产品概述
Online automatic titration of Calcium Hardness + Total Alkalinity in water
EZ5000 Series Analyzers are multi-parameter titrators that achieve excellent precision and accuracy. Depending on the parameter of interest, the measuring range and the water matrix the EZ5000 Series may use either potentiometry i.e. acid-base, redox or precipitation titration, where the endpoint is determined by a change in a specific variable, or photocolorimetry, where color change is used to determine the endpoint of the titration. The high precision dispenser for addition, robust peristaltic pumps for sampling and drain, and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs. Results you can rely on Smart automatic features for validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Sample lines and analysis vessel are cleaned with demineralized water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part. Flexibility that meets your needs EZ Series Alkalinity and Hardness Analyzers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyzer to match your application and operational needs. • The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options. • Analog and digital output options • Multiple stream analysis for up to 8 sample streams There are many additional options available. Please contact Hach for more details.
技术参数
| 参数名称 | 说明 |
|---|---|
| Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
| Ambient Temperature | 10 - 30 °C ± 4 °C deviation (50 - 86 °F ± 7.2 °F deviation)at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option) |
| Calibration | N.A. |
| Certifications | CE compliant / UL certified |
| Cycle Time | 20 - 30 minutes 40 minutes (+ Total Hardness Ca) |
| Demineralized Water | For rinsing |
| Digital Outputs | Optional: Modbus (TCP/IP, RS485) |
| Dimensions (H x W x D) | 690 mm x 465 mm x 330 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
| Interferences | Hardness: Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar. Alkalinity: Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally. |
| Lower Limit of Detection (LOD) | Calcium Hardness: ≤ 10 mg/L Total Alkalinity: ≤ 20 mg/L |
| Material | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated |
| Measurement Method | Acid-base titration (alkalinity only); Calmagite EDTA titration with LED dipping probe (combined) |
| Method Name | Titrimetric |
| Number of sample streams | 1, 2, 4 or 8 |
| Parameter | Calcium Hardness; Alkalinity, total |
| Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
| Precision | Better than 2% full scale range for standard test solutions |
| Protection Class | Protection class: Analyser cabinet: IP44 / Panel PC: IP65 |
| Range | Calcium Hardness: 10 - 100 mg/L CaCO₃; Total Alkalinity: 20 - 500 mg/L CaCO₃ |
| Range | Ca: 10 - 100 mg/L CaCO₃; Alk: 20 - 500 mg/L CaCO₃ |
| Reagent Requirements | Keep between 10 - 30 °C (50 - 86 °F) |
| Sample Flow Rate | 100 - 300 mL/min |
| Sample Pressure | By external overflow vessel |
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Sample Temperature | 10 - 30 °C (50 - 86 °F) |
| Validation | Automatic; frequency freely programmable |
| Warranty | 12 months |
| Weight | 25 kg (55 lbs.) |
应用领域
Influent for Wastewater · Membrane Protection · Primary Treatment · Secondary Treatment
同系列其他配置
| 型号 | |
|---|---|
| EZ4003.XXXXXXXX | EZ4003 Free Alkalinity Analyzer |
| EZ4004.XXXXXXXX | EZ4004 Total Alkalinity Analyzer |
| EZ4041.XXXXXXXX | EZ4041 Total Hardness Analyzer |
| EZ4043.XXXXXXXX | EZ4043 Total Hardness Analyzer |
| EZ4044.XXXXXXXX | EZ4044 Calcium Hardness Analyzer |
| EZ5001.XXXXXXXX | EZ5001 Total / Free Alkalinity Analyzer |
| EZ5002.XXXXXXXX | EZ5002 Total Hardness Analyzer (TH, THCa) |
| EZ5003.XXXXXXXX | EZ5003 Total Hardness + Free Alkalinity Analyzer |
| EZ5004.XXXXXXXX | EZ5004 Total Hardness + Total Alkalinity Analyzer |
| EZ5005.XXXXXXXX | EZ5005 Total Hardness + Total / Free Alkalinity Analyzer |
| EZ5006.XXXXXXXX | EZ5006 Total Hardness / Total Calcium Hardness + Total / Free Alkalini |
| EZ5011.XXXXXXXX | EZ5011 Total Hardness + Total Alkalinity Analyzer |
资料下载
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Analyzer Seri EZ Online Solusi Lengkap
- EZ Series Online Analyzers
- Analizadores en continuo de la serie EZ
- Analisadores on-line da série EZ
- Analyseurs en ligne série EZ
- EZ 시리즈 온라인 분석기 완벽한 솔루션 제공
Related Products
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
Accu4 Spare Chamber with Plumbing, High Pressure
HACH