质量流量计
Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Characteristic / Application | The universal and multivariable flowmeterfor liquids and gases |
| Ambient temperature | -20...+65°C (-4...+140°F) |
| Process temperature | -50...+350°C (-58...+662°F) |
| Process pressure | PN 16...100 Cl 150...600 JIS 10...63K |
| Wetted parts | 904L/1.4539 Alloy C-22 |
| Output | 4...20mA Pulse/Frequency Status |
| Certificates / Approvals | ATEX FM CSA TIIS |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Gas
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A,, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Liquids
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Steam
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
The Promass F series has earned an excellent reputation for its high-precision measurement and equipment robustness, with a wide range of applications. With the Promass 80 transmitter, it provides precise flow measurement of liquids and gases under changing, demanding process conditions.
Benefits
-
Modular device and operating concept for greater efficiency
-
Data backup improves process quality
-
Compact multivariable flow measuring instrument
-
Balanced two-tube measuring system design with good vibration resistance
-
Rugged construction, unaffected by external pipe forces
-
No inlet/outlet straight pipe runs required, easy installation
Application areas
The Coriolis mass flow measuring principle is independent of the physical properties of the fluid, such as viscosity and density.
-
Extremely precise measurement of liquids and gases such as oils, lubricants, fuels, liquefied gases, solvents, food products and compressed gases (natural gas)
-
Fluid temperature up to +350 °C (+662 °F)
-
Process pressure up to 100 bar (1450 psi)
-
Mass flow measurement up to 2200 t/h (80 850 lb/min)
Hazardous area approval
-
ATEX, FM, CSA, TIIS
-
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Case Studies
市政污水处理污水处理厂 · 质量流量计应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 质量流量计应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 质量流量计应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 质量流量计应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。