CYP02E Digital maintenance tool

CYP02E Digital maintenance tool
Digital maintenance tool
Memocheck CYP02E is a service tool for fast and easy on-site checks of your measuring systems. The double plug-in head simulates two pre-defined sensor statuses. Memocheck is connected instead of the sensor and checks the complete measuring chain from cable coupling to the process control system. You can be sure that the measured values are transmitted error free.
Compare

Conductivity

Measuring Principle Conductive
Application Memocheck service tool for quick checks of measuring chains with Memosens technology

Disinfection

Measuring Principle Free chlorine
Application Memocheck service tool for quick checks of measuring chains with Memosens technology

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Memocheck service tool for quick checks of measuring chains with Memosens technology

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Memocheck service tool for quick checks of measuring chains with Memosens technology

pH

Measuring Principle Potentiometric
Application Memocheck service tool for quick checks of measuring chains with Memosens technology

The Memocheck CYP02E maintenance tool performs fast and convenient checks of the measuring system on-site. Its dual-plug structure can simultaneously simulate two preset sensor states. Connect the Memocheck instead of the sensor directly to check the entire measuring loop, from the cable connector to the process control system, ensuring error-free transmission of measured values.

Benefits
Fast and convenient on-site checks: the dual-plug structure simultaneously simulates two different sensor states, verifying and ensuring correct installation or commissioning of the measuring point.

  • Ensures measuring loop safety: checks the entire signal transmission path from the cable connector to the process control system.

  • Tamper-proof: modification of the simulated data is prevented.

  • Explosion-protection approval for use in hazardous areas.

Applications
The Memocheck simulates the pH value as well as a second parameter (e.g. pH, ORP, dissolved oxygen, conductivity or chlorine). It performs Memosens measuring system checks easily and reliably, suitable for the following processes:

  • Installation

  • Commissioning

  • Troubleshooting

  • The Memocheck meets the requirements for use in all industries.

 

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

 

Accessories/Spare parts

 

Source: Endress+Hauserpublic information from the website

All documents for this model
4 documents · click to expand
BA

Memocheck CYP02E Chinese

Rev. 0119 12 pages
Preview
BA

Memocheck CYP02E English

Rev. 0119 12 pages
Preview
TI

Memocheck CYP02E Chinese

Rev. 0121 8 pages
Preview
TI

Memocheck CYP02E English

Rev. 0121 8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gas Analysis — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Gas Analysis properly configured on the existing plant, with the aim of continuous analysis of target components in flue or process gas.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Gas Analysis configuration has to involve choosing the analysis principle by range, background gas and conditioning.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing the analysis principle by range, background gas and conditioning, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is optimised combustion, cutting both fuel use and emissions, and the readings are now used for process tuning.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · humidity level — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on humidity level and the core task is measuring gas humidity or dew point for drying and process control.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So humidity level cannot be specified generically — it calls for choosing sensor type by dew-point range, pressure and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing sensor type by dew-point range, pressure and corrosivity, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is controlled dew point, improving both product quality and energy use.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.