Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CPA474 伸缩式支架

CPA474 伸缩式支架

伸缩式支架

The Cleanfit CPA474 retractable assembly is designed for applications which require safe separation from the process and contain media that could affect stainless steel. It offers highest operating comfort: You can replace sensors and even service the assembly while the process is running. The optional electric or pneumatic control system enables automated cleaning and calibration even in difficult processes.
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Chemical industry, wastewater, industrial water, power plants, refuse incinerators
Installation Retractable holder with ball valve
Characteristic Open and closed tank, piping (min. DN80)
Design Manual or pneumatic
Manual or pneumatic ball valve
Can be fully automated with CPC30 / 300
Integrated rinse chamber with connection G1/4" or NPT1/4"
Material Seals: EPDM / FPM / perfluoroelastomer
Electrode holder: PP / PEEK / PVDF
Ball valve: PP / PVDF
Inlet safety seal: PVDF, PTFE, Viton®
Outlet safety seal: PVDF
Rinse connection socket: PVDF
Dimension Immersion depth: 71 to 207 mm (2.8 to 8.15 inch)
Process temperature PA version: max. 80 °C (max. 176 °F)
Stainless steel pressure cylinder: max. 120 °C (248 °F)
Process pressure PA pressure cylinder: max. 6 bar (87 psi)
Stainless steel pressure cylinder: max. 10 bar (145 psi) at 40 °C (104 °F)
Connection Process connection DN50, ANSI 2"

pH

Measuring Principle Potentiometric
Application Chemical industry, wastewater, industrial water, power plants, refuse incinerators
Installation Retractable assembly with ball valve
Characteristic Open and closed tank, piping (min. DN80)
Design Manual or pneumatic
Manual or pneumatic ball valve
Can be fully automated with CPC30 / 300
Integrated rinse chamber with connection G1/4" or NPT1/4"
Material Seals: EPDM / FPM / perfluoroelastomer
Electrode holder: PP / PEEK / PVDF
Ball valve: PP / PVDF
Inlet safety seal: PVDF, PTFE, Viton®
Outlet safety seal: PVDF
Rinse connection socket: PVDF
Dimension Immersion depth: 71 to 207 mm
(2.8 to 8.15 inch)
Process temperature PA version: max. 80 °C (max. 176 °F)
Stainless steel pressure cylinder: max. 120 °C (248 °F)
Process pressure PA pressure cylinder: max. 6 bar (87 psi)
Stainless steel pressure cylinder: max. 10 bar (145 psi) at 40 °C (104 °F)
Connection Process connection DN50, ANSI 2"
Certificates, declarations and approvals Inspection certificate 3.1 acc. to EN 10204 on demand

The Cleanfit CPA474 retractable assembly is designed for applications requiring safe process isolation and for media that can corrode or contaminate stainless steel. It offers maximum operating convenience: sensors can be replaced, and the assembly even serviced, while the process is running. Optional electric or pneumatic control systems ensure automatic cleaning and calibration even under demanding process conditions.

 

Benefits

With stainless steel ball valve for safe and reliable process isolation even under harsh process conditions

Suitable for corrosive media: wetted parts made of high-performance polymers (PP, PVDF, PEEK)

Electrode cleaning and calibration without process interruption - saves maintenance time and costs

Automatic cleaning function extends the service life of the electrode

Various materials and process connections available for greater application flexibility

 

Application areas

The Cleanfit CPA474 is used for measurement in tanks and pipes:

 

Chemical industry

Wastewater / industrial water

Power plants

Waste incineration plants

For pressures up to 10 bar (stainless steel cylindrical tanks) or 6 bar (PA cylindrical tanks).

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

市政污水处理

市政污水处理污水处理厂 · 支架应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 支架应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 支架应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 支架应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对支架的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。