Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

EZ4006.XXXXXXXX

EZ4006.XXXXXXXX
EZ4006 Chloride Analyzer
HACH EZ4006.XXXXXXXX
Online, automatic titration of Chloride in water monitoring applications

产品概述

Online, automatic titration of Chloride in water monitoring applications

State of the art titration platform The EZ4000 Series Analyzers are single-parameter titrators built on an industrial analytical platform. High precision dispensers, robust peristaltic pumps and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs. Unique flexibility in titration methods Every application starts with the basics: the right titrimetric technique for the parameter of interest, the measuring range and the water matrix. Depending on the change in the specific variables, the EZ4000 Series run either acid-base, redox, precipitation or photocolorimetric titration allowing for a unique flexibility. The EZ4006 Chloride Analyzers use potentiometric titration. They combine unparalleled expertise in online titration with a set of unique analysis, control and communication features in a compact footprint: - Wide standard measuring range of 0-500 mg/L Chloride - Smart automatic features - Control and communication via industrial panel PC - Analogue and digital output options - Multiple stream analysis (up to 8 streams) There are many additional options available. Please contact Hach for more details.

技术参数

参数名称说明
Alarm1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Ambient Temperature10 - 30 °C ± 4 °C deviation (50 - 86 °F ± 7.2 °F deviation) at 5 - 95% relative humidity (non-condensing)
Analog OutputsActive 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
CalibrationN.A.
CertificationsCE compliant / UL certified
Cycle Time10 - 15 minutes
Demineralized WaterFor rinsing / dilution
Digital OutputsOptional: Modbus (TCP/IP, RS485)
Dimensions (H x W x D)690 mm x 465 mm x 330 mm
DrainAtmospheric pressure, vented, min. Ø 32 mm
Earth ConnectionDry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Instrument AirDry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
InterferencesBromide, sulfide, iodide ions may interfere. Ferricyanide causes high results and must be removed. Chromate and dichromate interfere and should be reduced to chromic state or removed. Ferric iron interferes if present in an amount substantially higher than the amount of chloride. Chromic ion, ferrous ion and phosphate do not interfere. Fats, oil, proteins, surfactants and tar.
Lower Limit of Detection (LOD)5 mg/L
MaterialHinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated
Measurement MethodPotentiometric titration with silver nitrate (AgNO₃), conform with standard method APHA 4500-Cl (D)
Method NameTitrimetric
ModelEZ4006
Number of sample streams1, 2, 4 or 8
ParameterChloride
Power100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA
Power Supply100 - 240 VAC, 50/60 Hz
PrecisionBetter than 2% full scale range for standard test solutions
Protection ClassProtection class: Analyser cabinet: IP44 / Panel PC: IP65
Range25 - 500 mg/L Cl- Optional: 5 - 50 mg/L Cl- 5 - 125 mg/L Cl- 5 - 250 mg/L Cl- Internal dispenser dilution (max. factor 100)
Range25 ‐ 500 mg/L
Reagent RequirementsKeep between 10 - 30 °C (50 - 86 °F)
Sample Flow Rate100 - 300 mL/min
Sample PressureBy external overflow vessel
Sample QualityMaximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Sample Temperature10 - 30 °C (50 - 86 °F)
ValidationAutomatic; frequency freely programmable
Warranty12 months
Weight25 kg (55 lbs.)
What's included?EZ4006 Chloride Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x mV electrode, 2 x empty 10L Reagent Containers with Fittings (for Cleaning & Buffer Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for AgNO₃ Solution)

应用领域

Municipal Water · Ultrapure Water