HANNA Instruments BL-131-20
BL-131-20 Automatic Controller for Pools and Hot Tubs The BL-13X series of pool dosers and controllers offer an alternative to manual measurement and dosing processes, with around-the-clock monitoring

Overview

BL-131-20 Automatic Controller for Pools and Hot Tubs The BL-13X series of pool dosers and controllers offer an alternative to manual measurement and dosing processes, with around-the-clock monitoring and automatic logging for consistent sanitation following setup. The BL-131 controller for pools measures and controls the pH and free chlorine levels within the water, utilising the ORP or REDOX principle as a consistent and accurate indicator of sanitiser effectiveness. The BL-131-20 includes a flow cell.

Our team can provide advice and guidance on the best solution for sanitation maintenance in your pool, spa or hot tub. About the BL-131 Controller Built-in dosing pumps with adjustable flow and proportional band This compact controller includes two built-in peristaltic dosing pumps with proportional control, allowing the dosing frequency to be adapted to the size of the body of water to effectively maintain the set point for pH and ORP.

Large bodies of water, such as full-size pools, can use a small proportional band, such 0.1 pH, for more frequent dosing, while a controller on a hot tub can be configured with a larger proportional band, such as 1.0 pH, to avoid significant swings in water chemistry. An adjustable flow rate further allows the BL-131 to be adapted to different pool and hot tub size requirements, with a range from 0.5 to 3.5L/h. This customisation option provides complete control over the amount of chemical dosed at one time, further preventing swings in pH or ORP.

Alarm and notification system The BL-131 controller features a comprehensive alarm and notification system, including multicoloured LED indicators providing continual feedback on dosing, meter status and service. A programmable alarm system provides flexibility in setting alarms for low and high levels of both pH and ORP within the water. When an alarm activates, dosing stops, providing overdosing protection to prevent unnecessary chemical dosing of the water.

A built-in temperature sensor also allows for temperature alarms, alerting the user if the temperature reaches above or below a set limit. In outdoor pools and hot tubs, this functionality provides a notification that there may be a risk of water freezing in the pipes, allowing for prompt action. Interlocking sanitation control The efficacy of pool sanitisers is affected by the pH value of the water.

The BL-131 measures and doses both pH and ORP in tandem to ensure the pH value is at a set point before dosing to increase or reduce ORP. A range of 650-750 mV at 7.2 pH indicates proper water treatment. By utilising the pH value, the BL-13X series prevents the overuse of chemicals to balance the water, reducing costs.

Customisable logging intervals This pool controller offers complete data logging, with measurement reading intervals that can be tailored to suit personal preference or to meet compliance requirements. Measurement reading intervals can be set to 30 seconds, 1 minute, 5 minutes, 15 minutes, 30 minutes or 1 hour, refreshing each day or following calibration. pH, ORP and temperature values are all logged in addition to the last calibration data, event information and setup configuration.

Additional external dosing options The BL-131 controller can be used for pools of all sizes, with the addition of 2 relays that can be connected to larger, external dispensing pumps. These relays provide greater flexibility to use the BL-13X series dosers with larger pools that exceed the limits of the built-in pumps. Available in two configurations The BL-13X series is available in two different configurations to suit your requirements: In-line: Where the direct probe and chemical injection fittings are installed onto existing piping Flow cell: Where an optional flow cell is included during installation, allowing for calibration and probe maintenance without the need to shut down the recirculation pump If you are unsure which solution would be the ideal choice for your pool or hot tub, speak to our pool specialists directly.

We can provide personalised advice for your requirements. Achieve HSG282 compliance The BL-131 and BL-132 controllers for hot tubs, spas and pools help businesses comply with HSG282 legislation.

Under the HSE's 2017 legislation, both pH and sanitation should be consistently measured and reported to reduce the risk of legionella and other pathogens. Learn more about HSG282 here . About the HI-1036-18XX Digital Probe The HI-1036-18XX is a digital combined probe available in five different cable lengths.

This probe connects to the BL-131 and measures pH, ORP and temperature in one, with a potential matching pin incorporated to prevent ground loop effects and system damage. The pH glass for this probe produces stable quick equilibration even in low-conductivity waters. The sensor is designed to produce a zero mV value near pH 4 to stop process control if it is broken, triggering an alarm state from the controller and disabling active pumps.

The ORP sensing surface of the probe is a large, smooth-surfaced platinum band that encircles the circumference of the temperature probe. It is referenced to the Ag/AgCl reference electrode (3.5M KCl). The ORP and pH sensors and reference electrode utilise a differential measurement technique.

This technique is known to stay in service and provide accurate measurements under a wide range of conditions that may cause conventional pH probes to produce inaccurate measurements. The following options are available for the HI-1036-18XX: HI-1036-1802 probe with 2 m (6’7”) long cable HI-1036-1805 probe with 5 m (16’5”) long cable HI-1036-1810 probe with 10 m (32’9”) long cable HI-1036-1815 probe w FAQs How do I order the BL-131?

You can order the BL-131 controller for hot tubs and pools by getting in contact with our pool specialists directly to discuss the purchase and installation of these controllers from the Hanna Pool Line range. Can I get a pool controller demonstration? Our pool specialists can talk you through the functionality and configuration of the BL-131 and other BL-13X controllers.

Is the BL-131 suitable for hot tubs? This pool controller is extremely customisable and suits the scale and requirements of a wide range of bodies of water.

This includes small hot tubs, large hot tubs, spas, outdoor pools and indoor pools. What is the difference between the BL-131 and BL-132? The BL-131 has all of the customisability and functionality of the BL-132.

