产品概述
The Radiometer PHC3006-9 Combination pH Electrode has a glass body, Ag/AgCl reference system, refillable electrolyte (3M KCl + sat. AgCl) and porous pin junction. The PHC3006-9 has a long length of 150 mm with lower diameter of 6.5 mm for general purpose or semi-micro applications. The PHC3006-9 is a screw cap electrode and requires the CL114 cable (part no. A94L114) for compatibilty with Hach sensION+ benchtop pH meters (or any meter with a BNC connection).
主要特点
- The right probe for your application.:To meet your analysis needs, Radiometer Analytical electrodes are available with a variety of lengths, diameters and reference systems. There is a Radiometer electrode for every application.
- Glass sensors made for long-life and durable use.:Radiometer Analytical glass pH electrodes are made with highly shock-resistant glass, making them extremely tough. The average lifetime of a correctly maintained Radiometer glass pH electrode is approximately two years.
技术参数
| 参数名称 | 说明 |
|---|---|
| Dimensions (D x L) | 6.5 mm x 150 mm |
| Filling Solution | Refillable: 3 M KCl + sat. AgCl |
| Junction | Porous pin |
| Length | 150 mm |
| Material | Glass |
| Probe Type | Laboratory combination pH electrode |
| Range | 0 - 12 pH |
| Sensor Type | Glass (semi-micro diameter) |
| Special Features | Small diameter for semi-micro applications |
| Temperature Range | 0 - 80 °C |
| Thermistor | none (external required) |
| What's included? | Includes: Radiometer Analytical PHC3006-9 combination pH electrode with Certificate of Conformity and small bottle of internal electrolyte solution. |
应用领域
Municipal Water · Primary Treatment · QA/QC Lab · Surface Water
资料下载
- Temperature Compensation with pH Measurement
- Technical Note pH Trace Analysis
- What are the individual parts of a pH electrode?
- Technical note pH measurement system
- pH electrode filling
- Application Note: Learn how to really clean pH probes from individual sample contamination to maintain best performance of your pH probes
- Electrochemistry Theory and Practice
- Data Sheet: HQd pH Electrode Cleaning and Maintenance Guide
Related Products
HACHRadiometer Analytical PHC3031-9 Combination pH Electrode for Penetration Applications (glass body, Ag/AgCl ref., screw cap)
Radiometer Analytical PHC4006-9 Combination Calomel pH Electrode (l=158 mm, d=6.5 mm, glass body, screw cap)
pHC2501-8 Combined pH Electrode, Red Rod, Double Junction, BNC plug (Radiometer Analytical)
HACHpH Electrode Storage Solution, 500 mL
Radiometer Analytical PHC2401-7 Combination Red-Rod pH Electrode (glass body, type 7 plug)
HACHRadiometer Analytical PHG201-8 Glass pH Electrode (d=7.5 mm, BNC)
HACHRadiometer Analytical PHC3006L-9 Combination pH Electrode with extra long length, glass body, length=255 mm, d=6.5 mm, screw cap
HACH