质量流量计 83F
Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Characteristic / Application | The universal and multivariable flowmeter for liquids and gases |
| Ambient temperature | -20...65°C (-4...+140°F) |
| Process temperature | -50...+350°C (-58...+662°F) |
| Process pressure | PN 16...100 Cl 150...600 JIS 10...63K |
| Wetted parts | 904L/1.4539 Alloy C-22/2.4602 |
| Output | 4...20mA Pulse/Frequency (10KHz, active/passive) Relays/Status |
| Certificates / Approvals | ATEX FM CSA TIIS |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | CE, C-tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, FDA |
Gas
| Measuring Principle | Coriolis |
| Product headline | The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, FDA |
Liquids
| Measuring Principle | Coriolis |
| Product headline | The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | CE, C-tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, FDA |
Steam
| Measuring Principle | Coriolis |
| Product headline | The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, FDA |
The Promass F series Coriolis flowmeter has a wide range of applications and has earned an excellent reputation for high-accuracy measurement under changing process conditions. In combination with the Promass 83 transmitter with touch control, four-line display and extended functions (such as filling, dosing, concentration measurement or advanced diagnostics), the Promass 83F mass flowmeter performs high-accuracy liquid and gas measurement.
Benefits
Modular design and operating concept for greater efficiency
Optional batching and concentration measurement software as extended functions
Diagnostics and data backup functions improve process quality
Integrated multivariable flow measurement
Balanced dual-tube measuring system design for excellent vibration resistance
Robust design, unaffected by external pipe forces
No inlet/outlet runs required, easy installation
Application
The Coriolis measuring principle is independent of the physical properties of the fluid, such as viscosity and density.
Extremely accurate measurement of liquid and gas flow, e.g. oils, lubricants, fuels, liquefied gases, solvents, foods and compressed gases (natural gas)
Fluid temperature up to +350 °C (662 °F)
Process pressure up to 100 bar (1450 psi)
Mass flow measurement up to 2200 t/h (80 850 lb/min)
Hazardous area approvals
ATEX, FM, CSA, TIIS
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Case Studies
市政污水处理污水处理厂 · 质量流量计应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 质量流量计应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 质量流量计应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 质量流量计应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。