Product family:
Digital Differential ORP Sensors, Non-Hazardous Environment
Digital ORP Sensor, PPS, Convertible, Non-Hazardous EnvironmentDiscontinued
The smart choice for accurate and reliable online process ORP measurement
产品概述
The smart choice for accurate and reliable online process ORP measurement
Specialty Online Process ORP Sensor with Integrated Digital Electronics for "Plug and Play" with Hach sc Digital Controllers - Gold ORP Electrode, PPS Housing, Convertible Mount, 10m Cable
主要特点
- Exceptional Performance with the Differential Electrode Measurement Technique:This field-proven technique uses three electrodes instead of the two normally used in conventional ORP sensors. Process and reference electrodes measure the ORP differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
- Lower Maintenance Needs with the Double Junction Salt Bridge:The double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
- Extended Working Life with the Replaceable Salt Bridge/Protector:The unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.
- Reliability with Built-in Encapsulated Preamp:Encapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analog sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyzer.
- Patented Technology:The former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD™ sensor series (U.S. Patent Number 6395158B1, dated May 28, 2002) takes this field-proven technology to a new level.
- Versatile Mounting Styles:Sensors are available in four mounting styles—convertible, insertion, immersion, and sanitary
技术参数
| 参数名称 | 说明 |
|---|---|
| Body material | PPS |
| Body Material | PPS |
| Cable Connection | Digital |
| Cable Length | 10 m (33 ft) |
| Cable Length | 10 m |
| Compliance | For non-hazardous and non-maritime applications only |
| Electrode Material | Gold |
| Electrode Type | Specialty - Gold |
| Flow | 3 m (10 ft.) per second, maximum |
| Mounting | Convertible |
| Operating Temperature Range | -5 - 70 °C (23 - 158 °F) pHD and ORP Before initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers. Please Note: When the sensor is placed into the application sample, if that sample is more than 10-°C (18-°F) different than the previous temperature/pH calibration, then it is recommended to recalibrate the temperature while the sensor is in the sample to maintain the ±0.5-°C (±0.9-°F) temperature accuracy specification. |
| Range | -1500 to +1500 mV ORP |
| Sensitivity | ± 0.5 mV |
| Sensor Cable | Integral 4 conductor cable with one shield and polyurethane jacket; rated to 105 °C (221 °F); 10 m (33 ft.) standard length |
| Sensor Type | Digital |
| Temperature Accuracy | ± 0.5 °C (± 0.9 °F) |
| Temperature Sensor | Sensor Pressure/Temperature Limits Digital: 6.9 bar |
| Transmission Distance | 100 m (328 ft.), maximum |
| Transmission Distance | 1000 m (3280 ft.), maximum when used with a termination box |
| Warranty | 12 months |
| Wetted Materials | PEEK or PPS, salt bridge of matching material with PVDF junction, glass process electrode, titanium ground electrode, and FKM/FPM O-ring seals (pH sensor with optional HF-resistant glass process electrode has 316 stainless steel ground electrode, and perfluoroelastomer wetted O-rings; consult factory for other available wetted O-ring materials) |
| What's included? | Includes: sensor with 33 ft cable and manual |
应用领域
Membrane Protection · Nutrient Monitoring · Nutrient Monitoring · Secondary Treatment · Secondary Treatment · Ultrapure Water
同系列其他配置
| 型号 | |
|---|---|
| DRD1P5.1 | Digital ORP Sensor, PEEK, Convertible, Non-Hazardous Environment |
| DRS5.1 | Digital ORP Sensor, Stainless Steel, Immersion, Non-Hazardous Environm |
| DRD1R5.1 | Digital ORP Sensor, PPS, Convertible, Non-Hazardous Environment |
| DRD2P5.1 | Digital Differential ORP Sensors, Peek, Convertible, Non-Hazardous Env |
资料下载
- Complete Water Analysis for the UPSTREAM OIL & GAS INDUSTRY
- Complete Water Analysis for the Food Industry
- ORP Sensors – Are They Really the Best Thing “After the Sliced Bread?
- Cyanide Waste Treatment. This note provides basic information about treatment of extremely toxic cyanide wastes commonly found in the plating industry.
- Electrochemistry Theory and Practice
- Introduction to Hach Services
- Complete Water Analysis for the Food Industry
- See your data. Trust your data. Mobile Sensor Management (MSM) ensures confidence in your water quality analysis
Related Products
HACHSC4500 Controller, Prognosys, 5x mA Output, 2 analog pH/ORP Sensors, without plug C1D2
View →
A
HACHPlug for electrolyte refill hole, Sension+ pH/ORP, pk/5
View →
HACHORP Encapsulated Sensor, PPS Body, Convertible, 5 Wire, Gold Electrode Material, 10-ft Cable
View →
HACHSC4500 Controller, Prognosys, 5x mA Output, 1 Analogue pH/ORP, 24 VDC, without plug
View →
A
HACHFlow-Thru Mounting Hardware, PVC, pH/Orp
View →
A
HACHBS870 Redox Buffer, 215 mV, 500 ml
View →
HACH2" CPVC Union Tee, for 1.5" pH/ORP Sensors
View →
HACH2" PVC Union Mounting Tee, For 1.5 inch pH/ORP sensors, No Junction Box
View →