Order Code:6I3BL4-BBDBAEAFAASAGA1ABGA2+AK
Name:t-mass I 300, 6I3BL4, 608mm 24"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval; Transmitter + Sensor | BB | ATEX+IECEx; Z0/1, Z21, Ex de, IIC/IIIC |
| 015 | Power Supply | D | DC 24V |
| 020 | Output; Input 1 | BA | 4-20mA HART |
| 021 | Output; Input 2 | E | Pulse/freq./switch output |
| 022 | Output; Input 3 | A | W/o; |
| 030 | Display; Operation | F | 4-line illum.; touch control |
| 040 | Housing | A | Alu, coated |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Sensor Version; Sensor; Insertion Tube | SA | Unidirectional; stainl. steel; stainl. steel |
| 070 | Process Connection | GA1 | G3/4", ISO 228/1, compression fitting |
| 075 | Seal | AB | PEEK, FKM, -40...+140oC |
| 080 | Flow Calibration | G | Factory calibration |
| 480 | Device Model | A2 | 2 |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is a 6I3B insertion thermal mass flowmeter, good long-term stability, compact transmitter for easy operation, with ATEX and IECEx approval, usable in Zone 0, Zone 1 and Zone 21, Ex de protection, 24 VDC supply, 4-20 mA HART plus pulse frequency and switch output, 4-line backlit display with light-sensitive keys, can be operated through the glass, aluminium housing with anti-corrosion coating, G3/4 compression fitting, PEEK and FKM seal rated -40 to 140 °C, suitable for gas metering in hazardous areas.