Portable Samplers AS950 Standard
Portable Samplers AS950 Standard
HACH PSAS950 Standard
Configurable Models 9 models
Portable Samplers AS950 Standard

产品概述

Sampling has never been this easy.

The AS950 Portable Sampler simplifies sampling with a large, full-color display for intuitive, single-screen programming, USB upload and download capabilities and the ability to copy programs sampler to sampler to save time on tedious programing, and an error alert and status screen to eliminate uncertainty and simplify troubleshooting. Weighing only 12.7 kg, the AS950 Portable Sampler is designed for accuracy and convenience.

主要特点

  • Easiest and most intuitive operation:The large full color display and intuitive programming give you access to all your programmable criteria on a single screen - eliminating scrolling through menus and supporting error-free operation.
  • Most convenient data transfer and programming available:The AS950 is the only sampler that utilises a USB drive to upload and download data and copy programs from one sampler to another.
  • Confidence in your sampling process:The program status screen instantly communicates alarms, missed samples and program progress for quick and easy troubleshooting.
  • Field convertible for compact or discrete sampling:Weighing only 15 kg, the AS950 portable standard sampler is designed for accuracy and convenience. Quickly switch between composite and discrete sampling in the field. Configurable for single or multiple bottle applications, it is specifically designed for use in 18-inch manholes.
  • Easy maintenance at low cost:Spring-mounted rollers provide long tubing life keeping maintenance costs low. The desiccant and pump tubing can easily be accessed; the replacement is possible without any tools. The rugged see-through pump cover is made for a quick visual inspection.

技术参数

参数名称说明
AlarmConfigurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Automatic ShutdownMultiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected) Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Base ConfigurationPortable Standard
Base TypeStandard
Body materialImpact resistant ABS plastic, 3-section construction Double-walled base with 2.54 cm insulation, direct ice contact with bottles (Sampler)
Bottle SetComposite 2.5 gallon polyethylene bottle kit
CertificationsCE, UL
Communication CapabilitiesUSB and optional RS485 (Modbus)
Data LoggingSAMPLE HISTORY - Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).

MEASUREMENTS - Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.

EVENTS - Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
DiagnosticsView event and alarm logs as well as maintenance diagnostics
DimensionsStandard Base: 50.5 cm x 69.4 cm (19.9 x 27.3 in.)|Compact Base: 44.1 x 61 cm (17.4 x 24 in.)|Composite Base: 50.28 x 79.75 cm (19.8 x 31.4 in.)
Display1/4 VGA, Color; self-prompting/menu-driven program
Factory Installed OptionsTWO SENSOR PORTS Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors |RAIN/RS485 PORT Accepts Hach Rain Gauge (not included) or can be used as RS485 communications |NON-CONTACT LIQUID DETECT Sample volume accuracy for applications that require complete tubing replacement | Please contact your Hach sales representative for details.
Housing MaterialPC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
InputsOne 0/4-20 mA input for flow pacing
IntakeStrainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications Purge: Air purged automatically before and after each sample; duration automatically compensates for varying intake line lengths Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Internal Clock±1 second per day at 25 °C (77 °F)
Languagesen, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko
Lock FunctionAccess code protection prevents tampering
Manual SamplingInitiates a sample collection independent of program in progress
MemorySample history: 4000 records; Data log: 325,000 records; Event log: 2000 records
Operating ModeContinuous or non-continuous
Operating Temperature Range0 - 50 °C
Power Requirements (Voltage)12V Battery
Power SupplyBattery, 12V Lead acid, 3 pin
Probes includedNo
ProgramsDual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
Pump flow rate4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical
Rain Gauge EnabledNo
Rain Gauge InputNo
Sample Container1 x 10 L PE
Sample IntervalSelectable in single increments from 1 to 9,999 flow pulses or 1 to 9,999 mins in one minute increments
Sample PumpHigh-speed peristaltic, dual roller, with 0.95 ID x 1.6 OD cm (3/8 ID x 5/8 in. OD) pump tube
Sample Temperature0 - 60 °C
Sample Transport Velocity2.9 ft/s (0.9 m/s) with 15 ft (4.6 m) vertical lift, 16 ft of 3/8-in. vinyl intake tubing, 70°F (21°C) and 5000 ft elevation
Sample TriggerWhen equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
Sample VolumeProgrammable in 10 mL increments from 10 - 10,000 mL
Sample Volume AccuracyTypical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sample Volume RepeatabilityTypical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sampling ModePacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
Status MessagesCommunicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Storage Conditions-30 - 60 °C
Suction Hose Outer Diameter1/4" and 3/8" ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
TubingPump tubing: 9.5 mm ID x 15.9 mm OD Silicone Intake tubing: 1.0 - 4.75 m minimum length, 1/4" or 3/8" ID Vinyl or 3/8" ID PTFE-lined Polyethylene with protective outer cover (black or clear)
User InterfaceMembrane switch keypad with 2 multiple function soft keys
User Interface LanguagesChinese, English, French, German, Italian, Spanish, Portuguese
Vertical LiftMaximum of 28 ft using 29 ft of 3/8-in. vinyl intake tube at sea level at 20-25°C (68-77°F)
Warranty12 months
Weight15 kg
What's included?1 ea. AS950 controller on standard portable base 1 ea. 12V battery (8754400) 1 ea. Bottle kit (PS010030) includes 2.5 gallon polyethylene bottle w/cap (1918), container support (1502) and full bottle shut-off (8996) 1 ea. 25' vinyl intake tubing (920) 1 ea. strainer (926 (Battery charger 8753500US sold separately)

应用领域

Discharge · Flow Monitoring · Groundwater · Industrial Wastewater · Influent for Wastewater · Municipal Water · Pre-Treatment · Primary Treatment · Production Water · QA/QC Lab · Regulations · Secondary Treatment · Source Water · Storm Water · Surface Water · Water Cycle · Water Reuse

同系列其他配置

型号
ASP.CXXXS241XXAS950 Portable Standard Sampler, 115 V, Discrete (24x) 1 L Bottle Kit,
ASP.CSRXS141XXAS950 Portable Standard Sampler, 2 Sensor Port Options, Rain Gauge, 12
ASP.CSXXS121XXAS950 Portable Standard Sampler, 2 Sensor Port Options, 12 V, Composit
ASP.CSXXS141XXAS950 Portable Standard Sampler, 2 Sensor Port Options, 12 V, Discrete
ASP.CSXXS12113AS950 Portable Standard Sampler, 2 Sensor Port Options, 12 V, Composit
ASP.CXXXS141XXAS950 Portable Standard Sampler, 12 V, Discrete (24x) 1 L PE Bottle Ki
ASP.CXXXS341XXAS950 Portable Standard Sampler, 230 V, Discrete (24x) 1 L Bottle Kit,
ASP.CSRXS12113AS950 Portable Standard Sampler, 2 Sensor Port Options, Rain Gauge, 12

资料下载

9 models · click to collapse