1735 TRO Analyzer, ATEX Certified with power supply and RS 485Discontinued
HACH 9360010
Provides a wide range of TRO measurement for shipboard applications.

产品概述

Provides a wide range of TRO measurement for shipboard applications.

The Hach 1735 TRO (Total Residual Oxidant) Analyzer is ATEX Zone 1 Intrinsically Safe (IS) certified for use in hazardous environments. It meets all relevant IMO standards including tilt and vibration, and is built to withstand shipboard conditions. Under typical use this analyzer will operate unattended for at least 60 days. Five minutes of routine maintenance is required every two months including reagent replacement. The 1735 requires no calibration or special tools, and is able to operate in spaces where ambient temperatures can reach as high as 50°C.

Utilizing the proven DPD method of testing, which is not affected by changes in sample pH, temperature, pressure or flow, the 1735 provides you with extremely accurate results. A 75 second cycle time provides fast response to changes in sample conditions. The 1735 analyzer also provides a wide TRO measurement range of 0 to 10ppm.

The Hach 1735 TRO Analyzer was designed with Hach’s expertise in water quality to provide reliable TRO measurements in shipboard applications for ballast water treatment systems.

主要特点

  • Intrinsically Safe (IS) Certified:The Hach 1735 TRO Analyzer is an ATEX Zone 1 intrinsically safe certified analyzer for use in hazardous, or potentially hazardous environments. This design allows the user to interact and perform maintenance with ease. In addition, it does not require heavy enclosures or additional resources, such as purge gas.
  • Superior Reagent Life:Suitable for high temperature environments such as engine room installations on ships where the ambient temperature can rise as high as 50 °C. Hach reagents can provide accurate measurements for up to 70 days at these high temperatures. The extended reagent life minimizes interaction with the instrument and the operating costs.
  • Accurate Results:The Hach 1735 TRO Analyzer uses colorimetric DPD chemistry to monitor water online for TRO concentration. This is the same method as used in the Hach CL17 Chlorine Analyzer, an industry leader for 35 years. The accuracy of this analysis method is not affected by changes in sample pH, temperature, chlorine concentration, salinity (within the specified measurement ranges), pressure or flow, thus offering more accuracy than other available methods.
  • Minimal Maintenance:The Hach 1735 TRO Analyzer is designed to require minimum maintenance. Under typical use*, the Hach 1735 TRO Analyzer will operate unattended for 70 days. Less than 5 minutes of routine maintenance, including reagent changes, is required every 2 months. No calibration is needed, and no special tools are required. * 24 hours operation per week
  • Marine Application Ready:To measure total residual oxidant on vessels, the hach 1735 TRO Analyzer is built to withstand harsh shipboard conditions. It meetsIMO standards for tilt and vibration, and is protected by an IP64 rated enclosure which prevents corrosion caused by seawater.

技术参数

参数名称说明
Accuracy± 5 % of reading or ±0.035 mg/L (ppm), whichever is greater, from 0 - 6 mg/L (ppm)
Accuracy 2± 10 % of reading from 6.0 - 10 mg/L (ppm)
AlarmOn screen display only
Cycle Time75 seconds per measurement
Dimensions (H x W x D)380 mm x 336.2 mm x 203 mm
DisplayGraphic dot matrix LCD with LED backlighting, transreflective
Drain Fitting3/8 in. FNPT gravity drain
Enclosure ConstructionPowder coated steel
Enclosure RatingIP64
Flow Rate125 mL/min
Inlet Pressure4 - 6 psi
Manual LanguagesEnglish, German
Mounting ConfigurationsWall Mount
Operating HumidityMax = 90 % at 50°C, non-condensing
Operating Temperature Range-5 - 50 °C
Outputs4 to 20 mA. 4-wire configuration with common-referenced current sink Remote Interface:RS485 Modbus RTU
Power Requirements (Voltage)12 VDC
Range0 - 10 mg/L (ppm) as Chlorine† †The measured TRO concentration can be expressed as Bromine by choosing the option in the instrument menu.
RegulatoryCE marked Inclination: IEC-60092-504 Vibration: IEC-60068-2-6 ATEX version only: Ex II 2G Ex ib IIC T5 Gc (5°C ≤ Tamb ≤ 50°C)
Sample Flow Rate125 mL/min
Sample Inlet Connection1/4 in. FNPT sample line
Sample Pressure4 - 6 psi
Sample RequirementsSample must be filtered to 35 micron or less
Sample Temperature5 - 40°C (41 - 104°F)
Storage Conditions-20 °C to 60 °C