The key difference between these models is connectivity to the Hanna Cloud App. Instead, the BL-131 features analogue outputs for connection to an external chart recorder or dataloggers. Learn more about Hanna Cloud and the BL-132 here.

Specifications

ParameterValue
SKUBL-131-20
pH range0.00 to 14.00pH
pH Resolution0.01pH
pH Accuracy (@25°C+-0.05pH
pH CalibrationpH buffer calibration automatic, two-point (4.01, 7.01, 10.01pH); pH process and ORP: adjustable, single point
pH controllerProportional feed using adjustable set point and adjustable proportional band; delay to start at power-on and overdosing protection using overfeed safety timer
mV range+-2000mV
mV Resolution1mV
mV Accuracy @ 25°C+-5mV
ORP (mV) calibrationsingle-point, adjustable
ORP ControllerProportional feed using adjustable set point and adjustable proportional band; delay to start at power-on and overdosing protection using over feed safety timer, pH regulator interlocked
Temperature ˚C range-5.0 to 105.0˚C
˚C Resolution0.1˚C
˚C Accuracy @25°C+-1.0˚C
Temperature Compensationautomatic, -5.0 to 105.0˚C for pH
Additional Specifications
AlarmsHigh and low with enable/disable option for all parameters. Alarm is triggered after a user specified time.
Log Features:• Automatic logging for pH, ORP, air and solution temperature measurements • Configurable logging interval: 30 seconds; 1; 5; 15; 30; 60 minutes • 300 days logging, depending on selection logging interval (capacity of 100 lots) • Recall data displayed as a plot: 7 days or 6 hours zoom options; Overview of (history/details) measure range registered values ie minimum, maximum, average • Logged event type: setup, alarms, errors, warnings, calibration, power outage (capacity of 100 records, oldest record being overwritten) • Export to USB flash drive (USB C-port) of log files in CSV format
BL-132-20 Ethernet inputEthernet connector (Rj-45) 10/100 Mbps connection
Meter Password ProtectionPassword protected setup, calibration, and log recall
Alarm SystemIntuitive alert system based on LED colour coded alarm system Alarm filtering options Alarm relay control based on user set up filters
USB-C portData export to USB flash drive; software update
GLPpH/ORP
Alarm RelaySPDT; activated by selectable pH/ORP/temperature alarm conditions; Auxillary Acid/Base pump relay (SPST) Auxillary Chlorine pump relay (SPST) Recirculation pump relay (SPDT) All relays are fuse protected with 2A time delay 5x20mm cartridge fuses. To be replaced only with time delay glass/ceramic 5x20mm cartridge fuse of same rating; All relays are rated for 250/30VDC 2A resistive load
Analogue Outputs (BL-131 only)Three galvanised isolated, user configurable analogue outputs, 4 to 20mA Current sensing resistor ≤ 500 Ω Accuracy ˂0.5 % FS
Digital inputs (3)Galvanic isolated, powered contact, digital input Low level in acid/base tank (contact open) Low level in chlorine tank (contact open) Hold mode (contact open)
Probe inputProbe type: HI-1036-1802 Multiparameter digital probe with pH, ORP, temperature sensors and a matching pin; IP65 connector, Galvanic isolation; RS48S interface
Power supply100-240 VAC
Environment0 to 50°C, max 95% RH non-condensing
Dimensions245 x 188 x 55 mm (73mm with pumps)
Weight1700g
CasingWall mounted internal pumps, IP65 rated
Ordering Information
Flow Cell Configuration:
BL-131-20 & BL-132-20pH/ORP/Temperature pool controller is supplied with HI-1036-1802 pH/ORP/temperature digital probe with matching pin; BL-130-900 air temperature probe; panel mounted flow cell; flow cell panel; valve for flow-cell connection with fittings x 2 and tubing 10m, saddle for valves 50mm pipe (2), saddle for electrode 50mm (1), fittings for electrode injector (2), saddle for injectors 50mm (2), peristaltic pump tubing (2), silicon oil dropper bottle; pvc aspiration and injection tubing – 10m, aspiration filter (2), cable gland gasket, 20ml sachets containing pH 7.01 buffer (3), 20ml sachets containing pH 4.01 buffer (3), 20ml sachet of 470mV ORP test solution, power cable and Quick Reference Guide with QR Code for manual download, quality certification for meter and probe.
BL-132 Cloud Connectivity
BL-132-20 is connected to Hanna Cloud using a secured connection:• Device Identity Registry • Policy-based authorisation of security keys
The instrument will send status information to Hanna Cloud with a defined period.• Readings: pH, ORP, temperature • Events: alarms/warnings/errors • Peripheral status: LEDs • Last dosed acid and chlorine volumes • GLP info
Setup information is sent or configured on the Hanna Cloud.
Configured data• Alarm settings • Dosing settings • General settings • Remote Hold mode
Read data• System: meter information (model, FW version, OS version, serial number), • probe information (type, FW version, serial number)
“Remote Hold“ mode (configurable remotely)• Emergency mode that can be remotely triggered via web application • Pumps deactivation mode • Cancelled manually from the controller menu

Accessories

  • HI-70614L: HI-70614L Pool Line general purpose cleaning solution, 500mL
  • HI-700044P: HI-700044P Pool Line 4.01 pH Buffer Solution, 25 x 20 mL sachets
  • HI-700074P: HI-700074P Pool Line 7.01 pH Buffer Solution, 25 x 20 mL sachets
  • HI-703004L: HI-703004L Pool Line Electrode storage solution, 500 mL bottle
  • BL-123-70: BL-123-70 Pool Line Maintenance kit for pH and ORP electrodes
  • HI-700224P: HI-700224P Pool Line ORP Test Solution 470mV - 25 x 20mL sachets