热电阻温度计
TM131-AABBPAD2BX1AGBC3AA1AA1+LJNQ 热电阻温度计
TM131-AABCCEB2BX2BJDC2AA1AA1+NQ 热电阻温度计
TM131-AADAAAB2DA7AAEC3CA2AA1 热电阻温度计
TM131-AADAAAB2DB2AAEE3CA2AA1 热电阻温度计
TM131-CABBCCB1BA4AFBB2HA1AA1 热电阻温度计
市政污水处理

市政污水处理污水处理厂 · 热电阻应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热电阻应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热电阻应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热电阻应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。