AS950 All Weather Refrigerated Sampler, 2 Sensor Port Options, 115 V, Discrete (4x) 10 L PE Bottle Kit
HACH ASA.CSXX1X31XX
The AS950 All-Weather Refrigerated Sampler simplifies sampling with a large, full-color display for intuitive, single-screen programming, USB upload and download capabilities and the ability to copy p

产品概述

Sampling has never been this easy.

The AS950 All-Weather Refrigerated Sampler simplifies sampling with a large, full-color display for intuitive, single-screen programming, USB upload and download capabilities and the ability to copy programs sampler to sampler to save time on tedious programing, and an error alert and status screen to eliminate uncertainty and simplify troubleshooting. The custom-designed air-sensing thermostat controls temperature in accordance with USEPA and international guidelines, preserving samples regardless of outside temperatures and conditions.

主要特点

  • Easiest and Most Intuitive Operation:The large full color display and intuitive programming give you access to all your programmable criteria on a single screen - eliminating scrolling through menus and supporting error-free operation.
  • Most Convenient Data Transfer and Programming Available:The AS950 is the only sampler that utilizes a USB drive to upload and download data and copy programs from one sampler to another.
  • Confidence in Your Sampling Process:The program status screen instantly communicates alarms, missed samples and program progress for quick and easy troubleshooting.
  • Resists Corrosion:The All-Weather Refrigerated (AWR) sampler base is designed to endure humid and highly corrosive environments, minimizing damage caused by corrosive gases, rodents, and standing water to guarantee environmental integrity.
  • Accurate and Consistent Sample Preservations:The custom-designed air-sensing thermostat controls temperature in accordance with USEPA and international guidelines, preserving samples regardless of outside temperatures and conditions.
  • Easy Maintenance at Low Cost:Spring-mounted rollers provide long tubing life keepign maintenance costs low. The desiccant and pump tubing can easily be accessed; the replacement is possible without any tools. The rugged see-through pump cover is made for a quick visual inspection.

技术参数

参数名称说明
AlarmConfigurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Automatic ShutdownMultiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected) Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Base TypeAll Weather
Body materialIP24, low-density Polyethylene with UV inhibitor
CertificationsCE, UL
Communication CapabilitiesUSB and optional RS485 (Modbus)
Cooling systemTop mounted compressor and fan-forced air cooled condenser; 11/5 HP 115 VAC: 115 °C (239 °F) thermal overload protector, 7.1 locked rotor amps; 230 VAC: 120 °C (248 °F) thermal overload protector, 7.6 A peak start current; 3-sided wraparound plate type evaporator; Rigid foam insulation: 3 in. (7.6cm) sides, 5 in. (12.7cm) top, 6 in. (15.2cm) bottom; Lockable lid to prevent tampering with programming; Recovery Time: Sampler temperature recovers to 4°C within 5 minutes after door has been held open for one minute in 24°C (75°F) ambient environment while in an active cooling cycle; Pull Down Time: from 24°C (75°F) to 4°C (39°F), 20 minutes; Temperature Control: 4 (±0.8) °C (39 (±1.5) °F)
DiagnosticsView event and alarm logs as well as maintenance diagnostics
Dimensions76 x 81 x 130 cm (30 x 32 x 51 in.)
Dimensions (H x W x D)1300 mm x 760 mm x 810 mm
Display1/4 VGA, Color; self-prompting/menu-driven program
Factory Installed OptionsTWO SENSOR PORTS Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors |RAIN/RS485 PORT Accepts Hach Rain Gauge (not included) or can be used as RS485 communications |NON-CONTACT LIQUID DETECT Sample volume accuracy for applications that require complete tubing replacement | Please contact your Hach sales representative for details.
Housing MaterialPC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
InputsOne 0/4-20 mA input for flow pacing
IntakeStrainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications Purge: Air purged automatically before and after each sample; duration automatically compensates for varying intake line lengths Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Internal Clock±1 second per day at 25 °C (77 °F)
Lock FunctionAccess code protection prevents tampering
Manual SamplingInitiates a sample collection independent of program in progress
MemorySample history: 4000 records; Data log: 325,000 records; Event log: 2000 records
Operating ModeContinuous or non-continuous
Pollution Degree2
Power Requirements (Hz)50 - 60 Hz
Power Requirements (Voltage)115 V
Probes includedNo
ProgramsDual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
Pump flow rate4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical
Rain Gauge EnabledNo
Refrigeration Components and PlumbingCorrosion protected with conformal all exposed copper tubing is insulated to avoid sweating and condensation
Sample Container4 - 2.5 Gallon
Sample IntervalSelect. in single increments from 1 to 9,999 flow pulses or 1 to 9,999 mins in one minute increments
Sample PumpHigh-speed peristaltic, dual roller, with 0.95 ID x 0.16 OD cm (3/8 ID x 5/8-in. OD) pump tube; Pump body IP37, Polycarbonate cover
Sample Transport Velocity0.9 m/s with 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, 21 °C and 1524 m elevation
Sample TriggerWhen equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
Sample Volume AccuracyTypical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sample Volume RepeatabilityTypical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sampling ModePacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event Distrib.: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
Sensor Ports2
Status MessagesCommunicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Suction Hose Outer Diameter1/4" and 3/8" ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
TubingPump tubing: 9.5 mm ID x 15.9 mm OD Silicone Intake tubing: 1.0 - 4.75 m minimum length, 1/4" or 3/8" ID Vinyl or 3/8" ID PTFE-lined Polyethylene with protective outer cover (black or clear)
User InterfaceMembrane switch keypad with 2 multiple function soft keys
User Interface LanguagesChinese, English, French, German, Italian, Spanish, Portuguese
Vertical Lift8.5 m using 8.8 m maximum of 3/8-in. vinyl intake tube at sea level at 20 to 25 °C
Warranty12 months
Weight86 kg
What's included?1 ea. AS950 controller with sensor ports on 115V All Weather base 1 ea. Bottle kit (AW040030) includes 4- 2.5 gallon poly bottles w/caps (2315) and distributor arm (8843) 1 ea. 25' vinyl intake tubing (920) 1 ea. strainer (926)