CA610 Fluoride Analyzer with Reagents
HACH 5740001
The CA610 Fluoride Analyzer delivers accurate, real-time fluoride monitoring for municipal water treatment. With advanced ion-selective electrode (ISE) technology, it provides dependable results and h

产品概述

The CA610 Fluoride Analyzer delivers accurate, real-time fluoride monitoring for municipal water treatment. With advanced ion-selective electrode (ISE) technology, it provides dependable results and helps maintain water quality compliance with less effort.

• Continuous Monitoring: Real-time fluoride data for precise control and easy regulatory reporting.

• Patented ISE Technology: Durable lanthanum crystal tip ensures reliable, consistent readings.

• Efficient Operation: Low reagent use and straightforward maintenance minimize downtime and costs.

• Automated Calibration: Simplifies routine checks for uninterrupted performance.

The CA610 Fluoride Analyzer simplifies fluoride analysis, making it essential for monitoring water quality. With advanced technology, it provides precise, reliable results to help ensure clean, safe water for communities and industries. Meeting strict regulatory standards, the CA610 supports water safety with efficiency and confidence.

主要特点

  • Reliable, Full-time Fluoride Monitoring:The CA610 Fluoride Analyzer uses advanced ion-selective electrode (ISE) technology for continuous monitoring of fluoride concentration in drinking water effluent. Accuracy is ensured with precise control of temperature, ionic strength, and pH. Interferences that can bias measurements are virtually eliminated with this electrode.
  • Patented Electrode Design with Replaceable Tip:The proven ISE technology of the electrode is enhanced by a patented* design and manufacturing process. The lanthanum crystal at the tip of the probe is molded into a one-piece, monolithic tip that is threaded for easy removal. This prevents errors and premature failures. Electrodes are equipped with BNC connectors so that they can be independently checked with laboratory electrochemical meters.
  • Cost Effective Operation:The electrode of the CA610 analyzer is made with a molded fluoride crystal tip. The working life of the electrode is approximately one year. The specially designed tip of the electrode should be replaced every six months. Reagent consumption is very low and maintenance is simple.
  • Method of Analysis:The ISE system of the CA610 analyzer includes a reference pH electrode and a working electrode. Three reagents are used: Total Ionic Strength Adjustment Buffer (TISAB) solution and two fluoride standards. The TISAB is used for the following purposes. The Ionic strength adjustment lets the electrode respond to concentration instead of activity. The pH control ensures fluoride is present in its ionic state. The Weak complexes formed by certain metals (for example, aluminum) are broken up by TISAB and chelates potential interferents for accurate fluoride measurement.
  • Automatic Calibration:Two calibration standards are fully enclosed in the CA610 analyzer's case. The instrument performs a 2-point calibration at 0.5 and 5.0 mg/L fluoride at user-selected time intervals. Automatic calibration intervals can be set for 1 day to 1 month. Readings and calculations of the most recent calibration is stored in the instrument.

技术参数

参数名称说明
Accuracy± 10 % or ±0.10 mg/L whichever is greater
Air Purge0.1 cfm at 20 psig
AlarmTwo alarms, selectable for sample concentration, system warning or system shutdown. Each alarm equipped with an SPDT relay with contacts rated for 5 A resisitive load at 230 Vac.
Calibration Method5.0 mg/L fluoride standards
Compliance CertificationsCE approved, ETL listed to UL 1262, ETL certified to CSA 22.2 No. 142
Cycle Time4.2 min
Dimensions (H x W x D)475 mm x 341 mm x 179 mm
DisplayLCD, 3 to 1/2 -digit measurement readout and six-character alphanumeric scrolling text line
Drain Fitting1/2-inch ID flexible hose
Inlet1/4-inch OD polyethylene tubing, quick-disconnect fitting
Inlet Pressure1 - 10 psig (use sample restriction device to reduce higher pressure samples)
Lower Limit of Detection (LOD)0.10 mg/L 0.10 ppm
MountingWall mount
Operating Humidity90% at 40 °C (104 °F)
Operating Temperature Range5 - 40 °C (41 - 104 °F)
Power Requirements (Amps)2.5 A
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 115/230 V AC
Power Supplyselectable, 90 VA max. ,
Range0.1 - 10.0 mg/L Fluoride
Recorder OutputsAn isolated output of the recorder, from 4 to 20 mA (can be set from 0 to 20 mA)
Sample Flow Rate200 - 500 mL/min
Sample Temperature5 - 40 °C (41 - 104 °F)
Storage Conditions-40 to 60 °C (-40 to 140°F) without reagents
Warranty12 months
Weight11.3 kg (25 lbs)
What's included?CA610 Fluoride analyzer, one-month supply of reagents, installation kit, annual maintenance kit, Hach user manual

应用领域

Municipal Water