HANNA Instruments BL-135-20110
BL-135-20110 Salt Pool Controller with Chlorine Generator 10 g/h Output, pH Control and External Dosing and Analog Outputs. The Hanna Instruments BL135 Salt Swimming Pool Controller and BL130-7X0 Salt

Overview

BL-135-20110 Salt Pool Controller with Chlorine Generator 10 g/h Output, pH Control and External Dosing and Analog Outputs. The Hanna Instruments BL135 Salt Swimming Pool Controller and BL130-7X0 Salt Chlorinator is designed to automate and control free chlorine, pH, and disinfection levels in saltwater swimming pools. The system uses electrolysis to convert dissolved salt (sodium chloride) in the water into hypochlorous acid (HOCl) to sanitize the pool.

Hypochlorous acid (HOCl) is the form of chlorine most effective at destroying pathogens. HOCl is formed in its highest concentrations between pH 7.2 and pH 7.4, and serves as a disinfectant, oxidiser, and has residual protection. The controller displays the continuous measurements of pH / ORP (redox), free chlorine values, as well as water and air temperatures, and the salt level of the pool water while water is circulated past the HI-1038-2802 pH / ORP probe and the HI-1040-1801 chlorine probe.

The BL135 Salt Swimming Pool Controller automates chlorine generation and acid or base additions to configured setpoints or time periods. Chlorine is generated by the BL130-7X0 chlorinator in a flowing system that requires the pool’s recirculation pump to be active. In automatic mode, chlorine generation only starts after the pH setpoint has been reached.

Acid or base additions use the integrated peristaltic pump with proportional control to prevent overdosing. Other specifications available in the Analog range: BL-135-20120 Salt Pool Controller with Chlorine Generator 20 g/h Output, pH Control, External Dosing and Analog Outputs. BL-135-20130 Salt Pool Controller with Chlorine Generator 30 g/h Output, pH Control, External Dosing and Analog Outputs.

Sanitation monitoring and control The BL-135 system relies on a two-tier approach for automated chlorine management and water-sanitation monitoring. The HI-1040-1801 membrane-covered chlorine electrode measures the actual concentration of free chlorine (mg/L) in the pool water and is used for primary control. This probe contains a chlorine sensor for real-time monitoring of chlorine levels.

The HI-1038-2802 pH sensor is highly effective at measuring pool- water alkalinity thus monitoring the real-time disinfection efficacy. This probe contains pH, ORP, and temperature sensors as well as reference and salinity electrodes in a single body. The ORP (redox) sensor is gold.

The salinity pins are titanium, and the probe body is PVDF. The system uses the pH sensor to compensate the signal, ensuring that even if the pH drifts slightly, the chlorine reading remains accurate. BL-130-7X0 chlorinator control The chlorinator control can automatically regulate chlorine production using chlorine (Cl) setpoints and measurements as well as fixed chlorine production.

It features a Fixed Mode, Pool Startup Mode, a Boost and Scheduled Boost Mode, and Pool Cover detection. Fixed mode - A “Fixed” mode may be set for proportional chlorine generation. The proportional generation method varies the voltage and amperage for the chlorine generation percentage (%) and continuously produces chlorine.

The “Fixed” mode, when Extend Cell option is enabled, runs the chlorine generator intermittently at 100% power (with off periods). Pool startup mode - “Pool Startup” mode enables automatic, independent chemical dosing based on pH and chlorine setpoints for up to 12 hours. Boost & scheduled boost mode - The “Boost Chlorination” feature provides maximum chlorine production for configured amount of time.

It then switches back to previous setting i.e. AUTO or FIXED. Users can schedule 100% output for specific times on the specified days of the week to align with heavy usage.

Pool cover detection - The chlorine production is decreased if a pool cover it detected and the cover alarm is triggered. Main feature points All in one chlorine management, pH control, and saltwater chlorination disinfection package, complete with measurement probes Continuous measurement and display of free chlorine values, pH/ORP (mV) values, water and air temperature, salt level Integrated peristaltic pump with proportional control for pH control to prevent overdosing Chlorinator (salt electrolysis cell) to produce chlorine disinfectant from salt water Available with a variety of cell sizes and output capacity to suit different pool sizes and needs Programmable modes for automatic chlorinator control using: Free chlorine sensor measurement, Fixed and Auto Mode, Pool Startup Mode, Boost Mode, Pool Cover Mode Self-cleaning electrolysis cell inverts polarity to remove deposits from water hardness Dosing resumed on restart in case of power failure Manual control for pump priming Level input detection Air temperature sensor Triggers relay to activate the recirculation pump to prevent water freezing in the pipes Configurable logging interval Real-time graph display Controller status, servicing, pump operation (dosing) LED indicators • Magnetic faceplate removal stops internal pump movement Front-facing wiring panel for easy accessibility USB port for logged data and firmware updates BL-135 model available with Analog Outputs (AO) Help section – overview of instrument’s main functionalities and features Programmable alarms Password protection Peristaltic chemical feed pump These controllers are equipped with a peristaltic dosing pump with replaceable chemical resistant tubing that is proportionally controlled with adjustable flow rates. Multi-coloured LED Indicators The controllers offer multiple LED indicators for status, servicing, and pump operation.

