产品概述
Expert Chloride test made simple.
Chloride TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For determination of Chloride by the Iron(III)-thiocyanate method. With Chloride TNTplus reagents, simply add your sample to the vial and invert to mix. After zeroing with the included zero vial insert the sample vial into your Hach spectrophotometer! The Direct Read Technology will provide your Chloride results to the nearest mg/L! The new chloride TNT879 covers two different ranges: 1 - 70 mg/L and 70 - 1,000 mg/L. Upgrade from traditional chloride methods to TNTplus Chloride reagents today! 24 Chloride vials and one zero vial per box.
主要特点
- Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
- Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
技术参数
| 参数名称 | 说明 |
|---|---|
| Instrument | DR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000 |
| Method Name | Iron(III)-thiocyanate |
| Method Number | 10291 |
| Number of tests | 24 |
| Parameter | Chloride |
| Platform | TNT plus™ |
| Range | 1 - 70 mg/L Cl 70 - 1000 mg/L Cl |
| Sample Requirements | The pH of the water sample must be between pH 3 - 10. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F). |
| Special Remarks | 2 measuring ranges within 1 test |
| Storage Conditions | 2 - 8 °C (keep refrigerated) |
应用领域
Boiler Water · Industrial Wastewater · Potable Water · Surface Water
资料下载
Related Products
HACHPhosphoric Acid Solution, 1.0 Molar 5 Gallon
HACHAmino acid reagent powder pillows for LR silica, 25 mL, pk/1000
HACHRochelle Salt-PVA Reagent, 500 mL
HACHToluene, 4 L
HACHSodium carbonate solution, 500 mL
Nutrients Basic Reagent Set, TNTplus
HACHRapid Silver Reagent Powder Pillows, pk/100
HACH