产品概述
Total Package analyzer for Oxygen & Carbon Dioxide Measurements
The Orbisphere 6110 boasts the latest technology in final package analysis for measurements of Total Package Oxygen, Headspace Oxygen and Dissolved Oxygen; as well as dissolved Carbon Dioxide and Headspace Volume. It has been designed to meet the practical needs of both lab and at-line environments. The high-quality touch-screen facilitates measurement customisation on all types and sizes of cans or bottles, as well as providing critical information on the health of the instrument. Utilisation of this instrument has been proven to provide critical quality information of the final package, increasing process control and beverage quality. A Class 1 LASER is installed in this instrument. Exposure to the beam of a Class 1 LASER will not result in eye injury. Intrabeam viewing of Class 1 laser products which emit visible radiant energy may still produce dazzling visual effects, particularly in low ambient light.
主要特点
- Fast, Effective Operation:The 6110 delivers repeatable analysis with minimal operator intervention. The package positioning aid with laser crosshairs confirms optimal placement and the intuitive touch-screen interface ensures product sampling is completed quickly, easily, and consistently for both line operators and lab personnel. There is no sample preparation necessary for total package and head space oxygen analysis.
- Reliable and Flexible:The 6110 Total Package analyzer operates on all types of cans and bottles due to its unique gas extraction and piercing system, resulting in reliable analysis with no container leakages. The CO2 analysis measurement provides accurate results at any temperature, without having to warm the sample. The 6110 can also compensate CO2 results for any package Nitrogen content – a perfect choice for analysis directly at the filler.
- Gas Phase Measurement:The Hach Orbisphere 6110 analyzes beverages without removing any product from its container. The measurement takes place in the gas phase, so there is no direct liquid contact with the 6110’s sensing technology or sampling path. This reduces maintenance by eliminating hassles such as bleaching tubing and replacing valves to prevent fouling.
- Maximize the Uptime of your 6110 Total Package analyzer:Our expert service team works in partnership with you to provide professional start-up and commissioning and regular maintenance for your 6110 Total Package analyzer to ensure it is in the optimal condition. Please speak with your local Hach representative for service offerings in your region.
技术参数
| 参数名称 | 说明 |
|---|---|
| Communication Capabilities | 1x Ethernet, 1x USB-A |
| Compliance Certifications | European directives: Low voltage 2006/95/EC; EMC 2004/108/EC Electromagnetic compatibility standards: EN61326 Safety standard: IEC/UL/CSA 61010-1 Safety of Laser products: IEC/UL/CSA 60825-1 |
| Dimensions (H x W x D) | 942 mm x 540 mm x 537 mm |
| Display Type | Digital TFT VGA (640 x 480) colour touch screen |
| Enclosure Rating | IP20 |
| Installation Requirement | Power requirements: 100/240 VAC, 50/60 Hz Purge gas: CO2 with purity >99.9% at 6 to 7 bar abs (87 to 102 psi) |
| Laser Class | A Class 1 LASER is installed in this instrument. Exposure to the beam of a Class 1 LASER will not result in eye injury. Intrabeam viewing of Class 1 laser products which emit visible radiant energy may still produce dazzling visual effects, particularly in low ambient light. |
| Operating Conditions | Package temperature: -2 - 30 °C (28 - 86 °F) Package pressure: 1.4 - 6.8 bar (20 - 73 psi) Ambient temperature: 0 - 40 °C (32 - 104 °F) |
| Operating System | Windows® CE 4.2 |
| Package Type | Closure types: metallic, PET Package height: min. 90 mm (3.54 in.) max. 340 mm (13.39 in.) Package volume: min. 150 mL |
| Power Consumption | 250 VA maximum |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100/240 VAC |
| Range | O2: 1 ppb - 12 ppm CO2: 0.75 - 5 v/v or 1.5 - 10 g/kg |
| Repeatability | TPO: ±5 µg/L / ±10%, whichever is greater CO2: ±0.05 v/v or 0.10 g/kg ±2 %, whichever is greater, measured on equilibrated packages at 10 - 25 °C |
| Typical Analysis Time | Approximately 4 minutes |
| Units | O2 Concentration: ppb, ppm CO2 Concentration: v/v, g/kg, g/L %W Total Package Quantities: mg, mL, mg/L,mL/L, µg/L Pressure: bar, mbar, psi Temperature: °F, °C, K |
| Warranty | 12 months |
| Weight | 55 kg |
| What's included? | Orbisphere 6110 Total Package Analyzer (sensors pre-installed) with Installation Kit, User Manual. See user manual on downloads tab for installation kit components. |
资料下载
- Brewing and Beverage Industry : Air Injection in Cans
- O₂ Fingerprinting in Pasteurised Beverage Products Using Headspace Gas Analysis
- Influence of Oxygen on Beer Foam Stability — Monitoring with Hach Analytical Solutions
- Reference Standard for TPO Analytical Methods
- Criterios De referencia Para Los Métodos De Análisis Del Oxígeno Total Del Envase
- Quality Control In the Brewery: Innovative technology for gas analysis in beer packages
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
Related Products
Replacement Protector for Clark DO sensor
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
HACHOrbisphere 510 Controller O₂ (EC), CO₂ (TC), Wall Mount, 100-240 VAC, 0/4-20mA, Ext. Press.
HACHCarbon dioxide, dissolved oxygen, and pH test kit, model CA-10WR
HACHField Service Partnership, 3100 LDO, 1 Service/Year
HACHPocket Dissolved Oxygen (DO) Meter
HACHLuminescent Dissolved Oxygen flow cell assembly
HACH