Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

LXV525.99A12601

LXV525.99A12601
Product family: SC4500 Controller with Prognosys and Profibus, Analog
SC4500 Controller, Prognosys, Profibus DP, 1 Analog UPW Conductivity Sensor, 100-240 VAC, without power cord
HACH LXV525.99A12601
Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller f

产品概述

Ready for Now. Ready for the Future.

Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller from HachⓇ is designed to integrate easily into your current system while allowing you to upgrade as your capabilities advance, without having to replace inventory. With a wide range of analog and digital connectivity options and the availability of intelligent instrument and data management features, the SC4500 unlocks the future, today.

主要特点

  • Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
  • No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.
  • The Connectivity Options You Need:The Controller is Smart Monitoring enabled and provides local communication to SCADA or a PLC. From analog and advanced digital protocols to Wi-Fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.

技术参数

参数名称说明
Altitude3000 m (9842 ft) maximum
Analog Output Functional ModeLinear, PID
Communication (optional)Analog: Five 0 - 20 mA or 4 - 20 mA analog outputs on each analog output module Up to two analog Input modules (0 - 20 mA or 4 - 20 mA). Each input module replaces a digital sensor input. Digital: Profibus DPV1 module Modbus TCP Modbus RS Profinet IO module Ethernet IP module HART module
Compatible InstrumentsCompatible Sensors and Analyzers / Software Version (Release Year) Amtax sc / V2.30 (2018) or higher A-ISE sc / V1.02 or higher AN-ISE sc / V1.08 (2013) or higher N-ISE sc / V1.02 or higher Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher NT3100sc/NT3200sc Phosphax sc / V2.30 (2018) or higher Phosphax sc LR/MR/HR / V1.01 (2018) or higher TSS sc / V41.73 (2013) or higher Solitax sc / V2.20 (2013) or higher TU5300sc, TU5400sc / V1.34 (2017) or higher SS7 sc (in Bypass) / V1.01 (2006) or higher Ultraturb sc / V3.06 (2017) or higher 1720E / V2.10 (2006) or higher Sonatax sc / V1.15 (2016) or higher CL17sc / V2.7 (2019) or higher CL10sc / V1.14 (2013) or higher 9184sc, 9185sc, 9187sc* / V2.03 (2013) or higher Uvas plus sc / V3.01 (2017) or higher LDO 2 sc* / V1.22 (2013) or higher 3798sc* / V2.03 (2013) or higher 3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher 3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higher pHD sc*, pHD-S sc / V3.10 (2016) or higher 1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higher RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher *Hardware Version1 of instrument is not supported
Compatible Network TechnologiesGSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.) CDMA (e.g. Verizon)
Compliance CertificationsCE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)
Conduit Openings½" NPT conduit
DescriptionMicroprocessor-controlled and menu-driven controller that operates the sensor
Dimensions½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display3.5-inch TFT colour display with capacitive touchpad
Enclosure RatingUL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish
Indoor/OutdoorOutdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
Installation CategoryCategory II
Material EnclosuresPolycarbonate, aluminum (powder coated), stainless steel
MeasurementsOne analog device connector
MountingWall, Pole, or Panel Mounting
Network ConnectivityLAN: Two Ethernet connectors (10/100 Mbps) Cellular: External 4G Wi-Fi
Operating Temperature Range-20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
OutputsProfibus DP
Pollution Degree4
Power Requirements (Voltage)100 - 240 VAC ±10%, 50/60 Hz; 1 A
Power SupplyNo Plug
Protection ClassI, connected to protective earth
RelaysTwo relays (SPDT); Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG) AC controller Maximum switching voltage: 100 - 240 VAC Maximum switching current: 5 A Resistive/1 A Pilot Duty Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty DC controller Maximum switching voltage: 30 VAC or 42 VDC Maximum switching current: 4 A Resistive/1 A Pilot Duty Maximum switching power: 125 W Resistive/28 W Pilot Duty
Sensor Input #1Analog UPW Conductivity
Software AvailableNon-Claros + Embedded Prognosys
Storage Conditions-20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
USB PortUsed for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
Warranty12 months
Weight3.7 lb (controller only, w/o modules)
What's included?Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware

应用领域

Municipal Water

同系列其他配置

型号
LXV525.99A12701SC4500 Controller, Prognosys, Profibus DP, 1 Analog UPW pH/ORP Sensor,
LXV525.99A12661SC4500 Controller, Prognosys, Profibus DP, 2 Analog UPW Conductivity S
LXV525.99A12761SC4500 Controller, Prognosys, Profibus DP, 1 Analog UPW pH/ORP + 1 Ana
LXV525.99A12771SC4500 Controller, Prognosys, Profibus DP, 2 Analog UPW pH/ORP Sensors

资料下载

5 models · click to collapse