Technical Data
CompareORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Media with very low conductivity or a high proportion of organic solvents or alcohol: • Chemical industry • Organic chemicals • Power stations • Laboratory measurements |
| Characteristic | Digital ORP electrode for process engineering with ceramic junction and KCl liquid electrolyte |
| Measuring range | –1 500 to 1 500 mV |
| Measuring principle | Liquid-KCl filling and ceramic junction |
| Design | All shaft lengths with temperature sensor |
| Material | Sensor shaft: Glass to suit process ORP measuring element: Platinum Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft length: 120, 225, 360 and 425 mm (4.72, 8.86, 14.17 and 16.73 inch) |
| Process temperature | –15 to 135 °C (5 to 275 °F) |
| Process pressure | 0.8 to 11 bar (11.6 to 159.5 psi) (absolute) |
| Temperature sensor | NTC 30k |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2. |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
Field of application
Memosens CPS42E is the high performer for harsh chemical applications, media with low conductivity or considerable organic content. The sensor is designed for fast response especially in applications with fast-changing media. Thanks to Memosens 2.0 digital technology, CPS42E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Media with low conductivities or a high proportion of organic solvents or alcohols and fast changing media:
Chemical industry
Organic chemicals
Power plants, e.g. boiler feed water
Laboratory measurements
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Resistant to poisoning due to permanent refilling of KCl bridge electrolyte and separate reference lead
Perfectly suited for quickly changing media: Combination of liquid KCl electrolyte and ceramic junction enables fast response time
Applicable at very low conductivities (> 5 µS/cm) thanks to liquid KCl electrolyte
Suitable for cleaning in place (CIP) and sterilization in place (SIP)
Maximum process safety through non-contact inductive signal transmission
Reduced operating costs due to minimized process downtime and extended sensor lifetime
ORP / Redox
| Measuring Principle | Sensor ORP / Redox | |
| Application | Media with very low conductivity or a high proportion of organic solvents or alcohol: • Chemical industry • Organic chemicals • Power stations • Laboratory measurements |
|
| Characteristic | Digital ORP electrode for process engineering with ceramic junction and KCl liquid electrolyte | |
| Measuring range | –1 500 to 1 500 mV | |
| Measuring principle | Liquid-KCl filling and ceramic junction | |
| Design | All shaft lengths with temperature sensor | |
| Material | Sensor shaft: Glass to suit process ORP measuring element: Platinum Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
|
| Dimension | Diameter: 12 mm (0.47 inch) Shaft length: 120, 225, 360 and 425 mm (4.72, 8.86, 14.17 and 16.73 inch) |
|
| Process temperature | –15 to 135 °C (5 to 275 °F) | |
| Process pressure | 0.8 to 11 bar (11.6 to 159.5 psi) (absolute) | |
| Temperature sensor | NTC 30k | |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2. | |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology | |
| Ingress protection | IP68 | |
Case Studies
市政污水处理污水处理厂 · ORP应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · ORP应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · ORP应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · ORP应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。