The STATUS LED changes colour based on operational state; a green LED means the water is within the desired parameter ranges, a yellow LED means that the controller needs attention, and a red LED identifies a problem in the system such as high/low alarms. The SERVICE LED indicates attention is required by a service technician. Automatic proportional pump control BL-135 features a proportionally controlled dosing pump.

The user can set the proportional band based on the sensitivity of the process. This setting determines the amount of time that the pumps are dosing as a percentage of the deviation from the set point. For example, a large body of water will use a small proportional band; having a small band (e.g., 0.1 pH) will ensure the pumps are dosing more often when the reading is close to the set point.

For smaller bodies of water such as hot tubs or spas, it is more useful to set a larger proportional band (e.g., 1.0 pH); when the reading is close to the set point, the amount of time that the dosing pump is on is minimal to avoid large swings of pH or ORP. This valuable feature allows for very fine control in maintaining the desired set point. Adjustable flow rate The dosing pump flow rate is adjustable from 0.5 to 3.5 L/h (0.13 to 0.92 gal/h).

Larger bodies of water require more chemical to be dosed than small bodies since it takes more chemical to see a change in the reading. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point. Automatic logging Measurement readings can be set at 30s/1m/5m/15m/30m/1h intervals.

A new log is started each time the instrument is calibrated when a setting is changed, or when a log becomes full. Logged data includes pH, ORP, salinity, chlorine, air and water temperature values, last calibration data, setup configuration, and any event data. Logs can be viewed on display in standard or plot mode and can be exported to USB flash drive in .CSV format.

Recall data displayed as a plot Options to zoom in 7 days or 6 hours Overview of measure range registered values (i.e. min, max, and average). USB connectivity Use the USB port to easily export data to a flash drive.

GLP Good Laboratory Practice (GLP) refers to a quality control function used to ensure uniformity of probe calibrations and measurements. GLP stores chlorine, pH, ORP, and salinity calibration information such as calibration points, date and time, and pH buffers used. Alarm system Programmable alarm system These controllers allow users to enable or disable the low and high level of alarms for all parameters: pH, ORP (mV), chlorine, salinity, and temperature.

When an alarm is activated, all dosing will stop. The alarm system also offers overdosing protection in that if the value is not corrected within a specified time interval, then the meter will go into alarm status. Hold input It is possible to connect a flow switch mounted in-line or a mechanical relay that is connected to the recirculation pump power source to the hold input of these controllers.

With no flow or when no power is applied to the recirculation pump, the hold circuit will disable the dosing pumps. This will prevent any dosing of chemical when there is no movement of water in the system. Analog outputs (BL-135 only) The BL-135 controller offer three 4-20 mA outputs.

Each output can be disabled or connected to an external recording device. Three measured parameters can be assigned to an analog output where the current signal will be proportional to the measured value. For more flexibility and better resolution, the analog output can be scaled; users can define any two points within a parameter range to correspond to the analog output span.

For example, the controller assigns 0 pH to 4 mA and 14 pH to 20 mA as a default. The user can adjust the pH range to assign pH 6 to 4 mA and pH 8 to 20 mA. This adjustment allows better resolution in the range of interest.

Safety features The flow control immediately stops continued chemical dosing when the flow through the chlorinator cell is stopped Chlorinator safety sensor - Monitors for gas entrapments, lack of water, low temperature, low salt pH safety devices - Overtime timers provide overfeed protection, crucial for shutting down acid or base feeding if pH sensor fails or recirculation system stops Programmable alarms Password protection - Restricted access to calibration, setup, and review of logged data Display modes The versatile display of these controllers allows for multiple display modes. The LCD can display all parameters, single parameter, chlorinator (cell status), or 24-hour plot screen with options for parameter selection and additional details. What's in the package?

