Order Code:93TA1-BBBEAG+D1
Name:Prosonic Flow 93T portable
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | P Sensor set DN15-DN65 1/2-2 1/2"/6MHz | B | -40...100oC/-40...212oF + installation set |
| 020 | P Sensor set DN50-DN300 2"-12"/2MHz | B | -40...80oC/-40...176oF + installation set |
| 030 | P Sensor Set DN100-DN4000 4"-160"/1MHz | B | -40...80oC/-40...176oF + installation set |
| 040 | Sensor Cable | E | 5m/15ft, PTFE, -40...170 oC/-40...338oF |
| 050 | Approval | A | Non-hazardous area |
| 060 | Operation language | G | CN = ZH+EN |
| 530 | Sound velocity sensor set | D1 | DN50-DN4000 2"-160" |
Configuration Explained
This is a 93TA1 economy ultrasonic flowmeter, data export via USB stick, no additional software needed, for non-hazardous areas, Chinese and English interface, with 5 m PTFE sensor cable, resistant to -40 to 170 °C, with DN15-65 mounting accessories, resistant to -40 to 100 °C, with DN50-300 mounting accessories, resistant to -40 to 80 °C, with DN100-4000 mounting accessories, resistant to -40 to 80 °C, with sound velocity sensor, suitable for in-line flow measurement in pipes up to DN4000.