产品概述
Intellical PHC101 is a digital combination pH electrode with built-in temperature sensor. PHC101 has low maintenance needs thanks to a non-refillable gel-filled single open reference junction. The laboratory version of this pH electrode is shockproof with its epoxy plastic body protecting down to the glass bulb sensing element. The Electrode is available with a 3 or 1 m cable. The PHC101 electrode is ideal for measuring pH in wastewater, drinking water and general aqueous applications. The PHC101 is not suitable for use with organic solvents, low ionic strength, or samples with pH less than 2.
主要特点
- IntelliCAL PHC101 provides fast, stable response in wastewater applications:Unique solid gel probe and open reference junction specifically designed for pH measurement in wastewater.
- IntelliCAL digital pH probe provides ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and pH probe serial number
- IntelliCAL digital pH probe alerts the user when re-calibration is needed:No guesswork needed to provide the most reliable and accurate results with each measurement.
- IntelliCAL digital pH probe can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±0.02 pH |
| Application | Clean & Dirty Samples |
| Cable Length | 1 m (3.28 ft) |
| Electrode Type | Non-Refillable Gel Reference Element |
| Junction | Open Junction |
| Kit? | No |
| Length | 175 mm (6.89 in.) |
| Method Type | Field: Non-Refillable Gel Reference Element |
| Minimum Sample Depth (mm) | 20 mm |
| Parameter | pH |
| Probe Type | Standard |
| Product Kit | Model: PHC101 Accessories Included: None |
| Range | 2 - 14 pH |
| Reference Type | Ag/AgCl |
| Resolution | 0.001/0.01/0.1 |
| Sample depth | 20 mm (0.79 in.) |
| Sensor material | Epoxy |
| Sensor Type | pH Glass |
| Sodium (Alkalinity) error | -0.6 pH at pH 12.6 in 1 M NaOH |
| Special Features | Double junction reference |
| Temperature Accuracy | ±0.3 °C (±0.54 °F) |
| Temperature Range | 0 - 50 °C (32 - 122 °F) |
| Temperature Resolution | 0.1 °C (0.18 °F) |
| Test requirements | Parameter Needed: pH Minimum Sample Depth (mm): 20 |
| Thermistor | ATC |
| Warranty | 6 months |
| Weight | 0.1 kg |
| What's included? | IntelliCAL PHC101 Laboratory pH electrode with storage soaker bottle, 1 m cable, Test certificate, and Basic User Manual. |
应用领域
Municipal Water · Potable Water · Production Water · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| PHC10105 | IntelliCAL PHC101 Field Low Maintenance Gel Filled pH Electrode, 5 m C |
| PHC10110 | IntelliCAL PHC101 Field Low Maintenance Gel Filled pH Electrode, 10 m |
| PHC10115 | IntelliCAL PHC101 Field Low Maintenance Gel Filled pH Electrode, 15 m |
| PHC10130 | IntelliCAL PHC101 Field Low Maintenance Gel Filled pH Electrode, 30 m |
| PHC70501 | IntelliCAL PHC705 Laboratory General Purpose RedRod Refillable Glass p |
| PHC72501 | IntelliCAL PHC725 Laboratory Low Ionic Strength Media RedRod Refillabl |
| PHC73501 | IntelliCAL PHC735 Laboratory Dirty Media RedRod Refillable Glass pH El |
| PHC74501 | IntelliCAL PHC745 Laboratory Clogging Media RedRod Refillable Glass pH |
| PHC705A01 | IntelliCAL PHC705 Laboratory High Alkalinity Range RedRod Refillable G |
| PHC72901 | IntelliCAL PHC729 Laboratory Surface Measurements RedRod Refillable Gl |
| PHC70501AP | IntelliCAL PHC705 Laboratory General Purpose RedRod Refillable Glass p |
| PHC72501AP | IntelliCAL PHC725 Laboratory Low Ionic Strength Media RedRod Refillabl |
| PHC72901AP | IntelliCAL PHC729 Laboratory Surface Measurements RedRod Refillable Gl |
| PHC74501AP | IntelliCAL PHC745 Laboratory Clogging Media RedRod Refillable Glass pH |
| PHC73501AP | IntelliCAL PHC735 Laboratory Dirty Media RedRod Refillable Glass pH El |
| PHC80501AP | IntelliCAL PHC805 Laboratory General Purpose Refillable Glass pH Elect |
| PHC10103 | IntelliCAL PHC101 Laboratory Low Maintenance Gel Filled pH Electrode, |
| PHC30101 | IntelliCAL PHC301 Laboratory General Purposes Refillable pH Electrode, |
| PHC30103 | IntelliCAL PHC301 Laboratory General Purposes Refillable pH Electrode, |
| PHC28101 | IntelliCAL PHC281 Water Quality Laboratory Refillable pH Electrode, 1 |
| PHC28103 | IntelliCAL PHC281 Water Quality Laboratory Refillable pH Electrode, 3 |
| PHC20103 | IntelliCAL PHC201 Laboratory General Purposes Gel Filled pH Electrode, |
| PHC20101 | IntelliCAL PHC201 Laboratory General Purposes Gel Filled pH Electrode, |
| PHC80501 | IntelliCAL PHC805 Laboratory General Purpose Refillable Glass pH Elect |
31 更多配置.
资料下载
- Technical note pH measurement system
- Application Note: Learn how to really clean pH probes from individual sample contamination to maintain best performance of your pH probes
- Poster: Cleaning and maintenance of pH probes
- Poster: Limpieza y mantenimiento de las sondas de pH
- Poster: Nettoyage et entretien des sondes de pH
- Poster: Limpeza e manutenção das sondas de pH
- pH Logbook: How to enter your data
- Electrochemistry Theory and Practice
Related Products
HACHRadiometer Analytical PHC3105-9 Combination pH Electrode (epoxy body, gel electrolyte, screw cap)
HACHRadiometer Analytical PHC3031-9 Combination pH Electrode for Penetration Applications (glass body, Ag/AgCl ref., screw cap)
Radiometer Analytical PHC4006-9 Combination Calomel pH Electrode (l=158 mm, d=6.5 mm, glass body, screw cap)
Radiometer Analytical PHG200-8 Glass pH Electrode for Microsamples (d=4 mm, BNC)
HACHRadiometer Analytical PHG201-8 Glass pH Electrode (d=7.5 mm, BNC)
HACHpH Electrode Storage Solution, 500 mL
HACH