Each BL-135-201XX is supplied with: BL130-7X0 Salt chlorinator BL130-415 Flow cell panel BL130-410 Flow cell for HI1040-1801 free chlorine probe (includes mounting brackets) HI-1040-1801 Free chlorine probe HI-1040A Replacement membrane cap for HI-1040-1801 free chlorine probe HI-7043S Gelled electrolyte for HI-1040-1801 free chlorine probe, 30 mL HI-1038-2802 Combined pH, ORP, salinity, temperature probe HI-7014 Free chlorine checker with reagent starter kit (6 tests) and sample cuvette (2 pcs.) BL130-900 Air temperature probe pH probe saddle for Ø 50 mm pipe Injector saddle for Ø 50 mm pipe Injector Valve for flow cell connection and fittings (2 pcs.) Valve saddle for Ø 50 mm pipe (2 pcs.) PVC tubing for aspiration and injection (5 m) Flow cell tubing (10 m) Peristaltic pump tubing Silicon oil (dropper bottle) Aspiration filter Cable gland gaskets (BL136 only) 4.01 and 7.01 pH buffer solution (3 sachets of each) 470 mV ORP test solution (3 sachets) 5.00 ppt salinity calibration standard (3 sachets) Power cable Quality certificates (instrument, probes, chlorinator, accessories) Quick reference guide with QR code for manual download

Specifications

ParameterValue
SKUBL-135-20110
pH
Range0.00 to 14.00 pH*
Resolution0.01 pH
Accuracy±0.05 pH (@ 25 °C / 77 °F)
CalibrationpH buffer: • Automatic buffer recognition • Two points (4.01 pH, 7.01 pH, 10.01 pH) • pH process: • Adjustable, single point
Temperature compensationAutomatic temperature compensation for pH (range: –5.0 to 105.0 °C / 23.0 to 221.0 °F
pH compensationAutomatic pH compensation for chlorine Range 6.0 to 8.0 pH*
ORP (mV)
Free chlorine
Salinity
Temperature
Air temperature
Data logging
Data logging memoryAutomatic logging of pH , ORP , salinity, chlorine, air and water- temperature measurements 300 days logging, depending on selected logging interval 100 lots (when memory is full, the new entry replaces the oldest data)
Data logging typeEvent type: setup, alarms, errors, warnings, calibration, power outage
Data logging intervalConfigurable logging interval: 30 seconds 1; 5; 15; 30; 60 minutes
Data logging export optionsExport to USB flash drive (USB-C port) in CSV format
Connectivity
RJ-45 (BL136 only)Ethernet connector (10/100 Mbps connection)
USB-CData export Software update
Additional specifications
pH controlUses pH measurement Delay to start at power on Proportional feed using adjustable set point and adjustable proportional band Dead band adjustable 0.01-0.20 pH (Technical Mode only) Overdose protection using the overfeed timer
Chlorinator controlUses chlorine measurement Programmable modes: - Boost Chlorine - Scheduled Boost - Pool Startup - Pool Cover Detect - Chlorine control AUTO, FIXED, Manual (On/Off)
Internal pump control0.5 to 3.5 L/h (0.13 to 0.92 gal/h) pump flow control 1 atm (14 psi) maximum output pressure Manual pump control Magnetic faceplate (covers the internal moving pump) triggers Hold status when removed and stops the pump
Pool Startup modeSimplified pool startup procedure Enabled or disabled manually from the controller menu Ensures 12 hour dosing cycle to reach a target setpoint Disabled automatically when setpoint is reached or the 12-hour timeout has expired
Pool Cover detectionReduced chlorine output when pool covered detected
Freeze Protection modeAir-temperature measurement triggers relay to activate the recirculation pump to prevent water freezing in the pipes
Boost chlorinationEnsures high-chlorine levels are produced in a short amount of time
Cold water protectionReduced chlorine output when pool water below 15 °C (59 °F)
GLPChlorine, pH, ORP, salinity
Meter password protectionPassword protected setup, calibration, and log recall
RelaysAlarm relay (SPDT) - Activated by selectable chlorine, pH, ORP, salinity, temperature alarm conditions Auxiliary Acid / Base pump relay (SPST) Recirculation pump relay (SPDT) All relays are fuse protected with 2A time delay 5× 20mm cartridge fuses. To be replaced only with time-delay glass/ceramic 5× 20mm cartridge fuse of same rating. All relays are rated for 250VAC / 30VDC 2A resistive load. Note: For inductive loads, an appropriate external snubber circuit must be connected to prevent relay contact damage.
Analog Outputs (BL135 only)3 × galvanic isolated, user configurable 4-20mA outputs Current sensing resistor ≤ 500 Ω Accuracy < 0.5 % FS
Digital inputs5 × galvanically isolated, powered contact, digital input Low level acid/base tank Hold mode Pool cover sensor Probe flow
Probes inputsHI-1038-2802 digital pH probe • pH, ORP, salinity, temperature sensors and a matching pin • IP65 connector • Galvanic isolated • RS485 interface HI-1040-1801 digital chlorine probe • Galvanic isolated • RS485 interface • IP65 connector • Air temperature sensor
Power
External
CasingWall mounted, IP65 rated, shockproof
Environment0 to 40 °C (32 to 104 °F) maximum 95 % RH non-condensing
Dimensions300×205×95 mm (11.8×8.07×3.7")
Weight4100 g (144.6 oz.)