Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

TR24 热电阻温度计

TR24 热电阻温度计

热电阻温度计

The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Compare

Thermometer

Measuring Principle
Characteristic / Application metric style
modular temperature assembly
process connection as compression fitting
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 3,0 mm (0,12'')
6,0 mm (0,24'')
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell 1.4404 (316L)
Process connection compression fitting:
G1/2"
NPT1/2"
weld in version
Tip shape straight
reduced
Surface roughness Ra Not defined
Operating temperature range PT 100:
-200 °C …600 °C
(-328 °F …1112 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Accuracy class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time depending on configuration
t50 = 2 s
t90 = 5 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II1G Ex ia IIC T6
ATEX II 3 G Ex nA IIC T6, II3D
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
IECEx Ex ia IIC T6 Ga/Gb
NEPSI Ex nA IIC T6
Certification Gost Metrology
SIL (transmitter only)

The highly modular, rugged thermometer is suited to virtually all industrial applications. Devices with an optional head transmitter are compatible with all common communication protocols and ready to install and use, offering greater measuring accuracy and reliability compared to directly wired sensors. Various process connections, sizes and materials provide application flexibility.

Benefits:

Modular design with a standard terminal head per DIN EN 50446 and customer-specified immersion length for high flexibility

  • High insert compatibility, design in accordance with DIN 43772

  • Short conical tip for faster response time

  • Protection types for hazardous locations: intrinsically safe (Ex ia), non-sparking (Ex nA)

  • Easy head transmitter selection: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

市政污水处理

市政污水处理污水处理厂 · 热电阻应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热电阻应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热电阻应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热电阻应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。