Product family:
LCP pH Sensors 2 wire
Differential 1.5" pH sensor, LCP, 2-wire, 3 m cableDiscontinued
Regenerateable Encapsulated LCP or PPS Differential pH and ORP Sensors-ideal for aggressive applications.
产品概述
Regenerateable Encapsulated LCP or PPS Differential pH and ORP Sensors-ideal for aggressive applications.
LCP (Liquid Crystal Polymer), Convertible Mounting Style, 3m Analog Cable, 2-Wire with Built-In Transmitter, General Purpose Glass pH Electrode
主要特点
- Exceptional Performance with the Differential Electrode Measurement Technique:This field-proven technique uses three electrodes instead of the two normally used in conventional pH sensors. Process and reference electrodes measure the pH differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
- Lower Maintenance Needs with the Replaceable Salt Bridge:The salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
- Built-in Preamp or Two-Wire Transmitter:The built-in preamp produces a strong signal, enabling you to locate the analyzer up to 3000 ft. (914 m) from the sensor. An optional built-in two-wire transmitter is available for applications requiring a 4-20 mA sensor signal. This option requires that the indicating instrument of the measuring system be capable of providing 24 VDC to power the sensor, and have adjustment means to calibrate for zero offset and span.
- Versatile Mounting Styles:1.5 inch NPT threads are provided on both ends of the convertible mounting style sensor for either mounting into a pipe tee or attaching to the end of a pipe for immersion. The convertible style enables you to consolidate inventory, and thereby reduce associated costs. A union-mount style sensor and mounting tee are also available to conveniently install and remove the sensor for in-line service.
- 3,000 ft. (914 m) transmission distance:
- Also available with flat glass electrodes:
技术参数
| 参数名称 | 说明 |
|---|---|
| Body material | LCP |
| Cable Length | 3 m 10 ' 2-conductor (twisted pair) |
| Diameter | 55 mm |
| Drift | 0.03 pH per 24 hours, non-cumulative |
| Electrode Material | Glass |
| Flow | Max. 3 m/s |
| Junction | PVDF Junction |
| Length | 180 mm |
| Material | Ground Electrode: Titanium or Hastalloy C |
| Measuring Range ORP | ±2000 mV |
| Measuring Range pH | 0 - 14 pH |
| Mounting | Convertible |
| Pressure Range | Max. 10.7 bar sensor only (pressure range of mounting hardware to be checked separately) |
| Sensitivity | < 0.5 mV |
| Sensitivity | < 0.005 pH |
| Sensor Thread | 1.5" NPT at both ends |
| Special Notes | pH sensor with built-in two-wire transmitter providing 4-20 mA output |
| Temperature Range | -5 - 95 °C (23 - 203 °F) |
| Temperature Sensor | NTC 300 Ω thermistor for automatic temperature compensation and analyzer temperature readout |
| Warranty | 12 months |
| Weight | 0.6 kg |
| What's included? | Includes: sensor with 10 ft cable and manual |
应用领域
Membrane Protection · Nutrient Monitoring · Nutrient Monitoring · Secondary Treatment · Secondary Treatment · Ultrapure Water
同系列其他配置
| 型号 | |
|---|---|
| 6458P0 | pH Sensor, Union-mount, LCP (Liquid Crystal Polymer) Body Material, 2- |
| 6428P010010000N | pH Encapsulated Sensor, LCP Body, 2 Wire, Convertible, FKM/FPM Seals, |
| 6428P020 | pH Encapsulated Sensor, LCP Body, 2 Wire, Convertible, FKM/FPM Seals, |
| 6428P030 | pH Encapsulated Sensor, LCP Body, 2 Wire, Convertible, FKM/FPM Seals, |
| 6428P050 | pH Encapsulated Sensor, LCP Body, 2 Wire, Convertible, FKM/FPM Seals, |
| 6428P025 | pH Encapsulated Sensor, LCP Body, 2 Wire, Convertible, FKM/FPM Seals, |
资料下载
- Complete Water Analysis for the UPSTREAM OIL & GAS INDUSTRY
- Introduction to Hach Services
- Complete Water Analysis Solutions for the Food Industry
- Soluciones completas de análisis de agua INDUSTRIA ALIMENTARIA
- Encapsulated Differential pH and ORP Sensors
- Được đóng kín Cảm biến pH vi sai và cảm biến ORP
- User Instructions: sc Sensors Class 1, Division 2 Safety Precautions
- User Manual : pHD Analog Differential pH/ORP Sensors
Related Products
HACHRadiometer Analytical PHC3105-9 Combination pH Electrode (epoxy body, gel electrolyte, screw cap)
View →
HACHRadiometer Analytical PHC3031-9 Combination pH Electrode for Penetration Applications (glass body, Ag/AgCl ref., screw cap)
View →
A
HACHRadiometer Analytical PHC4006-9 Combination Calomel pH Electrode (l=158 mm, d=6.5 mm, glass body, screw cap)
View →
A
HACHRadiometer Analytical PHG200-8 Glass pH Electrode for Microsamples (d=4 mm, BNC)
View →
HACHRadiometer Analytical PHG201-8 Glass pH Electrode (d=7.5 mm, BNC)
View →
HACHpH Electrode Storage Solution, 500 mL
View →
HACHRadiometer Analytical PHC2601-8 Combination Red-Rod pH Electrode (sleeve junction, glass body, BNC)
View →
A
HACHRadiometer Analytical PHC2401-7 Combination Red-Rod pH Electrode (glass body, type 7 plug)
View →