Product family:
Contacting conductivity sensor
Contacting Conductivity Digital Sensor, 0.50 Cell Constant, Compression Fitting Style
Ultimate accuracy from ultra-pure to high conductivity applications.
产品概述
Ultimate accuracy from ultra-pure to high conductivity applications.
Nominal Cell Constant (K) = 0.5, 3/4 inch NPT PVDF Compression Fitting, 7m (23 ft) Digital Cable, Titanium Electrode
主要特点
- High Performance Design:These enhanced performance sensors are manufactured to exacting tolerances using high quality, rugged materials for demanding applications including ultra-pure water, clean-in-place (CIP), and boiler/condensate monitoring. Each sensor is tested to determine its unique, absolute four-digit cell constant. Also, each sensor has a Pt 1000 RTD temperature element built into its tip for exceptionally fast response to changes in temperature with ±0.1ºC accuracy.
- Resistivity and Conductivity Measurement Capability:These enhanced performance sensors measure from theoretically pure water (0.057 µS/cm or 18.2 MΩ) up to 200,000 µS/cm. Hach’s sc Digital Controllers accept multiple digital sensor inputs, and can be user-set to measure conductivity, resistivity,TDS, salinity, or one of six calculated measurements.
- Versatile Mounting Styles:Compression fitting sensors feature titanium electrodes and a compression fitting for universal installation with up to 4 inches (102 mm) insertion depth. The 1/2-inch or 3/4-inch male NPT compression fittings are offered in PVDF or 316 stainless steel. A longer version of this sensor is available for use with a 316 stainless steel ball valve hardware assembly to insert/retract the sensor from the process without stopping the flow. The longer version can also be used for insertion through a compression fitting. Maximum insertion depth is 7 inches (178 mm).
- Full Featured “Plug and Play” with Digital SC Controller:There are no complicated wiring or set up procedures with any Hach SC controller. Just plug in any combination of Hach digital sensors and it's ready to use—it’s “plug and play.”
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ± 2 % of reading above 200 µS/cm |
| Cable Length | 6 m |
| Cable Length | Standard Probe Cable Length (integral)Digital Probe: 7 m (23 ft.) |
| Cell Constant k | 0.5 cm-1 |
| Digital Gateway | Integral Digital Gateway |
| Electrode Material | Titanium |
| Flow | 0 - 3 m/s (0–10 ft./s), maximum, fully immersed |
| Installation Kit | 3/4" NPT |
| Installation Requirement | PVDF |
| Installation style | Compression |
| Operating Temperature Range | -20 - 200 °C |
| Pressure Range | 0 - 300 psi (20.7 BAR) |
| Range | 0 - 1000 µS/cm |
| Repeatability | ± 0.5 of reading |
| Response Time | 90 % of reading within 30 seconds of step change |
| Sensitivity | ± .05 % of reading |
| Sensor Cable | Digital: PUR (polyethylene) 5-conductor, shielded, rated to 150°C (302°F) |
| Sensor Type | Digital |
| Temperature Compensation | Temperature Compensator: Pt 1000 RTD |
| Temperature Compensation | Temperature Compensator: Pt 1000 RTD |
| Temperature Measurement | -20 - 200 °C (-4 - 392°F) |
| Transmission Distance | 100 m (328 ft.), maximum |
| Transmission Distance | 1000 m (3280 ft.), maximum when used with a termination box |
| Warranty | 12 months |
| What's included? | Includes: sensor with 23 ft cable and manual |
应用领域
Membrane Protection · Nutrient Monitoring · Nutrient Monitoring · Secondary Treatment · Secondary Treatment · Ultrapure Water
同系列其他配置
| 型号 | |
|---|---|
| D3422D3 | Digital Contacting Conductivity Sensor, Compression Fitting Style, Cel |
| D3422E3 | Contacting Conductivity Digital Sensor, Compression Style, 10 Cell Con |
| D3433B8 | PPS Body General Purpose Digital Contacting Conductivity Sensor for lo |
| D3444B8 | Stainless Steel Digital Contacting Conductivity Sensor for Low Conduct |
| D3444D8 | Digital Stainless Steel Digital Contacting Conductivity Sensor for Hig |
| D3422A2 | Digital Contacting Conductivity Sensor for low conductivity (k=0.05) w |
| D3422C3 | Digital Contacting Conductivity Sensor, Compression Fitting Style, Cel |
| D3455A6 | Digital Sanitary (CIP) Contacting Conductivity Sensor for Low Conducti |
| D3455C7 | Digital Sanitary Flange Style Sensor, Stainless Steel Electrode, 1.0 C |
| D3422A1 | Contacting Conductivity Digital Sensor, 0.05 Cell Constant, Compressio |
| D3433E8 | Digital Contacting Conductivity Sensor, General Purpose, PPS Body, Cel |
| D3455E7 | Sanitary Flange-Style Conductivity Sensor, Cell Constant 10.0, 2 inch |
资料下载
- Complete Water Analysis for the UPSTREAM OIL & GAS INDUSTRY
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Complete Water Analysis Solutions for the Food Industry
- Soluciones completas de análisis de agua INDUSTRIA ALIMENTARIA
- Contacting Conductivity/Resistivity Sensors
- 3400 sc Conductivity CSI Specification
Related Products
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
View →
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
View →
HACHConductivity Solution, 1000-2000 µS/cm, 1 L
View →
HACHConductivity Solution, 2000-150,000 µS/cm, 1 L
View →
HACHConductivity Solution, 200,000-300,000 µS/cm, 1 L
View →
HACHConductivity Solution, 300,000-800,000 µS/cm, 1 L
View →
HACHCDW97-K10, Conductivity probe for salinity and brackish water
View →
A
HACHSolution, Conductivity Assembly
View →