Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM411-BJ2AF1J1DB1D1X30Q1A000A3C2C22CA1A1

TM411-BJ2AF1J1DB1D1X30Q1A000A3C2C22CA1A1
Product family: iTHERM ModuLine TM411

Hygienic modular RTD thermometer

Endress+Hauser TM411-BJ2AF1J1DB1D1X30Q1A000A3C2C22CA1A1
iTHERM ModuLine TM411;Approval ATEX II1/2G Ex ia IIC T6;Thermowell Detachable process connection;Material Wetted Parts 316L;Process Connection Type Male thread ISO 228 (for Liquiphant adapter);Process

Order Code:TM411-BJ2AF1J1DB1D1X30Q1A000A3C2C22CA1A1

Name:iTHERM ModuLine TM411

Configuration

CodeNameOrderSpecification
010ApprovalBJATEX II1/2G Ex ia IIC T6
020Thermowell2Detachable process connection
030Material Wetted PartsA316L
040Process Connection TypeF1Male thread ISO 228 (for Liquiphant adapter)
050Process Connection SizeJ1G3/4 male thread ISO 228 for FTL20/31/33 adapter, 3-A, ASME BPE
060Thermowell External Diameter D1D12.7mm
070Tip Shape; External Diam. D2; Length ReB1Straight (D1=D2)
080Surface Wetted PartsD1Ra<=0.76um (D1=12.7mm)
090Immersion Length UX30..... mm (9/12.7mm TW)
100Neck/Thermowell ConnectionQ1iTHERM QuickNeck neck separable - quick release
110Neck Length EA0Not needed
120Lagging Length T00Predefined (not selectable)
130Sensor Type; Measuring RangeA31x Pt100 TF, iTHERM QuickSens fast response; -50...+200oC
140Insert Design; Diam. d; Sheath MaterialC24-wire MI-cable; 6mm; 316L
150Accuracy acc. IEC60751C2Class AA (iTHERM QuickSens, 6mm)
160Electrical Connection2C4-20mA, 1-channel TMT71, head transmitter DIN B
170Terminal Head;Material;Protection ClassA1TA30A; Alu; IP66/68, NEMA Type 4X
180Neck Connection Terminal HeadA1M24x1.5 female thread
7 models · click to collapse